User Manual SIPLACE Glue Feeder 05/2020 71
Press the cartridge adapter towards the back and
pull it off.
Unscrew the cartridge from the cartridge pipe
thread.
5 Cleaning and Maintenance
5.4 Cleaning and Inspecting the Gluing Unit
72 User Manual SIPLACE Glue Feeder 05/2020
5.4.1.2 Removing the Nozzle Heating
Unplug the heating connector from the nozzle
heating.
Position the two lugs of the heating key into the
two holes in the union nut.
Loosen the union nut by turning it anticlockwise.
Remove the union nut.
Remove the nozzle heating.
5 Cleaning and Maintenance
5.4 Cleaning and Inspecting the Gluing Unit
User Manual SIPLACE Glue Feeder 05/2020 73
5.4.1.3 Removing the Dispenser Nozzle
NOTICE
Flat nozzle and needle nozzle
Depending upon its purpose, the glue feeder can be used with either a flat or needle
nozzle. The procedure for removing the dispenser nozzle is the same in both types and is
illustrated using the example of the flat nozzle in the following section:
Lift the dispenser nozzle off the jet block.
5.4.1.4 Removing the Cartridge Pipe
Hold the cartridge pipe tight with one hand.
Loosen the screwed connection with the help of
an 8 mm open-ended wrench.
Remove the cartridge pipe.