FUJI错误代码查询 - 第1775页

Cause: Unable to detect parts. Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead pitch values in Part data. ------------------------------ Code: 1D66000A Display: Used …

100%1 / 5282
Used by:
Cause: Unable to pick parts.
Remedy: Replenish the parts supply.
------------------------------
Code: 1D660003
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660004
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660005
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660006
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660007
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660008
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660009
Display:
Used by:
第 1774 页
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000A
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000B
Display:
Used by:
Cause: The X length of the part is not within the acceptable range.
Remedy: Check the shape of the part.
------------------------------
Code: 1D66000C
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000D
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000E
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D66000F
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660010
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
第 1775 页
------------------------------
Code: 1D660011
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660012
Display:
Used by:
Cause: The Y length of the part is not within the acceptable range.
Remedy: Check the shape of the part.
------------------------------
Code: 1D660013
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660014
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660015
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660016
Display:
Used by:
Cause: Unable to detect parts.
Remedy: Check the image taken by vision processing. check the body size X/Y, number of leads and lead
pitch values in Part data.
------------------------------
Code: 1D660017
Display:
Used by:
Cause: Vision processing could not take a normal image. The upper or lower areas were too uneven or
there was foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D660018