FUJI错误代码查询 - 第1744页

Remedy: Set a value for the "Body_size 1" parameter. ------------------------------ Code: 1D428115 Display: Same as code Used by: Cause: No value has been set for the "Body_size 0" parameter (the body…

100%1 / 5282
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is too large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D428002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D428100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D428110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D428111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D428112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D428113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D428114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
第 1743 页
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D428115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D428120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D428121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D428122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D428123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.
Remedy: Set a value for the "Qty 3" parameter.
------------------------------
Code: 1D4282??
Display: Same as code.
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D4283??
Display: Same as code.
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D4284??
Display: Same as code.
第 1744 页
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D4285??
Display: Same as code.
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D4288??
Display: Same as code.
Used by:
Cause: A lead on the left side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D4289??
Display: Same as code.
Used by:
Cause: A lead on the left side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D428A??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D428B??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D428C??
Display: Same as code.
Used by:
Cause: A lead on the right side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D428D??
Display: Same as code.
Used by:
Cause: A lead on the right side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D428E??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
第 1745 页