FUJI错误代码查询 - 第1190页

Code: 1CA??004 Display: 1CA??004 Used by: Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B, 0C, 0D, 15, or 18 this signifies that the search fo…

100%1 / 5282
Cause: The part size is larger than the backlight size.
Remedy: Check the part and backlight sizes.
------------------------------
Code: 1CA00F04
Display: 1CA00F04
Used by:
Cause: A Vision_type setting was specified that does not exist in part data.
Remedy: Verify what types of vision types in part data can be utilized with the vision processing software
that is currently being used. In the case that part data is correct then there was a failure with the
initialization of the vision processing system during startup. If this error occurs contact Fuji.
------------------------------
Code: 1CA??001
Display: 1CA??001
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that the part is larger than the diameter of the specified
background disk. If "??" equals 64, 78, 79, 7B, 7C, 96, 97, 98, 99or A0 then the part data description is
incorrect.
If "??" equal FC then the part is smaller than the specified nozzle size.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, 17, 18, or 28 then the production program should be
corrected so that a nozzle is employed that uses a background disk which is larger than the one currently
being used. If "??" equals 64, 78, 79, 7B, 7C, 96, 97, 98, 99or A0 this error will occur when the part is
being registered in the vision processing system. Vision processing can in fact be executed in this case,
however, the results cannot be guaranteed. Inspect the part data. If "??" equal FC then the part could not
be found because it is smaller than the specified nozzle size. Check for errors in the nozzle data.
------------------------------
Code: 1CA??002
Display: 1CA??002
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that the part is smaller than the specified nozzle diameter.
If "??" equals 1E, 64, 78, 79, 7B, 7C, 96, 97, 98, 99, A0, AC, B4, F0, F1 or F2 then the part data
description is incorrect. If "??" equal FC then contour tracing cannot begin due to a bent nozzle.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, 17, 18, or 28 then the part is smaller than the specified
nozzle diameter and the part in question cannot be recognized. Make sure the nozzle data is correct. If
"??" equals 1E, 64, 78, 79, 7B, 7C, 96, 97, 98, 99, A0, AC, B4, F0, F1 or F2 this error will occur when the
part is being registered in the vision processing system. Vision processing cannot be executed. Inspect
the part data. If "??" equal FC then the nozzle's rotational center is not aligned with the nozzle image.
Check for a bent nozzle.
------------------------------
Code: 1CA??003
Display: 1CA??003
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that there is an error in the part data. If "??" equal FC then
the part's X-direction size exceeds the tolerance value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, or 17 the description in Bodysize in part data is
incorrect. Make the necessary corrections to this data item in part data. If "??" equals 18 or 28 the
description of the part in part data is incorrect. Make the necessary corrections in part data. If "??" equal
FC then the part size is incorrect. Correct the part data.
------------------------------
第 1189 页
Code: 1CA??004
Display: 1CA??004
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that the search for the part boundaries could not begin because the nozzle
is bent. If "??" equals 14 or 28 then there is an error in the descriptions of the leads in part data. If "??"
equals 16 or 17 this indicates that the lead descriptions in part datahave been set to "0". If "??" equal FC
then the part's Y-direction size exceeds the tolerance value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 15, or 18 then the nozzle center of rotation and the image of the
nozzle do not conform. Make sure the nozzle is not bent. If "??" equals 14, 16, 17, or 28 then make the
necessary corrections to the lead descriptions in part data. If "??" equal FC then the part size is incorrect.
Correct the part data.
------------------------------
Code: 1CA??005
Display: 1CA??005
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that the part outline could not be found. If "??" equals 14 or 28 this
indicates that the lead pitch setting is either too narrow or too wide. If "??" equals 16 or 17 then the lead
width is smaller than the lead pitch. If "??" equal 7B, 7C, 96, 97, 98, 99, F0 or FE then invalid "P_Pattern"
value.
Remedy: If "??" equals 0A, 0B, 0C, or 0D then make sure that there are no unexpected protrusions
resulting from a burr or something being stuck to the part. If "??" equals 14, 16, 17, or 28 then make the
necessary corrections in part data. If "??" equals 15 or 18 then make sure that there are no unexpected
protrusions resulting from a burr or something being stuck to the part. If there is a protrusion on any
side other than the side opposite the lead segment on one portion of the part, then this Visio _type cannot
be used. Try using vision processing number 20 or 100 in such a case. If "??" equal 7B, 7C, 96, 97, 98,
99, F0 or FE then "P_Pattern" must be 1 to 16, 23, 24, 33 or 34.Check the "P_Pattern" setting.
------------------------------
Code: 1CA??006
Display: 1CA??006
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that part positioning was not possible because there were too many
segments in the outline of the part. If "??" equals 14 or 28 then there are bent leads. If "??" equals 16 or
17 this indicates that the part could not be found because the nozzle was bent. If "??" equal 64, 78, 79,
7A, 7B, 7C, 96, 97, 98, 99, A0, F0 or FE then invalid "Result" value.
Remedy: If "??" equals 0A, 0B, 0C, or 0D then the part has too many slight protrusions such as burrs
causing breaks in the linear segments. If "??" equals 14 or 28 this indicates that the bend in the leads has
exceeded the permissible range specified in the pitch limit in part data. If "??" equals 15 or 18 then the
part has too many slight protrusions such as burrs causing breaks in the linear segments. Try
Vision_type 20 or 100 in such a case. If "??" equals 16 or 17 then either re-measure the nozzl center or
replace with another nozzle. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99, A0, F0 or FE then this
algorithm is not compatible with matrix tables.Check whether 128 is input at "Result".
------------------------------
Code: 1CA??007
Display: 1CA??007
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 then the part pickup status is bad. If "??" equals 14 or 28 this indicates that not a
single lead was detected. If "??" equals 16 or 17, the inspected leads were smaller than specified. If "??"
第 1190 页
equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then not enough leads were detected.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 15, or 18 this indicates that the necessary number of corners
(more than two) were not found for determining the part position. Make sure that the nozzle is not bent
and that the part is being properly picked from the feeder. If "??" equals 14 or 28 then make sure that the
part data is correct. In particular make sure that the P_pattern setting is correct. If "??" equals 16 or 17
then check the part data. If the part data is satisfactory then decrease the Body_ and Body_y settings in
Tolerance information. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then a minimum of two
leads must be detected.Check the number of leads set, and "Result".
------------------------------
Code: 1CA??008
Display: 1CA??008
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 10, 15, or 18 this signifies that the X-dimension of the part has exceeded the permissible range. If
"??" equals 14 or 28 then a lead was found in a location where no lead was expected. If "??" equals 16 or
17 then the inspected leads were larger than specified. If "??" equal 7B, 7C, 96, 97, 98, 99, F0 or FE then
invalid lead width value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 10, 15, or 18 then the part size is wrong. Make sure that the part
data is correct. If "??" equals 14 or 28 then verify that the lead arrangement information is correct. Also,
be sure that the correct part is being used. If "??" equals 16 or 17 then check the part data. If the part
data is satisfactory then increase the Body_x and Body_y settings in Tolerance information. If "??" equal
7B, 7C, 96, 97, 98, 99, F0 or FE then the lead width input is 0 or less. Check the lead width.
------------------------------
Code: 1CA??009
Display: 1CA??009
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 10, 15, or 18 this signifies that the Y-dimension of the part has exceeded the permissible range.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 10, 15, or 18 then the part size is wrong. Make sure that the part
data is correct.
------------------------------
Code: 1CA??00A
Display: 1CA??00A
Used by:
Cause: If "??" equals 0D or 18 then the supply orientation of the part is incorrect. If "??" equal 64, 78, 79,
7A, 7B, 7C, 96, 97, 98, 99 or F0 then invalid lead length value.
Remedy: If "??" equals 0D the error has occurred as a result of the direction test that is utilized when
tantalum sprague components are processed. If "??" equals 18 the error has occurred as a result of the
direction test that is utilized when trimmer resistor components are processed. Set the correct supply
orientation. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then the lead length input is 0 or
less. Check the lead length.
------------------------------
Code: 1CA??00B
Display: 1CA??00B
Used by:
Cause: If "??" equals 0A, 14 or 28 this signifies that positioning could not be determined correctly
because the image was oscillating. If "??" equal A0 then the part angle is being obtained incorrectly. If "??"
equal 64, 78, 79, 7A, 7B, or 7C then the element size is larger than the body size.
Remedy: If "??" equals 0A, 14 or 28 then this error occurs on the FCP5. Carry out readjustment of the
index servo. If "??" equal A0 then check to see if burrs on the part edges, or dust on the background is
causing an image problem. If "??" equal 64, 78, 79, 7A, 7B, or 7C then check the element size and the
第 1191 页