FUJI错误代码查询 - 第1286页

Used by: Cause: The machine has determined that imaging conditions are not correct. Remedy: Check the component's shape and supply direction. Check the Part data and the Device data. Check the image scanning conditi…

100%1 / 5282
Cause: No leads could be found on the upper side.
Remedy: Check the component's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D0444??
Display: Same as code
Used by:
Cause: The left edge of the component's body could not be found.
Remedy: Check the component's shape and supply direction. Check the Part data and the Device data.
Check the image scanning conditions.
------------------------------
Code: 1D0445??
Display: Same as code
Used by:
Cause: The lower edge of the component's body could not be found.
Remedy: Check the component's shape and supply direction. Check the Part data and the Device data.
Check the image scanning conditions.
------------------------------
Code: 1D0446??
Display: Same as code
Used by:
Cause: The right edge of the component's body could not be found.
Remedy: Check the component's shape and supply direction. Check the Part data and the Device data.
Check the image scanning conditions.
------------------------------
Code: 1D0447??
Display: Same as code
Used by:
Cause: The upper edge of the component's body could not be found.
Remedy: Check the component's shape and supply direction. Check the Part data and the Device data.
Check the image scanning conditions.
------------------------------
Code: 1D045000
Display: Same as code
Used by:
Cause: The pickup position error (in the X direction) is excessive.
Remedy: Check the manner in which components are supplied.
------------------------------
Code: 1D045080
Display: Same as code
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which components are supplied.
------------------------------
Code: 1D045100
Display: Same as code
Used by:
Cause: Component inclination is excessive.
Remedy: Check the manner in which components are supplied.
------------------------------
Code: 1D046???
Display: Same as code
第 1285 页
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the component's shape and supply direction. Check the Part data and the Device data.
Check the image scanning conditions. In particular, check for soiling of the nozzle, and make sure that
the scanning level is correct.
------------------------------
Code: 1D047???
Display: Same as code
Used by:
Cause: There is a logical error in the processing program. The component cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the component.
Remedy: Check the Part data.
------------------------------
Code: 1D048002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D048100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D048110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D048111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D048112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D048113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
第 1286 页
Code: 1D048114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D048115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D048120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D048121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D048122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D048123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D0482??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0483??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0484??
第 1287 页