User Manual - SIPLACE Glue Feedeer - 第5页

1 Introduction 1.1 Safety instructions User Manual SIPLACE Glue Feeder 05/2020 5 1 Introduction This manual provides technical information and describes how to operate the SIPLACE® Glue Feeder. 1.1 Safety instructions DA…

100%1 / 96
4 User Manual SIPLACE Glue Feeder 05/2020
Contents
4.1.1 Defining a Component Shape Glue Dot Model.. 34
4.1.2 Enabling/Disabling Gluing in the Component Object Properties.. 38
4.1.3 Enabling Gluing in the Placement List.. 40
4.1.4 Setting up the Glue Feeder.. 42
4.2 Individual Functions in Stations Software 706.1 and Higher.. 45
4.2.1 Measuring Dispenser Nozzle Position.. 45
4.2.2 Manually Opening Measurement of Dispenser Nozzle Position.. 46
4.2.3 Checking and Teaching Component Shapes and Glue Dot Inspections.. 48
4.2.4 Setting the Temperature.. 51
4.2.5 Managing Parameter Sets.. 55
4.2.5.1 Editing Parameter Sets.. 57
4.2.6 Applying Glue for Testing.. 58
4.3 Manual Settings.. 63
4.3.1 Setting the Pressure Reducer.. 63
4.3.2 Setting the Glue Temperature.. 64
4.3.3 Calibrating the temperature regulation.. 64
5 Cleaning and Maintenance.. 67
5.1 Maintenance Kit.. 67
5.2 Equipment Required.. 68
5.3 Maintenance Overview.. 69
5.4 Cleaning and Inspecting the Gluing Unit.. 70
5.4.1 Dismantling the Gluing Unit.. 70
5.4.1.1 Removing the Cartridge.. 70
5.4.1.2 Removing the Nozzle Heating.. 72
5.4.1.3 Removing the Dispenser Nozzle.. 73
5.4.1.4 Removing the Cartridge Pipe.. 73
5.4.1.5 Removing the Jet Block.. 74
5.4.1.6 Removing the O Rings.. 74
5.4.2 Cleaning the Gluing Unit.. 75
5.4.2.1 Preparing the Syringe.. 75
5.4.2.2 Cleaning the Jet Block.. 76
5.4.2.3 Cleaning the Cartridge Pipe.. 76
5.4.2.4 Cleaning the Dispenser Nozzle.. 77
5.4.2.5 Rinsing/Ultrasound Bath.. 78
5.4.2.6 Drying.. 78
5.4.2.7 Cleaning the Syringe.. 79
5.4.3 Fitting the Gluing Unit.. 79
5.4.3.1 Inserting the O Rings at the Plunger.. 79
5.4.3.2 Fastening the Jet Block.. 80
5.4.3.3 Attaching the Cartridge Pipe.. 81
5.4.3.4 Fitting the Dispenser Nozzle.. 81
5.4.3.5 Fastening the Nozzle Heating.. 82
5.4.3.6 Inserting the Cartridge.. 83
5.5 Replacing the Cartridge.. 85
5.5.1 Removing the Cartridge.. 85
5.5.2 Inserting the Cartridge.. 86
5.6 Guide Bushing and Actuator O-Ring.. 88
5.6.1 Removing the Actuator O-Ring and Guide Bushing.. 88
5.6.2 Inserting the Actuator O-Ring and Guide Bushing.. 91
6 Troubleshooting .. 93
1 Introduction
1.1 Safety instructions
User Manual SIPLACE Glue Feeder 05/2020 5
1 Introduction
This manual provides technical information and describes how to operate the SIPLACE® Glue
Feeder.
1.1 Safety instructions
DANGER
Nonobservance of these safety instructions may cause injury to personnel and dam-
age to the machine!
Please observe the safety instructions in the user manual of the relevant machine
for all work!
1.1.1 Conventions for the use of safety instructions and symbols
Safety instructions
This manual contains notes that must be observed to guarantee your personal safety and to avoid
damage to equipment. These notes are highlighted by warning triangles and are indicated as fol-
lows according to the level of risk:
DANGER
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or considerable
damage to property will occur if this hazard warning is not observed.
WARNING
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or considerable
damage to equipment may occur if these warning instructions are not followed.
CAUTION
Definition
For the purposes of this manual, this indicates that minor injuries or damage to property
may occur if this caution is not observed.
NOTICE
Definition
For the purposes of this manual, this note provides information about the product or indic-
ates a part of the manual that requires particular attention.
Symbols
Example Description
Next This typeface marks controls and interface elements in the software.
This symbol indicates actions that have to be performed by the operator.
1 Introduction
1.2 Operational Safety
6 User Manual SIPLACE Glue Feeder 05/2020
1.1.2 Safety instructions for the compressed air supply
CAUTION
Risk of injury from compressed air!
Risk of injury when disconnecting the compressed air lines.
Never disconnect compressed air lines while they are still pressurized.
CAUTION
Prolonged interruptions to the compressed air supply can cause damage.
When the machine is switched on, do not use the shutoff valve to interrupt the compressed
air supply for more than 30 minutes.
If you need to shut off the compressed air system for longer in order to carry out your
work, you must switch the machine off at the main switch and disconnect it from the
power supply.
1.1.3 Safety instructions on hazardous materials
CAUTION
Observe the safety data sheets
Observe the applicable safety data sheet, when handling hazardous materials (e. g. Loctite
241, ethanol).
1.2 Operational Safety
1.2.1 Warning Labels
Hot surface warning
Always wear protective goggles when in the vicinity of the Glue
Feeder.