FUJI错误代码查询 - 第1129页

Cause: Only the second panel is present. Remedy: Check to see if the first panel is being conveyed properly. ------------------------------ Code: 15040335 Display: Main conveyor unclamp limit sensor input error. Used by:…

100%1 / 5282
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table up/down travel was not completed within the prescribed period of time.
Remedy: Check for objects which may be interfering with XY-table up/down travel.
------------------------------
Code: 15040330
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A clamp limit sensor failed to switch on at one of the following:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is clamped properly. If clamped properly but this error occurs anyway,
adjust the mounting position of the clamp limit sensor. If the error still occurs, there may be a sensor
wiring problem or a sensor failure.
------------------------------
Code: 15040331
Display: XY-table unclamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An unclamp limit sensor was not triggered at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is clamped properly. If clamped properly but this error occurs anyway,
adjust the mounting position of the unclamp limit sensor. If the error still occurs, there may be a sensor
wiring problem or a sensor failure.
------------------------------
Code: 15040332
Display: XY-table unclamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An unclamp limit sensor failed to switch on at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is properly unclamped. If properly unclamped but this error occurs
anyway, adjust the mounting position of the unclamp limit sensor. If the error still occurs, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040333
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A clamp limit sensor failed to switch off at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is properly unclamped. If properly unclamped but this error occurs
anyway, adjust the mounting position of the clamp limit sensor. If the error still occurs, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040334
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
第 1128 页
Cause: Only the second panel is present.
Remedy: Check to see if the first panel is being conveyed properly.
------------------------------
Code: 15040335
Display: Main conveyor unclamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor unclamp limit sensor input error.
Remedy: Check to see if the sensors (X061, X062, X064) are operating properly.
------------------------------
Code: 15040336
Display: Main conveyor clamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor clamp limit sensor input error.
Remedy: Check to see if the sensors (X05F, X060, X063) are operating properly.
------------------------------
Code: 15040337
Display: Main conveyor clamp limit and unclamp limit sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor clamp limit and unclamp limit sensor logic error.
Remedy: Verify that all sensors (X05F to X064) are operating properly.
------------------------------
Code: 15040338
Display: Loading position sensor error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Logic check error at loading position sensors. The sensors at both the IN and OUT sides are on.
Remedy: Verify that the sensors (X0BF to X0DA) are operating properly.
------------------------------
Code: 15040339
Display: Main lifter sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The main lifter UP sensor and the main lifter OT sensor are both on.
Remedy: Verify that the sensors (X05C to X05E) are operating properly.
------------------------------
Code: 1504033A
Display: Table height sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A logic error occurred at the table height sensor when placing parts. The DOWN limit sensor
switched off.
Remedy: Verify that the table height sensor is operating properly.
------------------------------
Code: 1504033B
Display: XY-table travel time-up.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table travel was not completed within the prescribed period of time.
Remedy: Check for objects which may be interfering with XY-table travel.
------------------------------
Code: 1504033C
Display: Loader unit error
Used by: NP2,QP3
Cause: Error occurred between the machine and the motor control panel.
Remedy: Restart the machine.
第 1129 页
------------------------------
Code: 1504033E
Display: Middle loading sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table loading height sensor (X05C) is not operating properly. This sensor fails to switch
on when the Z-axis is at the middle loading position. Alternatively, this sensor switches on when the Z-
axis is not at the middle loading position +/-500 pulses.
Remedy: Adjust the mounting position of the XY-table loading height sensor (X05C).
------------------------------
Code: 1504033F
Display: Panel check error
Used by: CP-732E, CP-742ME, CP-742E
Cause: The sensor check results differ from the machine's current status memory.
Remedy: Adjust the position of the sensor as required so that the panel on the main conveyor is correctly
detected.
------------------------------
Code: 15040340
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: A panel was loaded onto the main-conveyor, however, the panel was not detected (ON) at either
the XY-table panel speed
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properly a
nd confirm the panel status.
------------------------------
Code: 15040341
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: The panel passed through the XY-table panel speed reduction sensor, however, it was not
detected at the panel arrival c
heck sensor (X0AF) within the specified time limit.
Remedy: Check that the panel arrival check sensor is functioning properly and confirm the panel status.
------------------------------
Code: 15040342
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: An attempt was made to unload the board from the main-conveyor however, the XY-table panel
speed reduction sensor (X0AE
) or the panel arrival check sensor (X0AF) did not deactivate (OFF) within the specified time limit.
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properl
------------------------------
Code: 15040343
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: An attempt was made to transfer a panel from the main-conveyor, however, the out-conveyor
unload panel sensor (X0CB) di
d not activate (ON) within the specified time.
Remedy: Check that the out-conveyor panel arrival sensor is functioning properly and confirm the panel
status.
------------------------------
第 1130 页