FUJI错误代码查询 - 第207页

Remedy: Check that the machine has finished changing programs and then input the command. ------------------------------ Code: 1107BF43 Display: Used by: Cause: Program is ineffective. Remedy: None. ---------------------…

100%1 / 5282
Display:
Used by:
Cause: The pallet is being changed (PCM/PPS) so the device lock is disabled.
Remedy: The device lock cannot be used while the pallet is being changed.
------------------------------
Code: 1107BF10
Display:
Used by:
Cause: While downloading device data, the correct data was not downloaded.
Remedy: Download the device data.
------------------------------
Code: 1107BF11
Display:
Used by:
Cause: Cannot perform device check.
Remedy: None.
------------------------------
Code: 1107BF20
Display:
Used by:
Cause: Invalid parameter value.
Remedy: None.
------------------------------
Code: 1107BF30
Display:
Used by:
Cause: The pickup point cannot change in automatic operation.
Remedy: To change the pickup point, interrupt automatic operation.
------------------------------
Code: 1107BF31
Display:
Used by:
Cause: Program cannot be changed.
Remedy: None.
------------------------------
Code: 1107BF40
Display:
Used by:
Cause: With the Handy Terminal in device check, the specified device check was rejected.
Remedy: None.
------------------------------
Code: 1107BF41
Display:
Used by:
Cause: Because the start button was pressed previously, the reset switch is ineffective.
Remedy: None.
------------------------------
Code: 1107BF42
Display:
Used by:
Cause: The command was rejected because the machine is changing programs.
第 206 页
Remedy: Check that the machine has finished changing programs and then input the command.
------------------------------
Code: 1107BF43
Display:
Used by:
Cause: Program is ineffective.
Remedy: None.
------------------------------
Code: 1107BF50
Display:
Used by:
Cause: The command was rejected because the machine was in device check.
Remedy: After device check is finished, re-enter the command.
------------------------------
Code: 1107BF60
Display:
Used by:
Cause: Processing was interrupted because the pallet number is ineffective.
Remedy: Check the pallet numbers in the production program.
------------------------------
Code: 1107BF61
Display:
Used by:
Cause: Processing was interrupted because the pallet number was not specified.
Remedy: Set the pallet number in the production program.
------------------------------
Code: 1107C001
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C001 ID:* E:??
Used by: QP132
Cause: The completion code for the response from the ID reader is not normal.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
??: Finishing code.
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C002
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C002 ID:*
Used by: QP132
Cause: The text that has been received cannot be analyzed.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C003
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C003 ID:*
Used by: QP132
Cause: Transmission time out error has occurred.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
第 207 页
Code: 1107C004
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C004 ID:*
Used by: QP132
Cause: Receiving transmission time out error has occurred.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C005
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C005 ID:*
Used by: QP132
Cause: The allowable number of overwrites for this data carrier has been exceeded.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Change the relevant pallet's data carrier.
------------------------------
Code: 1107C006
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C005 ID:*
Used by: QP132
Cause: The data carrier is not operation correctly.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected. If this
occurs frequently, change the relevant pallet's data carrier.
------------------------------
Code: 1107D001
Display: Association error!
Used by: NP2,QP3
Cause: Failed to start up the association process.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D002
Display: Association error!
Used by: NP2,QP3
Cause: Failed to acquire association data.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D003
Display: DxShell call error!
Used by: NP2,QP3
Cause: An error occurred in the communication between the machine and the parts supply unit.
Remedy: Check if the parts supply unit and the feeders are correctly attached to the machine and restart
the machine.
------------------------------
Code: 1107D004
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Auto-start instruction error!
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.