Code: 1D1A4007 Display: Used by: Cause: The size of the part in the Y direction is too large. Remedy: Check the part shape and the orientation of the part. ------------------------------ Code: 1D1A4008 Display: Used by: …

100%1 / 5282
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D19E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D1A0002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D1A4001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D1A4003
Display:
Used by:
Cause: The part could not be detected.
Remedy: Check the image taken by vision processing.
------------------------------
Code: 1D1A4004
Display:
Used by:
Cause: The part could not be detected.
Remedy: Check the image taken by vision processing.
------------------------------
Code: 1D1A4005
Display:
Used by:
Cause: The size of the part in the X direction is too large.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D1A4006
Display:
Used by:
Cause: The size of the part in the X direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
第 1503 页
Code: 1D1A4007
Display:
Used by:
Cause: The size of the part in the Y direction is too large.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D1A4008
Display:
Used by:
Cause: The size of the part in the Y direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D1A8002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large.Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D1A8100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D1A8110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D1A8111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D1A8112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D1A8113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D1A8114
第 1504 页
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D1A8115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D1A8120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D1A8121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D1A8122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D1A8123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D1A82??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1A83??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1A84??
Display:
第 1505 页