FUJI错误代码查询 - 第169页
Code: 11022A03 Display: 11022A03 Used by: QP132 Cause: The program origin y coordinate for mark reading was not input. Remedy: Specify the correct data for 142. Mark Read Position MYC in Proper data. --------------------…
Remedy: Specify the X2 axis plus movement range in Proper data item
136.Max_Limit_Position_X2 for the FLT and
146.Max_Limit_Position_X2 for the FIP3.
------------------------------
Code: 11022914
Display:
Used by: IP3
Cause: The Y axis plus movement range has not been specified.
Remedy: Specify the Y axis plus movement range in Proper data item
137.Max_Limit_Position_Y for the FLT and
147.Max_Limit_Position_Y for the FIP3.
------------------------------
Code: 11022915
Display:
Used by: IP3
Cause: The X1 axis plus movement range has not been specified.
Remedy: Specify the X1 axis plus movement range in Proper data item
143.Max_Limit_Position_X1 for the FLT and
152.Max_Limit_Position_X1 for the FIP3.
------------------------------
Code: 11022916
Display:
Used by: IP3
Cause: RCU line port setting is out of range.
Remedy: Input a value into Proper data's 158.RCU_line_Port setting.
------------------------------
Code: 11022917
Display:
Used by: IP3
Cause: The RCU line port was previously set to a different setting.
Remedy: Input a correct value into Proper data's 158.RCU_line_Port setting.
------------------------------
Code: 11022A00
Display: 11022A00
Used by: QP132
Cause: The RB servo communication port number is not specified.
Remedy: Specify the correct data for 110. Servo Control Port No. in Proper data. When connecting to the
second VM 1440 board, channel 1 is 17, 2 is 18, etc (17 is input when shipped)
------------------------------
Code: 11022A01
Display: 11022A01
Used by: QP132
Cause: The offset value between boards was not input for operation with multiple boards in one pallet.
Remedy: Specify the correct data for 125. PCB Setup tolerance in Proper data.
------------------------------
Code: 11022A02
Display: 11022A02
Used by: QP132
Cause: The program origin x coordinate for mark reading was not input.
Remedy: Specify the correct data for 141. Mark Read Position MXC in Proper data.
------------------------------
第 168 页
Code: 11022A03
Display: 11022A03
Used by: QP132
Cause: The program origin y coordinate for mark reading was not input.
Remedy: Specify the correct data for 142. Mark Read Position MYC in Proper data.
------------------------------
Code: 11022A04
Display: 11022A04
Used by: QP132
Cause: The coordinates of the F-axis origin for the feeder check were not input.
Remedy: Specify the correct data for 122. Feeder Check Origin F0 in Proper data.
------------------------------
Code: 11022A05
Display: 11022A05
Used by: QP132
Cause: The coordinates of the SS-axis origin were not input.
Remedy: Specify the correct data for 143. Step Slide Origin SS0 in Proper data.
------------------------------
Code: 11022A06
Display: 11022A06
Used by: QP132
Cause: The coordinates of the PI-axis origin were not input.
Remedy: Specify the correct data for 124. PCB Setup Position PI in Proper data.
------------------------------
Code: 11022A07
Display: 11022A07
Used by: QP132
Cause: The coordinates of the PO-axis origin were not input.
Remedy: Specify the correct data for 125. PCB Unload Position PO in Proper data.
------------------------------
Code: 11022A08
Display: 11022A08
Used by: QP132
Cause: The pulse count for the MX-axis minus direction limit was not set.
Remedy: Specify the correct data for 168. Min Limit Position MX in Proper data.
------------------------------
Code: 11022A09
Display: 11022A09
Used by: QP132
Cause: The pulse count for the MY-axis plus direction limit was not set.
Remedy: Specify the correct data for 163. Max Limit Position MY in Proper data.
------------------------------
Code: 11022A0A
Display: 11022A0A
Used by: QP132
Cause: The pulse count for the SS-axis plus direction limit was not set.
Remedy: Specify the correct data for 164. Max Limit Position SS in Proper data.
------------------------------
Code: 11022A0B
Display: 11022A0B
Used by: QP132
第 169 页
Cause: The pulse count for the PI-axis plus direction limit was not set.
Remedy: Specify the correct data for 143. Max Limit Position PI in Proper data.
------------------------------
Code: 11022A0C
Display: 11022A0C
Used by: QP132
Cause: The pulse count for the PO-axis plus direction limit was not set.
Remedy: Specify the correct data for 166. Max Limit Position PO in Proper data.
------------------------------
Code: 11022A0D
Display: 11022A0D
Used by: QP132
Cause: The pulse count for the F-axis plus direction limit was not set.
Remedy: Specify the correct data for 145. Max Limit Position F in Proper data.
------------------------------
Code: 11022A0E
Display: 11022A0E
Used by:
Cause: The X-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 520: [PM] Zero Setup Speed X is set. If not, input correct data.
------------------------------
Code: 11022A0F
Display: 11022A0F
Used by:
Cause: The Y-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 521: [PM]Zero Setup Speed Y was set. If not, input correct
data.
------------------------------
Code: 11022A11
Display: 11022A11
Used by:
Cause: The Z-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 522: [PM] Zero Setup Speed Z was set. If not, input correct
data.
------------------------------
Code: 11022A12
Display: 11022A12
Used by:
Cause: The creep speed for X-axis servo zero setting was not specified in the common PM Proper data.
Remedy: Confirm that the Proper data item 524: [PM] Creep Speed X was set. If not, input correct data.
------------------------------
Code: 11022A13
Display: 11022A13
Used by:
Cause: The creep speed for Y-axis servo zero setting was not specified in the common PM Proper data.
Remedy: Confirm that the Proper data item 525: [PM] Creep Speed Y was set. If not, input correct data.
------------------------------
Code: 11022A15
Display: 11022A15
Used by:
Cause: The creep speed for Z-axis servo zero setting was not specified in the common PM Proper data.
第 170 页