User Manual - SIPLACE Glue Feedeer - 第83页

5 Cleaning and Maintenance 5.4 Cleaning and Inspecting the Gluing Unit User Manual SIPLACE Glue Feeder 05/2020 83 5.4.3.6 Inserting the Cartridge Two sizes of cartridge can be used with the Glue Feeder (10 or 30 ml). ► A…

100%1 / 96
5 Cleaning and Maintenance
5.4 Cleaning and Inspecting the Gluing Unit
82 User Manual SIPLACE Glue Feeder 05/2020
5.4.3.5 Fastening the Nozzle Heating
Place the nozzle heating onto the jet block and
align this straight on the cartridge pipe.
Fit the union nut onto the dispenser nozzle.
Position the two lugs of the heating key into the
two holes in the union nut.
Tighten the union nut by turning it clockwise.
Insert the heating connector into the nozzle heat-
ing, up to the stop.
5 Cleaning and Maintenance
5.4 Cleaning and Inspecting the Gluing Unit
User Manual SIPLACE Glue Feeder 05/2020 83
5.4.3.6 Inserting the Cartridge
Two sizes of cartridge can be used with the Glue
Feeder (10 or 30 ml).
Adjust the cartridge holder to the size of the cart-
ridge to be used.
1. Then pull out the cartridge holder.
2. Turn the cartridge holder so that the required size
is at the top.
3. Let the cartridge holder engage audibly.
Screw the front cap off the cartridge.
Remove the back cap from the cartridge.
Hold the cartridge against the cartridge pipe and
screw it on to the pipe straight.
5 Cleaning and Maintenance
5.4 Cleaning and Inspecting the Gluing Unit
84 User Manual SIPLACE Glue Feeder 05/2020
Fit the cartridge adapter at the straight points
onto the back of the cartridge and press on as far
as the stop.
Turn the cartridge adapter clockwise as far as the
stop.
Make sure that the O-ring on the cartridge adap-
ter is completely flush against the inside of the
cartridge and seals it. If not, the required working
pressure will not form.
To make it easier to insert the adapter with the
O‑ring, you can grease the O-ring slightly (Tur-
motemp II/400 CL2).
NOTICE
Predosing
Although you have inserted the cartridge, the Glue Feeder is still not ready for use. You first
need to position the Glue Feeder at the required location and predose the glue unit (cart-
ridge pipe, jet block and dispenser nozzle) i.e. fill it with glue. For a detailed description,
refer to section 3.5
"Predosing the Glue Feeder" [}30].