FUJI错误代码查询 - 第1105页

Display: Package unclamping error! Used by: QP301 Cause: The ON or OFF signal for the package unclamper timed out. Remedy: Check for interference with the package unclamper. ------------------------------ Code: 15026007 …

100%1 / 5282
Remedy: Check that there is no load on the cylinder. Also check the sensor signal at the I/O map.
------------------------------
Code: 15024003
Display: (Differs according to the machine.)
Failed to arrive at target position.(NP2,QP3)
Used by:
Cause: Board delivery time up error.
The specified time for the monitoring of the clearance of the PCB request signal has
elapsed.(NP2,QP3)
Remedy: The board stalled on the conveyor. Remove the board from the conveyor or re-load the board.
------------------------------
Code: 15024004
Display: (Differs according to the machine.)
Used by:
Cause: The lifter did not reach its target position within the preset time limit.
Remedy: The lifter is not working. At the I/O map check the lifter operation and the sensor input.
------------------------------
Code: 15024005
Display: (Differs according to the machine.)
Used by:
Cause: The sequencer did not reply within the preset time.
Remedy: There is no reply from the loader's sequencer. Switch off the machine and then re-boot it. If the
problem recurs it is probably due to a wiring fault or damage to the sequencer.
------------------------------
Code: 15024006
Display: (Differs according to the machine.)
Used by:
Cause: The reference pin did not reach its target position within the preset time limit.
Remedy: The reference pin is not moving. At the I/O map check the reference pin and the sensor input.
------------------------------
Code: 15024007
Display: (Differs according to the machine.)
Used by: IP3
Cause: Vertical movement of the 2 level conveyor could not be completed within the preset time limit.
Remedy: The 2 level conveyor could not move up or down within the set time. Check that it is possible for
the 2 level conveyor to freely move up and down.
------------------------------
Code: 15024008
Display: Cycle alarm (cylinder) conveyor adj. clutch
Used by: GSP5,GP551,GP6
Cause: The clutch could not enter the conveyor connecting notch within the preset time limit.
Remedy: Check for items that may be interfering with clutch movement. Check the widths of the main
and out conveyors to make sure they match. Check the sensors at the I/O board.
------------------------------
Code: 15024009
Display: Cycle alarm (cylinder) backup pin
Used by: GSP5,GP551,GP6
Cause: The backup pin could not lock or unlock within the preset time limit.
Remedy: Check the sensors at the I/O board.
------------------------------
Code: 1502400A
第 1104 页
Display: Package unclamping error!
Used by: QP301
Cause: The ON or OFF signal for the package unclamper timed out.
Remedy: Check for interference with the package unclamper.
------------------------------
Code: 15026007
Display: Package unclamper sensor error!
Used by: QP301
Cause: Both the ON and OFF sensor of the package unclamper are on.
Remedy: Check both sensors.
------------------------------
Code: 15031001
Display:
Used by: CP5,GL5,GL541,IP3
Cause: Operation was cancelled because of an alarm from the application.
Remedy: None.
------------------------------
Code: 15031002
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: Loading position alarm.
Remedy: None.
------------------------------
Code: 15031003
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: Lifter position error
Remedy: None.
------------------------------
Code: 15031004
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,CP-752,GL5,GL541,IP3
Cause: Interlock error
Remedy: None.
------------------------------
Code: 15031005
Display: Loader ROM Error
Used by:
Cause: The board loader PLC ROM version is newer than the machine ROM version (i.e. the number of
the machine version is lower than the number of the PLC version).
Remedy: Contact Fuji.
------------------------------
Code: 15031006
Display: Brd supply number rpt error
Used by: CP643
Cause: Board quantity cannot be ascertained when loading a board from in-carrier to main conveyor.
Remedy: Turn the machine off,then on again.
------------------------------
Code: 15031007
Display: IN-loader brd rpt error
Used by: CP643
第 1105 页
Cause: The quantity of boards in the in-loader (the in-lifter and the in-carrier) cannot be ascertained
during flushout operation.
Remedy: Turn the machine off,then on again.
------------------------------
Code: 15031008
Display: IN搬运轨道的升降台上升失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: IN搬运轨道的升降台上升失败。
Remedy: IN搬运轨道的升降台未上升时,请确认通过升降台的配管是否脱离。
上升时,请确认IN升降台上升确认传感器是否正常地动作。
------------------------------
Code: 15031009
Display: IN搬运轨道的升降台下降失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: IN搬运轨道的升降台下降失败。
Remedy: 请确认IN升降台上升确认传感器是否正常地动作。请确认通过升降台的配管是否脱离。
------------------------------
Code: 1503100A
Display: MAIN搬运轨道的升降台上升失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的升降台上升失败。
Remedy: MAIN搬运轨道的升降台未上升时,请确认通过升降台的配管是否脱离。
上升时,请确认MAIN升降台上升以及下降确认传感器是否正常地动作。
------------------------------
Code: 1503100B
Display: MAIN搬运轨道的升降台下降失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的升降台下降失败。
Remedy: MAIN搬运轨道的升降台未下降时,请确认通过升降台的配管是否脱离。
请确认MAIN升降台上升以及下降确认传感器是否正常地动作。
------------------------------
Code: 1503100C
Display: MAIN搬运轨道的阻挡块上升失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的阻挡块上升失败。
Remedy: MAIN搬运轨道的阻挡块未上升时,请确认通过升降台的配管是否脱离。
请确认阻挡块上升确认传感器是否正常地动作。
------------------------------
Code: 1503100D
Display: MAIN搬运轨道的阻挡块下降失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的阻挡块下降失败。
Remedy: 请确认阻挡块上升确认传感器是否正常地动作。请确认通过阻挡块的配管是否脱离。
------------------------------
Code: 1503100E
Display: 向MAIN搬运轨道的电路板到达传感器的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 向MAIN搬运轨道的电路板到达传感器的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认MAIN到达传感器是否正常地动作
------------------------------
第 1106 页