------------------------------ Code: 2100FA0F Display: '+' option not found Used by: Cause: The '+' option was not found at start-up. Remedy: Correct the input command if this error occurred due to a …
Used by:
Cause: The print file could not be created.
Remedy: Check the RAM for previously created files and for remaining memory. Re-boot MCS.
------------------------------
Code: 2100FA07
Display: change console path error
Used by:
Cause: The terminal path could not be selected during start-up.
Remedy: Check the RAM for previously created files and for remaining memory. Re-boot MCS.
------------------------------
Code: 2100FA08
Display: CRT event link error
Used by:
Cause: The terminal event could not be linked.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100FA09
Display: can't load proper file on memory
Used by:
Cause: The specified file cannot be loaded into memory.
Remedy: Reboot MCS or re-install the system.
------------------------------
Code: 2100FA0A
Display: can't load file descriptor on memory
Used by:
Cause: The file descriptor could not be loaded into memory.
Remedy: Re-boot MCS. If the error recurs, re-install the system.
------------------------------
Code: 2100FA0B
Display: this file is not proper
Used by:
Cause: The specified file is not a Proper data file.
Remedy: Specify the correct file.
------------------------------
Code: 2100FA0C
Display: can't open Lp pipe
Used by:
Cause: The Lp pipe could not be opened.
Remedy: Re-boot MCS.
------------------------------
Code: 2100FA0D
Display: check flag rewrite error
Used by:
Cause: The check flag could not be re-written.
Remedy: Check that the file overwrite protector is not set to prevent overwriting.
------------------------------
Code: 2100FA0E
Display: Proper data NO. %d over range
Used by:
Cause: The **** Proper data item is out of range.
Remedy: Reset the item in question so that it is no longer out of range.
第 2110 页
------------------------------
Code: 2100FA0F
Display: '+' option not found
Used by:
Cause: The '+' option was not found at start-up.
Remedy: Correct the input command if this error occurred due to a direct command.
------------------------------
Code: 2100FA10
Display: Proper for this M/C type is not supported
Used by:
Cause: The specified machine type is not supported.
Remedy: Specify the correct machine type.
------------------------------
Code: 2100FA11
Display: check flag read error
Used by:
Cause: The check flag data could not be read.
Remedy: Use the editor to check that the file is correct.
------------------------------
Code: 2100FA12
Display: Default value is used if no data is entered
Used by:
Cause: The program structure and descriptor structure are different.
Remedy: This is a warning. Correct and save the file using the editor.
------------------------------
Code: 2100FE00
Display: can't read strings file
Used by:
Cause: The string file (Ntchk_str.E) cannot be loaded into memory.
Remedy: Restart MCS or reinstall the system.
------------------------------
Code: 2100FE01
Display: not found '+' opition
Used by:
Cause: The '+' option was not found during startup.
Remedy: If this occurred during startup by direct command, check that the input command was correct.
------------------------------
Code: 2100FE02
Display: Syntax error - illegal '+' option
Used by:
Cause: The '+' option was not found during startup.
Remedy: If this occurred during startup by direct command, check that the input command was correct.
------------------------------
Code: 2100FE03
Display: Syntax error - not found check file
Used by:
Cause: The check object file has not been specified.
Remedy: Specify the filename.
------------------------------
Code: 2100FE04
Display: not found check file on disk
第 2111 页
Used by:
Cause: The specified filename does not exist.
Remedy: Respecify the filename.
------------------------------
Code: 2100FE05
Display: change console path error
Used by:
Cause: During startup, the specified terminal path could not switch to standard input/output.
Remedy: Reexecute the command. If it still does not work, restart MCS.
------------------------------
Code: 2100FE06
Display: CRT event link error
Used by:
Cause: The terminal event could not link.
Remedy: Reexecute the command. If it still does not work, restart MCS.
------------------------------
Code: 2100FE07
Display: can't load NAT file on memory
Used by:
Cause: The specified file could not be loaded into memory.
Remedy: Reexecute the command. If it still does not work, restart MCS.
------------------------------
Code: 2100FE08
Display: can't load file descriptor on memory
Used by:
Cause: The file descriptor cannot be loaded into memory.
Remedy: Reexecute the command. If it still does not work, restart MCS.
------------------------------
Code: 2100FE09
Display: This NAT M/C type is not supported
Used by:
Cause: The specified NAT machine type is not supported.
Remedy: Check the input machine type.
------------------------------
Code: 2100FE0A
Display: this check file is not a NAT
Used by:
Cause: The specified file is not a NAT file.
Remedy: Check that the file overwrite protect is not on.
------------------------------
Code: 2100FE0B
Display: check flag rewrite error
Used by:
Cause: Header data's header check flag could not be written.
Remedy: Check that the file overwrite protect is not on.
------------------------------
Code: 2100FE0C
Display: No.%d :data over range
Used by:
Cause: No. *** in the NAT file is out of range.
Remedy: Check and fix that item.