CM602all_EJM8AESM_Service Manual - 第85页
* No connection to (2) above. Voltage 200V only * Connect the LAN cable (1). Select the data to be loaded beforehand. 64 Select "MC list. " Filer window 63 Check loading machine data from the PT. Main window Se…

[Outline]
CN01 CN00 CN01 CN00
CN00: connects the previous machine
CN01: connects the next machine.
60
Connect the connection cables (signal) CN00 and CN0
1
For signal connection, see separate spec.
* Various signals are used; the standard is shown below:
59
"High-speed" Setup windo
w
"Multi-purpose" Setup windo
w
Set (3) Acceptable recog rate to 85%
.
Set (4) Acceptable recog rate to 85%
.
58
Set the recognition judgment valu
e
Select (1) Machine parameter Select (2) Judgment value
57
Display of the panel selected
Display of the panel non-selecte
d
[Judgment]
The "SELECT"-side lamp
should be ON.
Installation Machine Installation
Item Remark
(1)
(2)
Machine 1 Machine 2 Machine 3
Board flow
EJM8A-E-SMA020103-A01-00 Page 2-1-3-16

* No connection to (2) above.
Voltage 200V only
* Connect the LAN cable (1).
Select the data to be
loaded beforehand.
64
Select "MC list.
"
Filer window
63
Check loading machine data from the PT.
Main window
Select "Filer."
[Danger]
Be sure to turn off the
factory's electric source
before checking
connection.
Even though the machine
is turned off, the HUB 200V
is always connected.
Item Remark
61
Check the HUB power and the communication cable for connection. For the receptacle
position, see the right picture below. From Hub to the circuit protector in Step 6
2
Installation Machine Installation
62
Connect to the circuit protector.
(1)
(2)
EJM8A-E-SMA020103-A01-00 Page 2-1-3-17

Details of the selected data is displayed.
RemarkItem
Installation Machine Installation
65
"Machine List Entry" windo
w
Select "Select Entry File(S).
"
66
"Machine List Entry" windo
w
Select data from the list box Select "Group", "Lot" and "Machine.
"
67
"Machine List Entry" window
Select "Refresh PT File List (S).
"
"Machine List Entry" window
68
Select machine data from module 1.
The data version is
displayed here.
EJM8A-E-SMA020103-A01-00 Page 2-1-3-18