User Manual - SIPLACE Glue Feedeer - 第28页
3 Initial Operation 3.3 Connecting the Glue Feeder to the Safety Circuit 28 User Manual SIPLACE Glue Feeder 05/2020 3.3 Connecting the Glue Feeder to the Safety Circuit NOTICE Connection to safety circuit already present…

3 Initial Operation
3.2 Positioning/Removing the Glue Feeder
User Manual SIPLACE Glue Feeder 05/2020 27
Removing the Glue Feeder
► Press the release handle (1) under the status dis-
play LED (2)
at the rear end of the Glue Feeder.
The log off procedure is started for the Glue Feeder, the status display is switched off and the
removal handle will protrude. All key data will be saved in the Glue Feeder. The Glue Feeder will
then be automatically logged off the FCU and the FCU will open the mechanical lock at the loca-
tion. As soon as the status displays are dark, the log off procedure has been completed.
► Now use the removal handle to pull the feeder module out of the location.
NOTICE
Repeating log on and off
If you wait for too long when removing the Glue Feeder (> approx 5 seconds), the status
display will shine red and you will need to log the Glue Feeder back on again.
► Press the removal handle in the Glue Feeder.
The log on procedure for the Glue Feeder will start.
► Wait until the log on procedure is completed and the status display lights up green.
► Press the removal handle at the rear end of the Glue Feeder again and then pull the
Glue Feeder out of the location, as soon as the status display extinguishes.

3 Initial Operation
3.3 Connecting the Glue Feeder to the Safety Circuit
28 User Manual SIPLACE Glue Feeder 05/2020
3.3 Connecting the Glue Feeder to the Safety Circuit
NOTICE
Connection to safety circuit already present?
If the machine does not yet have a connection to the safety circuit, you will need to fit this
first. You will find a retrofit description in the appropriate retrofit kit for your machine.
The integration of the Glue Feeder into the safety circuit of the machine ensures that, when the
machine cover is open, the Glue Feeder can only dispense glue if the safety cover is fitted correctly
into place on the jet valve. This is an important safety measure which safeguards the operator from
being hit by a shot of glue and injured.
Connecting the safety circuit
► Plug the connector from the safety circuit into the
connection shown in the diagram.
Make sure that the red dot on the connector and
the red dot on the connection are in line (one
above the other).
Disconnecting the safety circuit
► To disconnect the Glue Feeder form the safety
circuit, grip the removal ring on the LEMO con-
nector, as marked in the diagram, and pull the
connector down and off.

3 Initial Operation
3.4 Connecting the Glue Feeder to the Compressed Air Supply
User Manual SIPLACE Glue Feeder 05/2020 29
3.4 Connecting the Glue Feeder to the Compressed Air
Supply
NOTICE
Connection to compressed air supply already present?
If the machine does not yet have a connection to the compressed air supply, you will need
to fit this first. You will find a retrofit description in the appropriate retrofit kit for your
machine.
The external compressed air supply is linked to the Glue Feeder using a quick-change coupling.
Connecting the compressed air supply
► Connect the quick-change coupling for the com-
pressed air supply to the connection shown in the
diagram.
Disconnecting the compressed air supply
CAUTION
Risk of injury from compressed air
Risk of injury when disconnecting the compressed air lines.
► Never disconnect the compressed air supply while it is still pressurized.
► To disconnect the Glue Feeder from the com-
pressed air supply, grip the safety ring on the
quick-change coupling, as shown in the diagram,
and pull the coupling down and off.