FUJI错误代码查询 - 第1931页
Display: File offset get error Used by: Cause: The file offset cannot be obtained. Remedy: Re-install the software. ------------------------------ Code: 2100740C Display: MTT file seek error Used by: Cause: Unable to see…
Remedy: Check the file.
------------------------------
Code: 21007403
Display: Message file read error
Used by:
Cause: Unable to read the message file.
Remedy: Re-install the software.
------------------------------
Code: 21007404
Display: Read pipe create error
Used by:
Cause: Unable to open the pipe.
Remedy: Re-boot MCS.
------------------------------
Code: 21007405
Display: Write pipe create error
Used by:
Cause: Unable to open the pipe.
Remedy: Re-boot MCS.
------------------------------
Code: 21007406
Display: CRT event link error
Used by:
Cause: Unable to link the CRT event.
Remedy: Re-boot MCS.
------------------------------
Code: 21007407
Display: MTT file get error
Used by:
Cause: Unable to read the machine type table.
Remedy: Re-install the software.
------------------------------
Code: 21007408
Display: MTT file not found
Used by:
Cause: MTT file not found.
Remedy: Re-install the software.
------------------------------
Code: 21007409
Display: MTT file open error
Used by:
Cause: Unable to open the machine type table.
Remedy: Re-install the system.
------------------------------
Code: 2100740A
Display: Memory alocation error
Used by:
Cause: Unable to allocate memory.
Remedy: Re-boot MCS.
------------------------------
Code: 2100740B
第 1930 页
Display: File offset get error
Used by:
Cause: The file offset cannot be obtained.
Remedy: Re-install the software.
------------------------------
Code: 2100740C
Display: MTT file seek error
Used by:
Cause: Unable to seek the file.
Remedy: Re-install the software.
------------------------------
Code: 2100740D
Display: Production file read err
Used by:
Cause: Unable to read the production program.
Remedy: Check the filename and the file.
------------------------------
Code: 2100740E
Display: Part data read error
Used by:
Cause: Unable to read the Part data.
Remedy: Check the filename and the file.
------------------------------
Code: 2100740F
Display: Cartridge name create err
Used by:
Cause: Unable to create feeder names.
Remedy: Check that the information in Part data's Package_and_appearance_data is entered correctly.
------------------------------
Code: 21007410
Display: Queue data create error
Used by:
Cause: Unable to save the memory.
Remedy: Re-boot MCS.
------------------------------
Code: 21007411
Display: Dequeing error
Used by:
Cause: Unable to de-queue memory.
Remedy: Re-boot MCS.
------------------------------
Code: 21007412
Display: Queueing error
Used by:
Cause: Unable to queue data.
Remedy: Re-boot MCS.
------------------------------
Code: 21007413
Display: PST file not found
Used by:
Cause: The PST file was not found.
第 1931 页
Remedy: Check the input filename.
------------------------------
Code: 21007414
Display: PST file open error
Used by:
Cause: Unable to read the PST file.
Remedy: Check the file.
------------------------------
Code: 21007415
Display: Offset table read error
Used by:
Cause: Unable to read the file.
Remedy: Check the file and save it.
------------------------------
Code: 21007416
Display: Station over
Used by:
Cause: The device cannot go into the station.
Remedy: Join the feeders. Alternately, stop using the PST and base program.
------------------------------
Code: 21007417
Display: Cartridge data read error
Used by:
Cause: Unable to read feeder data.
Remedy: Check the Part data input headings.
------------------------------
Code: 21007418
Display: coefficient read error
Used by:
Cause: The fixed device was to have been placed where it could not be placed.
Remedy: Depending on the feeder width, there are cases where the feeders cannot be placed on the ends
of the stations. Change the location.
------------------------------
Code: 21007419
Display: Occupancy error
Used by:
Cause: The fixed device table tried to place devices where they could not be placed.
Remedy: Depending on the feeder width, there are cases where the feeders cannot be placed next to each
other. Change the location.
------------------------------
Code: 2100741A
Display: Slot info read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100741B
Display: Occupancy data not found
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
第 1932 页