3 Initial Operation 3.4 Connecting the Glue Feeder to the Compressed Air Supply User Manual SIPLACE Glue Feeder 05/2020 29 3.4 Connecting the Glue Feeder to the Compressed Air Supply NOTICE Connection to compressed air s…

3 Initial Operation
3.3 Connecting the Glue Feeder to the Safety Circuit
28 User Manual SIPLACE Glue Feeder 05/2020
3.3 Connecting the Glue Feeder to the Safety Circuit
NOTICE
Connection to safety circuit already present?
If the machine does not yet have a connection to the safety circuit, you will need to fit this
first. You will find a retrofit description in the appropriate retrofit kit for your machine.
The integration of the Glue Feeder into the safety circuit of the machine ensures that, when the
machine cover is open, the Glue Feeder can only dispense glue if the safety cover is fitted correctly
into place on the jet valve. This is an important safety measure which safeguards the operator from
being hit by a shot of glue and injured.
Connecting the safety circuit
► Plug the connector from the safety circuit into the
connection shown in the diagram.
Make sure that the red dot on the connector and
the red dot on the connection are in line (one
above the other).
Disconnecting the safety circuit
► To disconnect the Glue Feeder form the safety
circuit, grip the removal ring on the LEMO con-
nector, as marked in the diagram, and pull the
connector down and off.

3 Initial Operation
3.4 Connecting the Glue Feeder to the Compressed Air Supply
User Manual SIPLACE Glue Feeder 05/2020 29
3.4 Connecting the Glue Feeder to the Compressed Air
Supply
NOTICE
Connection to compressed air supply already present?
If the machine does not yet have a connection to the compressed air supply, you will need
to fit this first. You will find a retrofit description in the appropriate retrofit kit for your
machine.
The external compressed air supply is linked to the Glue Feeder using a quick-change coupling.
Connecting the compressed air supply
► Connect the quick-change coupling for the com-
pressed air supply to the connection shown in the
diagram.
Disconnecting the compressed air supply
CAUTION
Risk of injury from compressed air
Risk of injury when disconnecting the compressed air lines.
► Never disconnect the compressed air supply while it is still pressurized.
► To disconnect the Glue Feeder from the com-
pressed air supply, grip the safety ring on the
quick-change coupling, as shown in the diagram,
and pull the coupling down and off.

3 Initial Operation
3.5 Predosing the Glue Feeder
30 User Manual SIPLACE Glue Feeder 05/2020
3.5 Predosing the Glue Feeder
The aim of this task is to distribute the glue in the feed pipe, jet block and dispenser nozzle on
setup or after cleaning and to also make sure that there is no air left in these parts.
NOTICE
Pressure set?
Before you begin with the predosing, check that the pressure at the cartridge and at the jet
valve has been correctly set (see section 2.2.5
"Overview of Glues" [}16] and section4.3.1
"Setting the Pressure Reducer" [}63]).
Also observe the Technical Information TI2015-05E11 "Maintenance and production pre-
paration tips for the Glue Feeder".
Equipment required
●
Safety cover
(The new version of the safety cover is made of black metal)
●
8mm paper tape
► Push the paper tape into the safety cover as
shown in the diagram.
► Open the machine hood.
► Push the gantry back.