FUJI错误代码查询 - 第105页

Code: 1101D099 Display: Same as code Used by: IP2 Cause: A pre-rotation setting is included in the device data for a device using a rectangular nozzle. Pre- rotation cannot be performed by an IP2 using a rectangular nozz…

100%1 / 5282
------------------------------
Code: 1101D092
Display:
Used by: IP3
Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This
applies to sequences 101 to 300.
Remedy: Check the setting in Package_and_appearance_data's 21.(Tray:)Tray_pickup_pnt_y.
------------------------------
Code: 1101D093
Display:
Used by:
Cause: A pickup point from which to pick an empty tray (to be ejected) has not been specified. This
applies to sequences 301 to 500.
Remedy: Check the setting in Package_and_appearance_data's 21.(Tray:)Tray_pickup_pnt_y.
------------------------------
Code: 1101D094
Display:
Used by: IP3
Cause: The vision processing system's vision type has not been specified. This applies to sequences 1 to
50.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D095
Display:
Used by:
Cause: The vision processing system's vision type has not been specified. This applies to sequences 51
to 100.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D096
Display:
Used by:
Cause: The vision processing system's vision type has not been specified. This applies to sequences 101
to 300.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D097
Display:
Used by:
Cause: The vision processing system's vision type has not been specified. This applies to sequences 301
to 500.
Remedy: Check Part data's Vision_data 14.Vision_type.
------------------------------
Code: 1101D098
Display: 1101D098
Used by: IP3
Cause: The length of the pin on the bottom of the part for which flux is to be applied has been specified
in Alignment_pin_length. This error has occurred because of the risk of interference during the flux
application, between the bottom of the flux receptacle and the pin on the bottom of the part.
Remedy: After correcting the part data item in question, transmit the production program again.
------------------------------
第 104 页
Code: 1101D099
Display: Same as code
Used by: IP2
Cause: A pre-rotation setting is included in the device data for a device using a rectangular nozzle. Pre-
rotation cannot be performed by an IP2 using a rectangular nozzle.
Remedy: The pre-rotation setting in the device data will be ignored when a rectangular nozzle is used. To
use pre-rotation, change the nozzle.
------------------------------
Code: 1101D09A
Display: Same as code
Used by: IP2
Cause: A 90[deg] rotation pickup setting is included in the device data for a device using a rectangular
nozzle. A 90[deg] rotation pickup cannot be performed by an IP2 using a rectangular nozzle.
Remedy: The 90[deg] rotation pickup setting in the device data will be ignored when a rectangular nozzle
is used. To use the 90[deg] rotation pickup function, change the nozzle.
------------------------------
Code: 1101D09B
Display: Same as code
Used by: IP2
Cause: A lead coplanarity check setting is included in the device data for a device using a rectangular
nozzle. A lead coplanarity check cannot be performed by an IP2 using a rectangular nozzle.
Remedy: The lead coplanarity check setting in the device data will be ignored when a rectangular nozzle is
used. To use the lead coplanarity check function, change the nozzle.
------------------------------
Code: 1101D09C
Display: Same as code
Used by:
Cause: The value of the "Package_and_appearance_data:Tray_pick_pnt_x_IP" parameter in the Part data
has exceeded the remover's movement range in the X-axis direction. This error occurs in devices 101
through 120.
Remedy: Set this parameter to a value from -1 to -125.
------------------------------
Code: 1101D09D
Display: Same as code
Used by:
Cause: The value of the "Package_and_appearance_data:Tray_pick_pnt_y_IP" parameter in the Part data
has exceeded the remover's movement range in the Y-axis direction. This error occurs in devices 101 to
120.
Remedy: Set this parameter to a value from -1 to -250.
------------------------------
Code: 1101D1??
Display: Same as code
Used by: IP1
Cause: A value input for the notch check coordinates has exceeded the valid range (on the FIP-1 or -2).
The value replacing the "??" in the code is the device number.
Remedy: Make sure that values from -12.7 to 12.7 [mm] have been set for these Part data parameters:
"Fst_pin_check_data", "3.Fst_pin_check_area_x1", and "4.Fst_pin_check_area_y1".
------------------------------
Code: 1101D200
Display: 不是joint模式时、不能在供料器安装数据中进行供料平台2的设定。
Used by: XP141,XP142
第 105 页
Cause: 不是joint模式时,不能在供料器安装数据中进行供料平台2的设定。
Remedy: 请删除供料器平台2的供料器数据。
------------------------------
Code: 1101D201
Display: 未找到元件数据。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 不存在对应于元件号码的数据。
Remedy: 请创建指定的元件号码的数据或指定所存在的元件号码。
------------------------------
Code: 1101D202
Display: 次料站No.必须设定为其他供料器。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 料站No.和次料站No.相同。
Remedy: 请设定与料站No.不同的次料站No.。
------------------------------
Code: 1101D203
Display: 将未分配元件号码的料站设定为次料站。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 将未分配元件号码的料站设定为次料站。
Remedy: 请将同名的元件号码所指定的料站No.设定为次料站No.。
------------------------------
Code: 1101D204
Display: 在次料站中指定的料站与元件号码不同。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 将设定成不同元件号码的料站No.设定为次料站No.。
Remedy: 请将设定成同名的元件号码的料站No.设定为次料站No.。
------------------------------
Code: 1101D205
Display: 供料平台No./料站No.和元件数据的 Packaging Type 不相配。
Used by: XP241,XP142,XP242
Cause: 在用于供料器的供料平台No./料站No.上Packaging Type设定为具有Tray的Packaging数据的元件号码,或
在用于Tray的供料平台No./料站No.上设定为不是Tray的Packaging数据的元件号码。
Remedy: 请在用于供料器的供料平台No./料站No.上将Packaging Type设定为具有Tray以外的Packaging数据的元
件号码。请在用于Tray的供料平台No./料站No.上将Packaging Type设定为具有Tray的Packaging数据的元件号码。
------------------------------
Code: 1101D206
Display: 次料站没有形成回路。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 次料站No.没有构成回路。
Remedy: 请将次料站No.设定为回路结构。
------------------------------
Code: 1101D207
Display: 在供料器安装数据中设定了不存在的供料平台。
Used by: XP142
Cause: 是单侧供应元件的选项机器,在供料器安装数据中被设定在供料平台2上。
Remedy: 请将供料平台2的供料器数据清除或将移动到供料平台1上。
------------------------------
Code: 1101D208
Display: 在顺序数据的料站No.上,设定了次供料器设定内的几个料站。
Used by: XP142,XP242
Cause: 在次供料器设定内,存在几个初始的料站。
第 106 页