FUJI错误代码查询 - 第185页
Display: Used by: Cause: __mcs_version was set for VQ. During execution of VQ a format error occurred in MCS or at the machine. Remedy: Check that the transmission cable is not disconnected. Re-transmit the data. -------…
Remedy: None.
------------------------------
Code: 11060017
Display:
Used by:
Cause: The line number is set outside the range 0~Z.
Remedy: None.
------------------------------
Code: 11060018
Display:
Used by:
Cause: The transmitted data was longer than specified.
Remedy: None.
------------------------------
Code: 1106001A
Display:
Used by:
Cause: The received message level mask is finished.
Remedy: None.
------------------------------
Code: 1106001B
Display:
Used by:
Cause: The program could not be transmitted in automatic operation.
Remedy: Interrupt automatic operation.
------------------------------
Code: 1106001C
Display:
Used by:
Cause: The data could not be changed in automatic operation.
Remedy: Interrupt automatic operation.
------------------------------
Code: 1106001D
Display:
Used by:
Cause: The garbage could not be collected in automatic operation.
Remedy: Interrupt automatic operation.
------------------------------
Code: 1106001E
Display:
Used by:
Cause: The Proper could not be transmitted in automatic operation.
Remedy: Interrupt automatic operation.
------------------------------
Code: 1106001F
Display:
Used by:
Cause: The Status data could not be transmitted in automatic operation.
Remedy: Interrupt automatic operation.
------------------------------
Code: 11060020
第 184 页
Display:
Used by:
Cause: __mcs_version was set for VQ. During execution of VQ a format error occurred in MCS or at the
machine.
Remedy: Check that the transmission cable is not disconnected. Re-transmit the data.
------------------------------
Code: 11060022
Display:
Used by:
Cause: Data could not be skipped in automatic operation.
Remedy: Interrupt automatic operation.
------------------------------
Code: 11060024
Display:
Used by:
Cause: There is no specified module for data skip.
Remedy: None.
------------------------------
Code: 11060025
Display:
Used by:
Cause: The reference for the data skip module is incorrect.
Remedy: None.
------------------------------
Code: 11060027
Display:
Used by:
Cause: There is no specified module for garbage collection.
Remedy: None.
------------------------------
Code: 11060028
Display:
Used by:
Cause: There is no specified module for data transmitted from the machine.
Remedy: None.
------------------------------
Code: 11060029
Display:
Used by:
Cause: The reference for the module for data transmitted from the machine is incorrect.
Remedy: None.
------------------------------
Code: 11060030
Display:
Used by:
Cause: Data cannot be changed (empty bit) while receiving dB.
Remedy: None.
------------------------------
Code: 11060031
Display:
Used by:
第 185 页
Cause: There is no data change name while receiving dB.
Remedy: None.
------------------------------
Code: 1106003F
Display:
Used by:
Cause: The version number of the previous transmission is different from the current version number.
Remedy: Reset-start the machine.
------------------------------
Code: 11060040
Display: TVX11060040
Used by:
Cause: When one line was transmitted, the specified machine did not exist. Check the program at the
machine.
Remedy: Check the program at the machine.
------------------------------
Code: 11060041
Display: TVX11060041
Used by:
Cause: When one line was transmitted, the specified program was in automatic operation in foreground.
Remedy: Interrupt automatic operation and transmit the line again.
------------------------------
Code: 11060042
Display: TVX11060042
Used by:
Cause: When one line transmission is attempted, the line and the program sequence number differ.
Remedy: The number of sequences in the program have changed and the entire program must be
retransmitted.
------------------------------
Code: 11060043
Display: TVX11060043
Used by:
Cause: tV was transmitted before tQ.
Remedy: None.
------------------------------
Code: 11060061
Display: 11060061
Used by:
Cause: A remote block skip instruction is not possible during automatic operation.
Remedy: Exit automatic operation, then retransmit.
------------------------------
Code: 11060062
Display: 11060062
Used by:
Cause: A program does not exist in the foreground (number 0 position) on the machine.
Remedy: Transmit a program to the foreground (number 0 position) of the machine.
------------------------------
Code: 11060064
Display:
Used by:
Cause: When skip or data change is attempted, the operation cannot be attempted even though the
第 186 页