4 Operation
4.3 Manual Settings
64 User Manual SIPLACE Glue Feeder 05/2020
4.3.2 Setting the Glue Temperature
The value last set is always saved in the glue feeder.
To edit a setting, proceed as follows:
► Press the gray button (1), to access the Setting
the Temperature submenu.
"tE" will be shown in place of the actual temperat-
ure (6)
.
► Use the arrow keys (3, 4) to set the required
nominal temperature. Each press of the key
changes the nominal temperature by one degree.
The back arrow key (3) lowers the value.
The front arrow key (4)
increases the value.
The back display (5) shows the target value which you
are currently setting.
The front display (6)
shows the current temperature of
the glue.
► Press the yellow button (2), to save the set value.
The set temperature is sent to the machine.
4.3.3 Calibrating the temperature regulation
Due to different absolute values, the measuring resistance may vary within the permissible toler-
ances and the values shown on the individual Glue Feeders could deviate (offsets). To ensure that
measurement is more precise and uniform, the calibration of the Glue Feeders determines an indi-
vidual compensation value for each Glue Feeder and stores this.
NOTICE
Calibration recommended
To enable you to use uniform temperature profiles for the various adhesives required for
multiple Glue Feeders in the same production environment, we recommend calibrating the
individual Glue Feeders with the Glue Feeder calibration device (item no. 03214618-xx).
Performing the calibration
ü The Glue Feeder is located on an X FCU or a single slot EDIF (SSE).
ü The feeder module must still be de-energized. This means:
do not fully insert a feeder module into an X-FCU.
The power supply must be switched off on a SSE.
NOTICE
Only connect and disconnect the heating cable when de-energized!
The heating cable may not be connected to or disconnected from the nozzle heating or the
calibration device when energized. Make sure that the Glue Feeder is de-energized before
connecting or disconnecting!
ü When using the calibration device, you need at least the embedded software (eSW) applica-
tion version1.02 at the SIPLACE Glue Feeder.
► Disconnect the heating cable from the nozzle heating.
► Connect the heating cable to the calibration device.
NOTICE
Selecting the correct connection on the calibration unit
The calibration device has 2 connection options: the socket fits an older version of the heat-
ing cable. The plug fits to a newer version of the heating able. (The diagram shows the
newer version of the heating cable.)

4 Operation
4.3 Manual Settings
User Manual SIPLACE Glue Feeder 05/2020 65
Fig.3: Connecting the calibration device
► Switch the Glue Feeder on:
Push the Glue Feeder into the X-FCU or switch the power supply on for the SSE.
ð The calibration is started and performed automatically by the eSW.
The status display at the back end of the feeder modules will flash alternatively green and
orange, when the calibration has finished.
While the calibration is still in progress or as long as the calibration device is attached to
the heating cable, the eSW will not continue with normal operations.
► Switch the Glue Feeder off again:
If using an X-FCU, pull the Glue Feeder back again from the FCU or, if using an SSE, switch
the power supply of the SSE off.
► Unplug the heating cable from the calibration device and reconnect it to the nozzle heating.
ð The calibration sequence has been completed and you can use the Glue Feeder for nor-
mal operation again.

4 Operation
4.3 Manual Settings
66 User Manual SIPLACE Glue Feeder 05/2020