FUJI错误代码查询 - 第173页
Code: 11022A23 Display: Same as code Used by: QP242,QP201,QP202,QP203 Cause: The "PLM? VP board No. (QP2)" setting (which indicates the number of the vision processing board that the LSO board is connected to) …
------------------------------
Code: 11022A1D
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The board quantity specified for vision processing is outside the valid range.
Remedy: Set a value from 1 to 6 for "The Number of Vision Processor (QP2)" in the Proper data.
------------------------------
Code: 11022A1E
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Parts Camera Type (QP2)" setting (which indicates the vision processing camera type)
is outside the valid range. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct camera type for the "PLM? Parts Camera Type (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A1F
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Mark Camera MPX ch. No. (QP2)" setting (which indicates the number of the
multiplexer port that the mark camera is connected to) either is outside the valid range, or duplicates
another setting. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct port number (a value from 1 to 12) for the "PLM? Mark Camera MPX ch. No.
(QP2)" parameter in the Proper data.
------------------------------
Code: 11022A20
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Parts Camera MPX ch. No. (QP2)" setting (which indicates the number of the
multiplexer port that the RS vision processing camera is connected to) either is outside the valid range, or
duplicates another setting. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct port number (a value from 1 to 12) for the "PLM? Parts Camera MPX ch. No.
(QP2)" parameter in the Proper data.
------------------------------
Code: 11022A21
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? LSO ch. No. (QP2)" setting (which indicates the number of the LSO board port that the
LS vision processing camera is connected to) either is outside the valid range, or duplicates another
setting. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct port number (a value from 1 to 4) for the "PLM? LSO ch. No. (QP2)" parameter in
the Proper data.
------------------------------
Code: 11022A22
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? LSO board No. (QP2)" setting (which indicates the number of the LSO board that the
LS vision processing camera is connected to) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set the correct board number (either 1 or 2) for the "PLM? LSO board No. (QP2)" parameter in
the Proper data.
------------------------------
第 172 页
Code: 11022A23
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? VP board No. (QP2)" setting (which indicates the number of the vision processing
board that the LSO board is connected to) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set the correct board number (either 1 or 2) for the "PLM? VP board No. (QP2)" parameter in the
Proper data.
------------------------------
Code: 11022A24
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Camera? Scan Speed (QP2)" setting (which indicates the scan speed for the LS camera)
is outside the valid range. The value for the "?" in the parameter name indicates the module number and
camera number.
Remedy: Set the correct value (from 1 to 1000) for the "PLM? Camera? Scan Speed (QP2)" parameter in
the Proper data.
------------------------------
Code: 11022A25
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Scan Offset Pulse (H,M,L) (QP2)" setting (which indicates the offset for the start of
scanning by the LS camera) is outside the valid range. The value for the "?" in the parameter name
indicates the module number.
Remedy: Set the correct value (from 1 to 60000) for the "PLM? Scan Offset Pulse (H,M,L) (QP2)" parameter
in the Proper data.
------------------------------
Code: 11022A26
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the "PLM? Pickup Timer ,2,3 (QP2)" parameter, which determines how
long the head remains lowered during component pickup. The value for the "?" in the parameter
nameindicates the module number.
Remedy: Set a value for the "PLM? Pickup Timer ,2,3 (QP2)" in the Proper data.
------------------------------
Code: 11022A27
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the "PLM? Placement Timer ,2,3 (QP2)" parameter, which determines
how long the head remains lowered during component placement. The value for the "?" in the parameter
name indicates the module number.
Remedy: Set a value for the "PLM? Placement Timer ,2,3 (QP2)" in the Proper data
------------------------------
Code: 11022A28
Display: Same as code
Used by: QP242
Cause: No value has been set for the "PLM? Feeding On Timer (QP2)" parameter, which determines how
long feeding by the IP-series feeder is turned on. The value for the "?" in the parameter name indicates the
module number.
Remedy: Set a value for the "PLM? Feeding On Timer (QP2)" in the Proper data
------------------------------
第 173 页
Code: 11022A29
Display: Same as code
Used by: QP242
Cause: No value has been set for the "PLM? Feeding Off Timer (QP2)" parameter, which determines how
long feeding by the IP-series feeder is turned off. The value for the "?" in the parameter name indicates the
module number.
Remedy: Set a value for the "PLM? Feeding Off Timer (QP2)" in the Proper data
------------------------------
Code: 11022A2A
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX In Convyr Speed (QP2)" setting (which determines the speed of the board conveyer
PX-axis during board loading) is outside the valid range. The value for the "?" in the parameter name
indicates the module number.
Remedy: Set a value from 38 to 1000 for the "PLM? PX In Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2B
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX Out Convyr Speed (QP2)" setting (which determines the speed of the board
conveyer PX-axis during board unloading) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set a value from 38 to 1000 for the "PLM? PX Out Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2C
Display: Same as code
Used by: QP242,QP202
Cause: The "PLM? PX Red Convyr Speed (QP2)" setting (which determines the speed of the board
conveyer PX-axis during board deceleration) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set a value from 5 to 37 for the "PLM? PX Red Convyr Speed (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A2D
Display: "Data check error [11022A2D]"
Used by: QP242,QP201,QP202,QP203
Cause: The number of the communication port to be used by the ID controller unit either has not been
set, or duplicates another setting.
Remedy: Check the number of the port being used and correct the setting.
------------------------------
Code: 11022A2E
Display: "Data check error [11022A2E]"
Used by: QP242
Cause: The number of the communication port to be used by the tape end sensor either has not been set,
or duplicates another setting.
Remedy: Check the number of the port being used and correct the setting.
------------------------------
Code: 11022A2F
Display: "Data check error [11022A2F]"
第 174 页