FUJI错误代码查询 - 第1851页

Used by: Cause: The line monitor could not be opened. Remedy: Check that the pipe exists. If it does not, re-boot MCS. ------------------------------ Code: 21000012 Display: machine port open error (****) Used by: Cause:…

100%1 / 5282
------------------------------
Code: 21000009
Display: Transmition pipe open error (****)
Used by:
Cause: The transmission pipe could not be opened.
Remedy: If there is no pipe, re-boot MCS.
------------------------------
Code: 2100000A
Display: Mother pipe open error (****)
Used by:
Cause: The mother pipe could not be opened.
Remedy: Check the pipe. If there is no pipe, reboot MCS.
------------------------------
Code: 2100000B
Display: Transmition error (dA) (****)
Used by:
Cause: dA transmission could not be carried out.
Remedy: Check that the machine power is on and that the cables are connected properly.
------------------------------
Code: 2100000C
Display: Terminal pipe open error (****)
Used by:
Cause: The terminal pipe could not be opened.
Remedy: Check the terminal pipe. If it is not there, re-boot MCS.
------------------------------
Code: 2100000D
Display: can't Find line or MC nick name (****)
Used by:
Cause: The specified line name or machine nickname is incorrect.
Remedy: Check the line descriptor and nickname and repeat the input.
------------------------------
Code: 2100000E
Display: Log File read error (****)
Used by:
Cause: The log file could not be read.
Remedy: Check the log file.
------------------------------
Code: 2100000F
Display: Log File directory create error (****)
Used by:
Cause: The log file directory could not be created.
Remedy: Check the machine nickname entered in the line descriptor.
------------------------------
Code: 21000010
Display: loglist pipe open error (****)
Used by:
Cause: The loglist pipe could not be opened.
Remedy: Check that there is a pipe. If there is no pipe, re-boot MCS.
------------------------------
Code: 21000011
Display: Line_monitor pipe open error (****)
第 1850 页
Used by:
Cause: The line monitor could not be opened.
Remedy: Check that the pipe exists. If it does not, re-boot MCS.
------------------------------
Code: 21000012
Display: machine port open error (****)
Used by:
Cause: The machine port could not be opened.
Remedy: Change the port.
------------------------------
Code: 21000013
Display: Environment file read error (****)
Used by:
Cause: The environment file could not be read.
Remedy: Check that the environment file exists.
------------------------------
Code: 21000014
Display: Packing pipe open error (****)
Used by:
Cause: The packing pipe could not be opened.
Remedy: Check that the packing pipe exists. If it does not, re-boot MCS.
------------------------------
Code: 21000015
Display: Packing pipe write error (****)
Used by:
Cause: The packing pipe could not write.
Remedy: Check that the packing pipe exists. If it does not, re-boot the system.
------------------------------
Code: 21000016
Display: Error XXXX report from M/C
Used by:
Cause: Error code XXXX was received from the machine.
Remedy: Find error code XXXX in the directory.
------------------------------
Code: 21000017
Display: version change error
Used by:
Cause: The machine version was changed.
Remedy: Reset the MCS.
------------------------------
Code: 21000018
Display: sep_log pipe open error
Used by:
Cause: The pipe could not be opened.
Remedy: Re-boot MCS.
------------------------------
Code: 21000019
Display: logfile separate error
Used by:
Cause: There was a logfile separate error.
Remedy: Re-execute the function.
第 1851 页
------------------------------
Code: 2100001A
Display: Timer_ev link error
Used by:
Cause: The timer event could not be linked.
Remedy: Reboot MCS.
------------------------------
Code: 2100001B
Display: Strings file expand error (***)
Used by:
Cause: The message file could not be expanded.
Remedy: Reboot MCS. If the problem persists, reinstall the system.
------------------------------
Code: 2100001C
Display: Logfile save error
Used by:
Cause: The log file could not be written to the hard disk.
Remedy: Check how much space remains in the hard disk. Check the disk partitions. If there is not
enough remaining space, delete all unnecessary files and check that the disk is in good condition. If the
error recurs and there is space available, it is possible that the disk is damaged.
------------------------------
Code: 2100001D
Display: Version error machine No. **(****)
Used by:
Cause: The data already in the machine interfered with the data in the version being transmitted to the
machine.
Remedy: Reset-start the machine (machine No.**) and re-boot MCS.
------------------------------
Code: 2100001E
Display: Version check time over
Used by:
Cause: The version being transmitted to the machine could not be checked.
Remedy: Turn off the machine power, re-boot MCS, re-boot the machine and re-transmit the version.
------------------------------
Code: 2100001F
Display:
Used by:
Cause: The production event file could not be read.
Remedy: Reinstall and reboot MCS. If this error recurs, there is the possibility that the file is damaged.
------------------------------
Code: 21001000
Display:
Used by:
Cause: The transmission sub-process could not be carried out due to a system error.
Remedy: Re-install the Host communication software.
------------------------------
Code: 21001041
Display: Illegal function code/command
Used by:
Cause: The start-up command was incorrect.
Remedy: Correct the specified start-up command.