FUJI错误代码查询 - 第1622页
Code: 1D2F8120 Display: Same as code Used by: Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part data. Remedy: Set a value for the "Qty 0" para…
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D2F8100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D2F8110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D2F8111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D2F8112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D2F8113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D2F8114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D2F8115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
第 1621 页
Code: 1D2F8120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D2F8121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D2F8122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D2F8123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.
Remedy: Set a value for the "Qty 3" parameter.
------------------------------
Code: 1D2F82??
Display: Same as code.
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F83??
Display: Same as code.
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F84??
Display: Same as code.
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F85??
Display: Same as code.
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
第 1622 页
------------------------------
Code: 1D2F88??
Display: Same as code.
Used by:
Cause: A lead on the left side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F89??
Display: Same as code.
Used by:
Cause: A lead on the left side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F8A??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F8B??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F8C??
Display: Same as code.
Used by:
Cause: A lead on the right side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F8D??
Display: Same as code.
Used by:
Cause: A lead on the right side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F8E??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F8F??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D2F90??
Display: Same as code.
第 1623 页