equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then not enough leads were detected. Remedy: If "??" equals 0A, 0B, 0C, 0D, 15, or 18 this indicates that the necessary number of corners (more than two) were …
Code: 1CA??004
Display: 1CA??004
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that the search for the part boundaries could not begin because the nozzle
is bent. If "??" equals 14 or 28 then there is an error in the descriptions of the leads in part data. If "??"
equals 16 or 17 this indicates that the lead descriptions in part datahave been set to "0". If "??" equal FC
then the part's Y-direction size exceeds the tolerance value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 15, or 18 then the nozzle center of rotation and the image of the
nozzle do not conform. Make sure the nozzle is not bent. If "??" equals 14, 16, 17, or 28 then make the
necessary corrections to the lead descriptions in part data. If "??" equal FC then the part size is incorrect.
Correct the part data.
------------------------------
Code: 1CA??005
Display: 1CA??005
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that the part outline could not be found. If "??" equals 14 or 28 this
indicates that the lead pitch setting is either too narrow or too wide. If "??" equals 16 or 17 then the lead
width is smaller than the lead pitch. If "??" equal 7B, 7C, 96, 97, 98, 99, F0 or FE then invalid "P_Pattern"
value.
Remedy: If "??" equals 0A, 0B, 0C, or 0D then make sure that there are no unexpected protrusions
resulting from a burr or something being stuck to the part. If "??" equals 14, 16, 17, or 28 then make the
necessary corrections in part data. If "??" equals 15 or 18 then make sure that there are no unexpected
protrusions resulting from a burr or something being stuck to the part. If there is a protrusion on any
side other than the side opposite the lead segment on one portion of the part, then this Visio _type cannot
be used. Try using vision processing number 20 or 100 in such a case. If "??" equal 7B, 7C, 96, 97, 98,
99, F0 or FE then "P_Pattern" must be 1 to 16, 23, 24, 33 or 34.Check the "P_Pattern" setting.
------------------------------
Code: 1CA??006
Display: 1CA??006
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 this signifies that part positioning was not possible because there were too many
segments in the outline of the part. If "??" equals 14 or 28 then there are bent leads. If "??" equals 16 or
17 this indicates that the part could not be found because the nozzle was bent. If "??" equal 64, 78, 79,
7A, 7B, 7C, 96, 97, 98, 99, A0, F0 or FE then invalid "Result" value.
Remedy: If "??" equals 0A, 0B, 0C, or 0D then the part has too many slight protrusions such as burrs
causing breaks in the linear segments. If "??" equals 14 or 28 this indicates that the bend in the leads has
exceeded the permissible range specified in the pitch limit in part data. If "??" equals 15 or 18 then the
part has too many slight protrusions such as burrs causing breaks in the linear segments. Try
Vision_type 20 or 100 in such a case. If "??" equals 16 or 17 then either re-measure the nozzl center or
replace with another nozzle. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99, A0, F0 or FE then this
algorithm is not compatible with matrix tables.Check whether 128 is input at "Result".
------------------------------
Code: 1CA??007
Display: 1CA??007
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 15, or 18 then the part pickup status is bad. If "??" equals 14 or 28 this indicates that not a
single lead was detected. If "??" equals 16 or 17, the inspected leads were smaller than specified. If "??"
第 1190 页
equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then not enough leads were detected.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 15, or 18 this indicates that the necessary number of corners
(more than two) were not found for determining the part position. Make sure that the nozzle is not bent
and that the part is being properly picked from the feeder. If "??" equals 14 or 28 then make sure that the
part data is correct. In particular make sure that the P_pattern setting is correct. If "??" equals 16 or 17
then check the part data. If the part data is satisfactory then decrease the Body_ and Body_y settings in
Tolerance information. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then a minimum of two
leads must be detected.Check the number of leads set, and "Result".
------------------------------
Code: 1CA??008
Display: 1CA??008
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 10, 15, or 18 this signifies that the X-dimension of the part has exceeded the permissible range. If
"??" equals 14 or 28 then a lead was found in a location where no lead was expected. If "??" equals 16 or
17 then the inspected leads were larger than specified. If "??" equal 7B, 7C, 96, 97, 98, 99, F0 or FE then
invalid lead width value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 10, 15, or 18 then the part size is wrong. Make sure that the part
data is correct. If "??" equals 14 or 28 then verify that the lead arrangement information is correct. Also,
be sure that the correct part is being used. If "??" equals 16 or 17 then check the part data. If the part
data is satisfactory then increase the Body_x and Body_y settings in Tolerance information. If "??" equal
7B, 7C, 96, 97, 98, 99, F0 or FE then the lead width input is 0 or less. Check the lead width.
------------------------------
Code: 1CA??009
Display: 1CA??009
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 10, 15, or 18 this signifies that the Y-dimension of the part has exceeded the permissible range.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 10, 15, or 18 then the part size is wrong. Make sure that the part
data is correct.
------------------------------
Code: 1CA??00A
Display: 1CA??00A
Used by:
Cause: If "??" equals 0D or 18 then the supply orientation of the part is incorrect. If "??" equal 64, 78, 79,
7A, 7B, 7C, 96, 97, 98, 99 or F0 then invalid lead length value.
Remedy: If "??" equals 0D the error has occurred as a result of the direction test that is utilized when
tantalum sprague components are processed. If "??" equals 18 the error has occurred as a result of the
direction test that is utilized when trimmer resistor components are processed. Set the correct supply
orientation. If "??" equal 64, 78, 79, 7A, 7B, 7C, 96, 97, 98, 99 or F0 then the lead length input is 0 or
less. Check the lead length.
------------------------------
Code: 1CA??00B
Display: 1CA??00B
Used by:
Cause: If "??" equals 0A, 14 or 28 this signifies that positioning could not be determined correctly
because the image was oscillating. If "??" equal A0 then the part angle is being obtained incorrectly. If "??"
equal 64, 78, 79, 7A, 7B, or 7C then the element size is larger than the body size.
Remedy: If "??" equals 0A, 14 or 28 then this error occurs on the FCP5. Carry out readjustment of the
index servo. If "??" equal A0 then check to see if burrs on the part edges, or dust on the background is
causing an image problem. If "??" equal 64, 78, 79, 7A, 7B, or 7C then check the element size and the
第 1191 页
body sized.
------------------------------
Code: 1CA??00C
Display: 1CA??00C
Used by:
Cause: If "??" equals 28 this signifies that the body has failed to be detected. If "??" equal A0 then the
body edge cannot be detected. If "??" equal 64, 78, 79, 7A, 7B, 7C or F0 then invalid lead pitch value.
Remedy: If "??" equals 28 then check the dimensions of the part. If "??" equal A0 then check for errors in
the part data's "part size" setting, and in the element_data detection position. If "??" equal 64, 78, 79, 7A,
7B, 7C or F0 then the lead pitch is smaller than the lead width.Check the lead pitch and the lead width.
------------------------------
Code: 1CA??00D
Display: 1CA??00D
Used by:
Cause: If "??" equals 28 this signifies that there were no body detection points. If "??" equal A0 then
mismatch between the part size and the part data. If "??" equal 64, 78, 79, 7A, 7B, 7C or F0 then there are
overlapping elements.
Remedy: If "??" equals 28 then the results of calculating the body detection points using the body data
prevented the body from being detected because the leads were concealed by the body. If "??" equal A0
then specify the correct part size in part data. When there is a large size difference from part to part,
specify a large tolerance value. If "??" equal 64, 78, 79, 7A, 7B, 7C or F0 then check the element data, and
ensure none of the elements are overlapping.
------------------------------
Code: 1CA??010
Display: 1CA??010
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 64, 78,
79, 96, 99, 9B or 9E this signifies that the positioning phase could not be determined. If "??" equal A0
then coarse positioning is not possible. If "??" equal F0, F1 or F2 then search failed.
Remedy: If "??" equals 64, 78, or 79 this indicates that there is a problem with the brightness of the
image. Make sure that there is no dirt or dust reflected in the background. If "??" equals 96,99, 9B or 9E
then verify that the part and mechanical chuck do not lie outside of the camera field of vision. Also make
sure that there is not a problem with the brightness of the image and that there are no contaminants
reflected in the background.
If "??" equal A0 then cCheck for the following:
o Part or mechanical chuck protruding from the camera's field of vision.
o Image brightness problem.
o Image problem caused by dust, etc., on the part background.
When a nozzle is being used, the size of the nozzle's reflective disk should be at least 1.7 times the part
size.
If "??" equal F0, F1 or F2 then check for errors in the part data. Create a model to reduce the size of the
circumscribed square outline for the entire model.
------------------------------
Code: 1CA??011
Display: 1CA??011
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 1E, 64,
78, 79, AC, or FE then boundary detection could not begin because the nozzle was bent. The image lies
outside the scan area. If "??" equals 7C, 82, 83, 98, 9D or B4 this indicates that the leads could not be
acquired from the body and background. If "??" equals 8C, E6, E7 or E9 there are too few leads described
in part data. If "??" equal F0, F1 or F2 then model size exceeds the tolerance range.