------------------------------ Code: 2100793E Display: Parts height regulation over. Used by: Cause: The part height exceeds the maximum value (6 mm). Remedy: Edit the Part data to ensure that the part height does not ex…
Display: No used Cartridge.
Used by:
Cause: A feeder name which is not registered under station data in the machine type table is in Part
data.
Remedy: Enter the feeder names which are registered under station data in the machine type table in Part
data.
------------------------------
Code: 21007937
Display: Not set cartridge name.
Used by:
Cause: The feeder name cannot be obtained from Part data.
Remedy: Enter the feeder name in Part data.
------------------------------
Code: 21007938
Display: Not set nozzle size.
Used by:
Cause: An error occurred while checking the nozzle size for each part in Part data and the nozzle
assignment table.
Remedy: Check that the nozzle sizes set in Part data are in the nozzle assignment table.
------------------------------
Code: 21007939
Display: Next device chain over 30 device.
Used by:
Cause: The next device chain is over 30 devices.
Remedy: Edit the program using the editor to ensure that the next device chain returns to the original
device within 30 devices.
------------------------------
Code: 2100793A
Display: Not found next device.
Used by:
Cause: There is no next device.
Remedy: Edit the program using the editor to ensure that the next device chain returns to the original
device.
------------------------------
Code: 2100793B
Display: Station over.
Used by:
Cause: Because of a "station over" condition the feeders cannot be assigned.
Remedy: Reduce the number of feeders in the program.
------------------------------
Code: 2100793C
Display: Not get Occupancy data.
Used by:
Cause: The machine type table occupancy data cannot be obtained.
Remedy: Re-install machine type table.CP6.
------------------------------
Code: 2100793D
Display: Not get Slot info data.
Used by:
Cause: The machine type table slot information data could not be obtained.
Remedy: Re-install machine type table.CP6.
第 1981 页
------------------------------
Code: 2100793E
Display: Parts height regulation over.
Used by:
Cause: The part height exceeds the maximum value (6 mm).
Remedy: Edit the Part data to ensure that the part height does not exceed the maximum value.
------------------------------
Code: 2100793F
Display: Different cartridge name in Input file and Fix apoint file.
Used by:
Cause: An error occurred when assigning fixed feeders.
Remedy: Edit to ensure that the feeder names in the program and the fixed file are the same.
------------------------------
Code: 21007940
Display: Input file name is too long.
Used by:
Cause: The input file name is too long.
Remedy: The input file name should be within 23 characters.
------------------------------
Code: 21007941
Display: Output file name is too long.
Used by:
Cause: The output file name is too long.
Remedy: The output file name should be within 23 characters, including (.o) when the file name is
abbreviated.
------------------------------
Code: 21007942
Display: PST file name is too long.
Used by:
Cause: The permanent set table (PST) file name is too long. The PST file name should be within 23
characters.
Remedy: Set the permanent set table file name to 23 characters or less.
------------------------------
Code: 21007943
Display: Base program file name is too long.
Used by:
Cause: The base program file name is too long.
Remedy: The base program file name should be within 23 characters.
------------------------------
Code: 21007944
Display: Illegal format at MTT file.
Used by:
Cause: The machine type table (MTT) file format is unsuitable.
Remedy: Re-install MTT.CP6.
------------------------------
Code: 21007945
Display: Make not mount sequence.
Used by:
Cause: An error occurred when mounting sequences were being prepared for the output program.
Remedy: Reboot the MCS.
------------------------------
第 1982 页
Code: 21007946
Display: No entry Machine name.
Used by:
Cause: The machine name is not registered in Part data.
Remedy: Using the editor input the machine name in Part data.
------------------------------
Code: 21007947
Display: Illegal format at pairing data file.
Used by:
Cause: The pairing data file format is unsuitable.
Remedy: Re-install the pairing data file.
------------------------------
Code: 21007948
Display: Not get queue position.
Used by:
Cause: The queue position cannot be obtained.
Remedy: Reboot the MCS.
------------------------------
Code: 21007949
Display: Sequence data axis over range.
Used by:
Cause: The sequence coordinates exceed the board size.
Remedy: Edit the input program to ensure that the sequence data coordinates (X, Y) do not exceed the
board size.
------------------------------
Code: 2100794A
Display: Cam table file open error.
Used by:
Cause: The cam table file cannot be opened.
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794B
Display: Cam table file read error.
Used by:
Cause: The cam table file cannot be read.
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794C
Display: Tllegal format at Cam table file.
Used by:
Cause: The cam table file format is unsuitable
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794D
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100794E
Display: "There is insufficient space for a feeder in PT file"