Cause: The ascend and descend operation of the manipulator on the unloading side was not completed within the set amount of time. Remedy: Check the ascend/descend operation of the manipulator on the unloading side and th…

100%1 / 5282
Used by: QP132
Cause: The pallet unload cylinder extend sensor (X061: P.OUT FWEND) did not come on in the given
time (QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040862
Display: UNLD PLT CLAMP TUP
Loader error: 15040862
Used by: QP132
Cause: The unloaded pallet unclamp check sensor (X072: P OUT PLT UCLP) did not turn off in the given
time (QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040863
Display: UNLD PLT UNCLAMP TUP
Loader error: 15040863
Used by: QP132
Cause: The OUT pallet unclamp limit check sensor (X05C:P OUT PLT UCLP) did not turn on within the
specified time.
Remedy: Use I/O commands to make sure that the sensor is functioning normally, and adjust it if
necessary.
------------------------------
Code: 15040866
Display: UNLD MANI HOOK OPEN TUP
Loader error: 15040866
Used by: QP132
Cause: The out-conveyor manipulator claw has not opened in the given time.
Remedy: Check the PCB unload claw (X07B: PCB UL HOOK OP) operation using I/O commands and
adjust if necessary.
------------------------------
Code: 15040867
Display: UNLD MANI HOOK CLOSE TUP
Loader error: 15040867
Used by: QP132
Cause: The open and close operation of the manipulator hook on the unloading side was not completed
within the set amount of time.
Remedy: Check the open and close operation of the unloading side manipulator hook and the operation of
the open/close check sensors.
------------------------------
Code: 15040868
Display: UNLD MANI RISE TUP
Loader error: 15040868
Used by: QP132
Cause: The out-conveyor manipulator claw has not been raised in the given time.
Remedy: Check the PCB unload claw (X07A: PCB UL UPCHK) operation using I/O commands and adjust
if necessary.
------------------------------
Code: 15040869
Display: UNLD MANI DOWN TUP
Loader error: 15040869
Used by: QP132
第 1155 页
Cause: The ascend and descend operation of the manipulator on the unloading side was not completed
within the set amount of time.
Remedy: Check the ascend/descend operation of the manipulator on the unloading side and the
operation of the exit board transport upper-limit and lower-limit sensors.
------------------------------
Code: 1504086C
Display: UNLD MANI PCB PICKUP ERROR
Loader error: 1504086C
Used by: QP132
Cause: The unloading side manipulator failed to grab the board from the pallet during the pick operation.
Remedy: Make sure the board unclamp operation is working correctly. Check the operating status of the
exit transport board-check sensor. Make sure that the position at which the board is grabbed from the
pallet is correct.
------------------------------
Code: 1504086D
Display: UNLD MANI PCB PLACE ERROR
Loader error: 1504086D
Used by: QP132
Cause: The unloading side manipulator failed to place the board on the out-conveyor.
Remedy: Check the operating status of the exit transport board-check sensor and the out-conveyor
board-arrival-check sensor.
------------------------------
Code: 1504086F
Display: UNLD MANI PCB LOSE ERROR
Loader error: 1504086F
Used by: QP132
Cause: The board was lost during movement of the unloading side manipulator.
Remedy: Make sure that the board did not slip off during the manipulator movement. Check the
operating status of the exit transport board-check sensor.
------------------------------
Code: 15040872
Display: UNLD MANI TURN TUP
Loader error: 15040872
Used by: QP132
Cause: The rotation operation of the unloading side manipulator was not completed within the set
amount of time.
Remedy: Check the rotation operation of the unloading side manipulator and the operation of the exit
board transport rotation sensor.
------------------------------
Code: 15040873
Display: UNLD MANI BACK TUP
Loader error: 15040873
Used by: QP132
Cause: The return rotation operation of the unloading side manipulator was not completed within the set
amount of time.
Remedy: Check the return operation of the unloading side manipulator and the operation of the exit
board transport return sensor.
------------------------------
Code: 15040875
Display: Abolished.
Used by: QP122
第 1156 页
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040877
Display: UNLD MANI RISE FAIL
Loader error: 15040877
Used by: QP132
Cause: The exit board transport upper-limit sensor went off during movement of the unloading side
manipulator.
Remedy: Make sure that the air pressure used to raise the board which is to be transported out, has not
fallen. Check the operation of the exit board transport upper-limit sensor.
------------------------------
Code: 15040880
Display: UNLD 10-SHIFT FORWARD TUP
Loader error: 15040880
Used by: QP132
Cause: The out-conveyor pallet pusher (which shifts the pallet a further 10 mm) did not reach its
extended position in the given time.
Remedy: Check the pallet pusher is at its extended position (X073: P.OUT PLT RSFT) using I/O
commands and adjust if necessary.
------------------------------
Code: 15040881
Display: UNLD 10-SHIFT BACKWARD TUP
Loader error: 15040881
Used by: QP132
Cause: The out-conveyor pallet pusher (which shifts the pallet a further 10 mm) did not reach its retract
position in the given time.
Remedy: Check the pallet pusher is at its retract position (X074: P.OUT PLT LSFT)using I/O commands
and adjust if necessary.
------------------------------
Code: 15040882
Display: UNLD TRANS FORWARD TUP
Loader error: 15040882
Used by: QP132
Cause: The pallet pusher that moves a pallet from the pallet unloader to the return-conveyor did not
finish extending in the given time.
Remedy: Check the X075: P.OUT PUSH FED operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040883
Display: UNLD TRANS BACKWARD TUP
Loader error: 15040883
Used by: QP132
Cause: The pallet pusher that moves a pallet from the pallet unloader to the return-conveyor did not
finish retracting in the given time.
Remedy: Check the X076: P.OUT PUSH BED operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040884
Display: UNLD-RCV CHANGE TUP
Loader error: 15040884
Used by: QP132
Cause: After being unloaded to the return-conveyor, the pallet did not activate the return-conveyor pass-