FUJI错误代码查询 - 第1115页
------------------------------ Code: 15040215 Display: In-conveyor panel conveyance error. Used by: CP-732E, CP-742ME, CP-742E Cause: The in-conveyor's second panel arrival confirmation sensor (X0AE) failed to detec…
Remedy: Check that the board has been stopped by the in-conveyor stopper. Check the X033:
IN_PASS_CHK (in-conveyor board pass check) signal at the I/O map.
------------------------------
Code: 15040210
Display: In-carrier advance limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier has deviated from the advance limit position.
Remedy: Check the in-carrier position. If the in-carrier is at the prescribed advance limit position, check
the in-carrier's advance limit sensor. If the in-carrier is not at the prescribed advance limit position, move
the in-carrier to its advance limit position.
------------------------------
Code: 15040211
Display: In-conveyor panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Following a panel request during a SMEMA specification operation, the panel failed to reach the
in-conveyor panel loading confirmation sensor (X0B0) position within the prescribed time period.
Remedy: Check to see if the panel is stopped on the in-conveyor. If the panel is stuck, readjust the
conveyor width to accommodate the panel .
------------------------------
Code: 15040212
Display: In-conveyor panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-conveyor's first panel deceleration sensor (X0AB) failed to detect the panel within the
prescribed period of time even though the panel has passed the in-conveyor's panel loading confirmation
sensor (X0B0) position. Alternatively, the in-conveyor's first panel sensor (X0AC) switched on before the
in-conveyor's first panel deceleration sensor switched on.
Remedy: Check the panel conveyance condition, and verify that the in-conveyor's first panel deceleration
sensor is operating correctly. Also check to see if the in-conveyor's first panel sensor is detecting
something other than the panel.
------------------------------
Code: 15040213
Display: In-conveyor panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-conveyor's first panel deceleration sensor (X0AB) failed to detect the panel within the
prescribed period of time even though the panel has passed the in-conveyor's panel loading confirmation
sensor (X0B0) position. Alternatively, the in-conveyor's first panel sensor (X0AC) switched on before the
in-conveyor's first panel deceleration sensor switched on.
Remedy: Check the panel conveyance condition, and verify that the in-conveyor's first panel deceleration
sensor and first panel sensor are operating correctly. Also check to see if the in-conveyor's first panel
sensor is detecting something other than the panel .
------------------------------
Code: 15040214
Display: In-conveyor panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-conveyor's second panel deceleration sensor (X0AD) failed to detect the panel within the
prescribed period of time even though the panel has passed the in-conveyor's panel loading confirmation
sensor (X0B0) position. Alternatively, the in-conveyor's second panel sensor (X0AE) switched on before
the in-conveyor's second panel deceleration sensor switched on.
Remedy: Check the panel conveyance condition, and verify that the in-conveyor's second panel
deceleration sensor and second panel sensor are operating correctly. Also check to see if the in-conveyor's
second panel sensor is detecting something other than the panel .
第 1114 页
------------------------------
Code: 15040215
Display: In-conveyor panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-conveyor's second panel arrival confirmation sensor (X0AE) failed to detect the panel
within the prescribed period of time even though the panel has passed the in-conveyor's second panel
deceleration sensor (X0AD) position.
Remedy: Check the panel conveyance condition, and verify that the in-conveyor's second panel
deceleration sensor is operating correctly.
------------------------------
Code: 15040216
Display: In-conveyor panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The interval between the first and second panel s is incorrect. Alternatively, the interval
confirmation sensor (X0AF) is mounted in the wrong position.
Remedy: Check the first and second panel interval setting in the production program. Adjust the
mounting position of the interval confirmation sensor (X0AF) if necessary. If this error occurs when both
the interval setting data and the sensor mounting position are correct, check to see if the interval
confirmation sensor is operating correctly. This sensor should be on when no panel is detected.
------------------------------
Code: 15040217
Display: In-lifter sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-lifter's up limit and down limit sensors are both off.
Remedy: Move the in-lifter to either the up limit or the down limit position. If this error occurs even when
the in-lifter is at the up or down limit position, adjust the sensor mounting positions. If the sensors still
fail to switch on, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040218
Display: In-lifter sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-lifter's up limit and down limit sensors are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040219
Display: In-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carriers advance limit and retract limit sensors are both off.
Remedy: Move the in-carrier to either the advance limit or the retract limit position. If this error still
occurs, adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their
mounting positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504021A
Display: In-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carriers advance limit and retract limit sensors are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504021B
第 1115 页
Display: In-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the in-carrier's advance limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504021C
Display: In-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the in-carrier's advance limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504021D
Display: In-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the in-carrier's retract limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504021E
Display: In-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the in-carrier's retract limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504021F
Display: In-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier cannot be advanced, as there is a risk of interference with the panel on the in-lifter
(because it is not known if there is a panel on the in-carrier).
Remedy: Remove the panel from the in-lifter.
------------------------------
Code: 15040220
Display: In-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier cannot be retracted because there is a risk of interference between the panel on the in-
carrier and the panel on the in-lifter.
Remedy: Remove the panel from the in-lifter.
------------------------------
Code: 15040221
Display: In-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: There is a risk of interference with the panel on the in-lifter when the in-carrier is retracted
because it is not known if there is a panel on the in-carrier.
Remedy: Remove the panel from the in-lifter.
------------------------------
Code: 15040222
第 1116 页