Display: Skip device mount error Used by: Cause: There are too many skipped devices at the station, so the devices cannot be arranged. Remedy: Skipped devices cannot be overwritten to an output file. --------------------…
Remedy: Re-install the machine type table.
------------------------------
Code: 2100782D
Display: Can not generate cartridge name
Used by:
Cause: The feeder could not be automatically generated from Part data.
Remedy: Edit Part data at the editor.
------------------------------
Code: 2100782E
Display: Not used Cartridge
Used by:
Cause: The feeder types are not registered in the machine type table.
Remedy: Use feeders which have been registered in the machine type table.
------------------------------
Code: 2100782F
Display: Can not feedback Fix device
Used by:
Cause: Could not receive feedback from fixed devices.
Remedy: Fix the permanent set table device numbers and device comments at the editor.
------------------------------
Code: 21007830
Display: Different cartridge name in PT file
Used by:
Cause: When a fixed device was arranged, an error occurred.
Remedy: Put the same feeder names in the PT file and the input program's specified devices.
------------------------------
Code: 21007831
Display: Not get PD file name
Used by:
Cause: The Part data name could not be obtained from the input program.
Remedy: Edit the input program at the editor.
------------------------------
Code: 21007832
Display: Not get holder number
Used by:
Cause: The holder number could not be obtained.
Remedy: Edit the lead pitch, body size and nozzle name at the device's Part data.
------------------------------
Code: 21007833
Display: St.1 and St.2 device over
Used by:
Cause: There are too many devices at the station, so the devices cannot be arranged.
Remedy: Decrease the number of feeders in the input program.
------------------------------
Code: 21007834
Display: Rtray and Ltray device over
Used by:
Cause: There are too many skipped devices at the station, so the devices cannot be arranged.
Remedy: Decrease the number of feeders in the input program.
------------------------------
Code: 21007835
第 1972 页
Display: Skip device mount error
Used by:
Cause: There are too many skipped devices at the station, so the devices cannot be arranged.
Remedy: Skipped devices cannot be overwritten to an output file.
------------------------------
Code: 21007836
Display: Next device mount error
Used by:
Cause: There are too many next devices at the station, so the devices cannot be arranged.
Remedy: Next devices cannot be overwritten to an output file.
------------------------------
Code: 21007837
Display: Can not make mount sequence
Used by:
Cause: The order of mount sequences cannot normally be changed.
Remedy: None.
------------------------------
Code: 21007838
Display: Strategy file read error
Used by:
Cause: Strategy file read error.
Remedy: Reinstall the system.
------------------------------
Code: 21007839
Display: Cannot make mark sequence
Used by:
Cause: Cannot create mark sequences.
Remedy: Reinstall MCS.
------------------------------
Code: 2100783A
Display: Output file has not sequence
Used by:
Cause: Output file has no sequences.
Remedy: Specify an input program with sequences.
------------------------------
Code: 2100783B
Display: No entry machine name
Used by:
Cause: FIP3 is not registered in Part data's separator data.
Remedy: Register the FIP3 and add FIP3 data in Part data's separator.
------------------------------
Code: 2100783C
Display: "Not get queue position"
Used by:
Cause: This is a system error. It should not occur under normal circumstances.
Remedy: Stop the FIP-III optimizer, then reexecute.
------------------------------
Code: 2100783D
Display: "Undefined cartridge name for device in PT file"
Used by:
Cause: The feeder type cannot be determined, because the feeder type has not been entered in the device
第 1973 页
comment field of the PST file. The feeder type will be determined based on the Part data
Remedy: Use the editor to edit the PST file, and enter a feeder type in the "Device_name" parameter for the
device number in question.
------------------------------
Code: 2100783E
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range. The device
comment in question will be separated as a non-fixed feeder.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100783F
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station. The feeder in question will be
separated as a non-fixed feeder.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007840
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007900
Display: Illegal parameter option
Used by:
Cause: An illegal character has been set as a start parameter.
Remedy: Check the start option and then re-start the machine.
------------------------------
Code: 21007901
Display: Message file read error
Used by:
Cause: The message file cannot be read.
Remedy: Re-install the message file.
------------------------------
Code: 21007902
Display: CRT event link error
Used by:
Cause: The CRT event cannot be linked.
Remedy: Reboot the MCS.
------------------------------
Code: 21007903
Display: Input file open error
Used by:
Cause: The input file cannot be opened.
Remedy: Edit the input file using the editor command.
------------------------------
Code: 21007904