Used by: GSP5 Cause: The Proper Data item "186. Cleaner type" is not within specifications (GSP5). Remedy: The Proper Data item "186. Cleaner type" should be set to "0" when the standard cle…

100%1 / 5282
Display: 11022518
Used by: GSP5
Cause: The operation mode for the solder wiper on the screen cleaning unit has been set to an illegal
value.
Remedy: Check "cleaning_wiper_mode" in Proper data.
------------------------------
Code: 11022519
Display: 11022519
Used by: GSP5,GP2,GP3
Cause: The Proper data item "width_max" differs from the maximum board width for the machine size
(4000, 3000, 2000, 5000).
Remedy: Check the Proper data item "width_max".
------------------------------
Code: 1102251A
Display: 1102251A
Used by: GSP5
Cause: 139. Max Limit Position S Holder and 140. Min Limit Position S Holder in Proper data are set to
0.
Remedy: Check the Proper data. Measure the missing Proper data items and then retransmit the Proper
data.
------------------------------
Code: 1102251B
Display: 1102251B
Used by: GSP5
Cause: The Solder Port No (solder supply unit communication port) in Proper data is incorrectly
specified.
Remedy: After correcting the Solder Port No at the MCS, retransmit the Proper data. Specify the number
of the communication board to which the communication cable for the solder supply unit is connected.
------------------------------
Code: 1102251C
Display: 1102251C
Used by: GSP5
Cause: 142. Squeegee_type in Proper data is incorrectly specified.
Remedy: The initial two bits in Squeegee_type cannot be set simultaneously to 1 (i.e. 1100 0000 0000
0000). If this is done both print pressure feedback mode and manual measurement mode are specified.
When using manual measurement mode, print pressure feedback mode cannot be used. Use automatic
measurement mode when print pressure feedback mode is being used.
Manual measurement mode is specified as 1000 0000 0000 0000.
Print pressure feedback mode is specified as 0100 0000 0000 0000.
Automatic measurement mode is specified as 0000 0000 0000 0000.
------------------------------
Code: 1102251D
Display: 1102251D
Used by: GSP5,GP551,GP6
Cause: This machine is not compatible with the solder supply unit. However, the Proper data item 182.
Solder Auto Supply Type is set to indicate that the machine is compatible with the solder supply unit.
Remedy: Check the Proper data. Check if the optional board (FH1001B) is installed in the machine or if
the input SSD_CFG is on.
------------------------------
Code: 1102251E
Display: 1102251E
第 151 页
Used by: GSP5
Cause: The Proper Data item "186. Cleaner type" is not within specifications (GSP5).
Remedy: The Proper Data item "186. Cleaner type" should be set to "0" when the standard cleaner is
used. When the cleaning unit has been retrofitted, the last bit must be set to "1". Check the Proper Data
and that I/O input 1212 (optional board) CLEANER TYPE is on and then retransmit.
------------------------------
Code: 1102251F
Display: Same as code
Used by: GP551,GP6
Cause: The unloading timer setting is outside the valid range.
Remedy: Make sure that the "ssd_timer" parameter in the Proper data is set to a value from 0.1 to 60
[sec].
------------------------------
Code: 11022520
Display: Same as code
Used by: GP6
Cause: The solder supply speed specified in the Proper data is outside the valid range.
Remedy: Make sure that the "Solder_Supply_speed" parameter in the Proper data is set to a value from 0
to 200 [mm/sec].
------------------------------
Code: 11022521
Display: Same as code.
Used by: GP551
Cause: For machines equipped with double squeegees, double-sided cleaning cannot be performed
during automatic operation.
Remedy: At Proper data item "202. Cleaner type", specify only the lower cleaner for use during automatic
operation.
------------------------------
Code: 11022522
Display: Same as code.
Used by:
Cause: A cleaning action has been attempted on a machine that is not equipped with cleaners or, double-
sided cleaning has been attempted on a machine equipped only with a lower cleaner.
Remedy: Ensure that the settings in Proper data reflect machine configuration.
------------------------------
Code: 11022523
Display: Same as code.
Used by: GP551,GP6
Cause: Cleaning method is not specified or incorrect value has been entered.
Remedy: Ensure if "cleaning method no.0,1,2" in Proper Data satisfy the following requirements.
More than six characters.
Available characters; Y,N,E and C. Lower case characters are not available.
Terminate code "E" is used.
------------------------------
Code: 11022600
Display:
Used by: IP1,IP2
Cause: The data does not match machine specifications (IP, IP2).
Remedy: Check the Proper data to ensure that the Proper data in the file is the Proper data for the
machine.
1. Print out the Proper, and after inputting new Proper, transmit this to the machine.
第 152 页
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
4. If the machine is an IP-1 using MCS/1, input a number other than 0 into Proper data's "Identity" item.
------------------------------
Code: 11022601
Display: 11022601
Used by: IP2
Cause: The Proper data item Nozzle size LL is set to 0 (FIP2).The nozzle size item "Nozzle size LL" in
Proper data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022602
Display: 11022602
Used by: IP2
Cause: The Proper data item Nozzle size L is set to 0 (FIP2).The nozzle size item "Nozzle size L" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022603
Display: 11022603
Used by: IP2
Cause: The Proper data item Nozzle size M is set to 0 (FIP2).The nozzle size item "Nozzle size M" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022604
Display: 11022604
Used by: IP2
Cause: The Proper data item Nozzle size S is set to 0 (FIP2).The nozzle size item "Nozzle size S" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022605
Display:
Used by: IP2
Cause: The Proper data item ccd level is set to 0 (IP2).
Remedy: Re-measure the CCD level and re-transmit Proper data.
------------------------------
Code: 11022606
Display:
Used by: IP1,IP2
Cause: The Proper data item max.speed_? is out of range (IP1).
Remedy: Check the Proper data item max.speed_?. The acceptable range is from 0% to 100%. Re-
transmit after changing Proper data.
------------------------------
Code: 11022607
Display:
Used by: IP1,IP2
Cause: The Proper data item Middle_? is out of range (IP1).
Remedy: Check the Proper data item Middle_?. The acceptable range is from 5 pulses to 500 pulses. Re-
transmit after changing Proper data.