------------------------------ Code: 21006500 Display: Illegal parameter Used by: Cause: The specified start-up parameter is illegal. Remedy: Re-install the software. ------------------------------ Code: 21006501 Display…

100%1 / 5282
------------------------------
Code: 2100640E
Display: this file is not a program
Used by:
Cause: The specified file is not a production program.
Remedy: Check the production programs.
------------------------------
Code: 2100640F
Display: this file is not a PST
Used by:
Cause: The specified file is not a permanent set table.
Remedy: Check the file.
------------------------------
Code: 21006410
Display: can't open output PST file
Used by:
Cause: The output permanent set table cannot be opened.
Remedy: Check that the write protect setting is not on. Also, check that the hard disk has sufficient
memory.
------------------------------
Code: 21006411
Display: can't create output PST file
Used by:
Cause: The output permanent set table cannot be created.
Remedy: Check that the write protect setting is not on. Also, check that the hard disk has sufficient
memory.
------------------------------
Code: 21006412
Display: can't write output PST file
Used by:
Cause: The output permanent set table cannot be written.
Remedy: Check that the write protect setting is not on. Also, check that the hard disk has sufficient
memory.
------------------------------
Code: 21006413
Display: WARNING!!****: Cartridge name isn't registered inpart data
Used by:
Cause: The feeder is not registered in part data.
Remedy: This message has no effect on processing. However, check the feeder settings in Part data.
------------------------------
Code: 21006414
Display: can't open part data file
Used by:
Cause: Part data file cannot be opened.
Remedy: Contact Fuji.
------------------------------
Code: 21006415
Display: can't read separator data file
Used by:
Cause: The separator data file cannot be read.
Remedy: Re-install the software.
第 1909 页
------------------------------
Code: 21006500
Display: Illegal parameter
Used by:
Cause: The specified start-up parameter is illegal.
Remedy: Re-install the software.
------------------------------
Code: 21006501
Display: message file read error
Used by:
Cause: There is a message file read error.
Remedy: Re-execute the function. If it still doesn't work, re-install the software.
------------------------------
Code: 21006502
Display: console pipe open error
Used by:
Cause: Unable to open a console path.
Remedy: Re-install the software.
------------------------------
Code: 21006503
Display: CRT semaphore link error
Used by:
Cause: The terminal event could not be linked.
Remedy: Re-execute the function. If it still doesn't work, re-install the software.
------------------------------
Code: 21006505
Display: Separator Standerd File read error
Used by:
Cause: Unable to read the separator standard file.
Remedy: Check the Std file.
------------------------------
Code: 21006506
Display: Source file read error
Used by:
Cause: There was a source file read error.
Remedy: Check the source file.
------------------------------
Code: 21006507
Display: Program file open error
Used by:
Cause: Unable to open the production program.
Remedy: Check the production program.
------------------------------
Code: 21006508
Display: Memory full
Used by:
Cause: There is not enough memory.
Remedy: Check how much available memory is left. If other modules have been started up, wait until
they are finished. Otherwise, re-boot MCS.
------------------------------
Code: 21006509
第 1910 页
Display: Separator frame open error
Used by:
Cause: Unable to open the production program.
Remedy: Check the production program.
------------------------------
Code: 2100650A
Display: Separator frame read error
Used by:
Cause: Production program read error.
Remedy: Check the production program.
------------------------------
Code: 2100650B
Display: Separator frame write error
Used by:
Cause: Production program write error.
Remedy: Check that the write protect setting is not on.
------------------------------
Code: 2100650C
Display: Machine_type_table read error
Used by:
Cause: Machine type read error.
Remedy: Re-install the software.
------------------------------
Code: 2100650D
Display: Machine_type_table open error
Used by:
Cause: Machine type table open error.
Remedy: Re-install the software.
------------------------------
Code: 2100650F
Display: Program file copy error
Used by:
Cause: Production program copy error.
Remedy: Check that the write protect setting is not on.
------------------------------
Code: 21006510
Display: Device queue data not found
Used by:
Cause: The device queue was not found.
Remedy: Re-install the software.
------------------------------
Code: 21006511
Display: Special condition file read error
Used by:
Cause: Special condition file read error.
Remedy: Check the special condition file.
------------------------------
Code: 21006512
Display: special condition file open error
Used by:
Cause: Special condition file open error.
第 1911 页