Display: 1CAF3005 Used by: Cause: The defined lead elements do not match with the detected elements. Remedy: Check the following items in element data. 帴Lead position 帴Lead center tolerance 帴Lead width 帴Lead width tolera…

100%1 / 5282
Remedy: Examine the condition of the nozzle and replace if bent. Perform nozzle center measurement
once more if the nozzle is not bent.
------------------------------
Code: 1CA10006
Display: 1CA10006
Used by: Vision system
Cause: The maximum width for the shortest side of the part is smaller than the permissible part size.
Remedy: Check the pick-up condition of the acquired part image.
------------------------------
Code: 1CA10007
Display: 1CA10007
Used by: Vision system
Cause: The maximum width for the shortest side of the part is larger than the [Part size + nozzle
diameter].
Remedy: The part supply direction is incorrect, or more than half of the nozzle is protruding from the
part.
------------------------------
Code: 1CA1000C
Display: 1CA1000C
Used by: Vision system
Cause: The longest side of the part is 1.05 times smaller than the nozzle diameter.
Remedy: Check the pick-up condition at the acquired part image.
------------------------------
Code: 1CA10010
Display: 1CA10010
Used by: Vision system
Cause: The part supply direction is incorrect. (Cut-check error)
Remedy: Check the part supply direction.
------------------------------
Code: 1CAF3001
Display: 1CAF3001
Used by:
Cause: The lead element data is incorrect. It is not possible to enter consecutive elements with a result
of "128".
Remedy: When result "128" is being used, specify the result for the previous element as a value other
than "128".
------------------------------
Code: 1CAF3002
Display: 1CAF3002
Used by:
Cause: No elements can be found.
Remedy: Ensure that element data exists in part data, and that the result is specified as a value other
than "0".
------------------------------
Code: 1CAF3003
Display: 1CAF3003
Used by:
Cause: The lead element data is incorrect.
Remedy: Ensure that the lead range, including lead width, length, and center tolerance, does not overlap.
------------------------------
Code: 1CAF3005
第 1201 页
Display: 1CAF3005
Used by:
Cause: The defined lead elements do not match with the detected elements.
Remedy: Check the following items in element data.
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CAF3006
Display: 1CAF3006
Used by:
Cause: The number of detected leads differs from the number of leads specified in element data.
Remedy: Check the following part data items.
帴Vision height offset
帴No. of leads
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CAF3007
Display: 1CAF3007
Used by:
Cause: Failed to detect any leads.
Remedy: Ensure that the part pick-up position is not excessively out. If the pick-up position is okay,
check the following element data items.
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CB01001
Display: 1CB01001
Used by: GL541
Cause: The fluorescent plate cannot be found.
Remedy: Check the jig. Confirm that the fluorescent plate is being lit by checking the acquired image.
------------------------------
Code: 1CB01002
Display: 1CB01002
Used by: GL541
Cause: The fluorescent plate is dirty.
Remedy: Clean the fluorescent plate or change the nozzle.
------------------------------
Code: 1CB01003
第 1202 页
Display: 1CB01003
Used by: GL541
Cause: The jig cannot be found.
Remedy: Check that the correct jig is being used.
------------------------------
Code: 1CB01004
Display: 1CB01004
Used by: GL541
Cause: The inclination of the jig could not be measured.
Remedy: Check that the correct jig is being used.
------------------------------
Code: 1CB01005
Display: 1CB01005
Used by: GL541
Cause: The jig is tilted more than 5 deg..
Remedy: Correct the angle of the jig.
------------------------------
Code: 1CB01006
Display: 1CB01006
Used by: GL541
Cause: The jig edge could not be found.
Remedy: Check that the jig is fully illuminated in the acquired image.
------------------------------
Code: 1CB01101
Display: 1CB01101
Used by: GL541
Cause: The camera type specification is incorrect.
Remedy: Specify the correct camera type.
------------------------------
Code: 1CB01102
Display: 1CB01102
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB02001
Display: 1CB02001
Used by: GL541
Cause: The fluorescent plate could not be found.
Remedy: Check the nozzle. Confirm that the fluorescent plate is being lit by checking the acquired image.
------------------------------
Code: 1CB02002
Display: 1CB02002
Used by: GL541
Cause: The fluorescent plate is dirty.
Remedy: Clean the fluorescent plate or change the nozzle.
------------------------------
Code: 1CB02003
Display: 1CB02003
Used by: GL541
Cause: The nozzle could not be found.