3 Initial Operation 3.6 Deaerating 32 User Manual SIPLACE Glue Feeder 05/2020 3.6 Deaerating On initial setup, when first using a fully cleaned Glue Feeder or after replacing a cartridge, check the functionality of the G…

100%1 / 96
3 Initial Operation
3.5 Predosing the Glue Feeder
User Manual SIPLACE Glue Feeder 05/2020 31
Position the safety cover over the dispenser
nozzle of the Glue Feeder, as shown in the dia-
gram.
This automatically activates the nozzle heating.
After reaching the set nominal temperature, the
Glue Feeder will start a waiting period of
25seconds, to ensure that the glue in the jet
block has been fully warmed through. During the
waiting period, the display will flash the current
temperature.
Predosing is only possible after this waiting
period.
Press the front arrow button to release a glue dot
(shot of glue).
Short press = 1 drop
Long press = 20 drops
Normally 3x20 drops are sufficient.
Remove the safety cover and check the glue dot.
NOTICE
Actual temperature does not change?
If the displayed actual temperature does not change, check whether the safety cover has
been correctly fitted.
The glue dot should be round and with no satellite formation. If it is not, move the paper tape in the
safety cover and repeat the procedure.
If the result is in the required range, you can use the component shape teach mode to pick up a
component, apply glue to it and check it with SIPLACE Vision. If all the settings are correct, test the
placement program on a test board.
To check whether the volume of glue applied is enough or to make sure that it is not too large, you
can carefully lift the glued components off the test board with a pair of tweezers. If the glue coating
on the board is as you expected, you can start production operations.
If you want to use the glue at the same time as solder paste, the test board should also have solder
paste applied to it. This is the only way to check whether the height of the glue dot is enough to
coat the board.
3 Initial Operation
3.6 Deaerating
32 User Manual SIPLACE Glue Feeder 05/2020
3.6 Deaerating
On initial setup, when first using a fully cleaned Glue Feeder or after replacing a cartridge, check
the functionality of the Glue Feeder.
It is normally enough to follow the procedure described in section 3.5 "Predosing the Glue
Feeder" [}30], activate 3x the dosage of 20drops with a "long press" of the front arrow button, to
get the first amount of adhesive out of the nozzle.
However, even after the first dispensing, there might still be air bubbles in the system, so that it
should then be "deaerated".
Procedure
The main procedure is very similar to that described in section 4.2.6 "Applying Glue for Test-
ing" [}58].
Instead of the relatively short paper tape, now use an approx. 30 cm long piece of paper tape as a
test strip.
Insert the test strip into the safety cover, as shown.
Proceed as described in section 4.2.6 "Applying Glue for Testing" [}58].
In the dialog Dispense set the number of glue dots to 200.
In the same dialog, set the cycle time to the value you then want to use for your production.
Click on Start and slowly and evenly pull the test strip through the safety cover.
Remove the test strip.
Check whether there are glue dots missing on the test strip.
If more than 5 glue dots are missing or if several are missing at the end of the test strip, repeat this
procedure with a new test strip each time, until all 200 glue dots can be seen on the test strip.
The system is then deaerated and you can start the production process.
4 Operation
4.1 Settings in SIPLACE Pro 10.1 and Higher
User Manual SIPLACE Glue Feeder 05/2020 33
4 Operation
4.1 Settings in SIPLACE Pro 10.1 and Higher
In order to process components with the Glue Feeder, you need to perform the following preparat-
ory steps:
Define a model of the glue dots for each component (component shape).
You define the position and size of one or more glue dots which you want to use to fix the
component to the board.
Activate Gluing in the object properties for the component.
This is a global setting which specifies whether the component may be glued during place-
ment or not.
Activate Gluing in the placement list.
Any one component can occur multiple times on a single board. This is where you define in
the placement list the positions on the board at which a component is to be glued and those
positions at which a component should not be glued.
NOTICE
Avoid contact with the dispenser nozzle
To prevent contact with the dispenser nozzle or excessive distance to the component, de-
scribe the height of the component (overall height with leads and tolerances) as precisely
as possible.