------------------------------ Code: 21006524 Display: frame status FIX 'base' Used by: Cause: The base frame status is a fixed device. Remedy: Check the settings of the permanent set and special variables file…
------------------------------
Code: 2100651C
Display: offset_table read error
Used by:
Cause: Offset table read error.
Remedy: Re-install the software.
------------------------------
Code: 2100651D
Display: program_file open error
Used by:
Cause: Production program open error.
Remedy: Check the production program.
------------------------------
Code: 2100651E
Display: program_file read error
Used by:
Cause: Production program read error.
Remedy: Check the production program.
------------------------------
Code: 2100651F
Display: program_file write error
Used by:
Cause: Production program write error.
Remedy: Check that the write protect setting is not on.
------------------------------
Code: 21006520
Display: defferent data 'd_comment' and 'part name'
Used by:
Cause: The destination machine had these settings, and there is a difference in the d_comments and the
Part data between the base machine and the destination machine.
Remedy: This is a warning. Production will continue.
------------------------------
Code: 21006521
Display: defferent data 'd_comment'
Used by:
Cause: When the next machine had these settings, there is a difference in the d_comments between the
base machine and the destination machine.
Remedy: This is a warning. Production will continue.
------------------------------
Code: 21006522
Display: defferent data 'part name'
Used by:
Cause: When the next machine had these settings, there is a difference in the part name between the
base machine and the destination machine.
Remedy: This is a warning. Production will continue.
------------------------------
Code: 21006523
Display: frame status FIX 'base' and 'distination'
Used by:
Cause: The base move and the destination move's frame status is different.
Remedy: Check the settings of the permanent set and special variables files.
第 1913 页
------------------------------
Code: 21006524
Display: frame status FIX 'base'
Used by:
Cause: The base frame status is a fixed device.
Remedy: Check the settings of the permanent set and special variables files.
------------------------------
Code: 21006525
Display: frame status FIX 'destination'
Used by:
Cause: The destination frame status is a fixed device.
Remedy: Check the settings of the permanent set and special variables files.
------------------------------
Code: 21006526
Display: No separation machine
Used by:
Cause: There is no machine to separate to.
Remedy: Check the structure of the line and the source program.
------------------------------
Code: 21006527
Display: M/C not defined in Sep_data block of Parta Data
Used by:
Cause: The next machine is not registered in Part data.
Remedy: Check Sep_data in Part data.
------------------------------
Code: 21006528
Display: Mark sequence is nothing
Used by:
Cause: Either the base or the destination machine has no mark sequence.
Remedy: Check the source program.
------------------------------
Code: 21006529
Display: different block#, position in mark sequence
Used by:
Cause: The mark sequence block number is not the same as the coordinate specification.
Remedy: Check the source program.
------------------------------
Code: 2100652A
Display: different block# in mark sequence
Used by:
Cause: The mark sequence is in a different block.
Remedy: Check the source program.
------------------------------
Code: 2100652B
Display: different position in mark sequence
Used by:
Cause: The mark sequence coordinate position is wrong.
Remedy: Check the source program.
------------------------------
Code: 2100652C
Display: distination frame status is CLOSE
第 1914 页
Used by:
Cause: The destination frame status is closed.
Remedy: Change the destination or the device number.
------------------------------
Code: 2100652D
Display: Can't move same Machine
Used by:
Cause: The base and destination are the same machine.
Remedy: Check the destination machine's specified input.
------------------------------
Code: 2100652E
Display: No Separation Machine
Used by:
Cause: There is no separation machine.
Remedy: Check the machines.
------------------------------
Code: 2100652F
Display: No device position
Used by:
Cause: There is no available device position.
Remedy: Check the base production program.
------------------------------
Code: 21006530
Display: Device queue enpty
Used by:
Cause: The device queue is empty.
Remedy: Check the device data in the base and destination production programs.
------------------------------
Code: 21006531
Display: No entry machine in part_data
Used by:
Cause: The specified destination machine is not registered in Part data.
Remedy: Check Sep_data in Part data.
------------------------------
Code: 21006532
Display: Cartridge is empty
Used by:
Cause: The number of feeders in the special variables file exceeds the limit.
Remedy: Change the base machine.
------------------------------
Code: 21006533
Display: front frame occupancy error
Used by:
Cause: When a feeder was moved to a specified base device number, the front frame was occupied.
Remedy: Change the destination machine device number.
------------------------------
Code: 21006534
Display: back frame occupancy error
Used by:
Cause: When a feeder was moved to a specified destination device number, the back frame was occupied.
Remedy: Change the base machine device number.