FUJI错误代码查询 - 第2130页
Code: 2300E11C Display: The main and sub marks are too close together. Used by: Cause: Unable to correct placement because the main and sub marks are too close together. Remedy: Revise the mark settings or to separate th…
------------------------------
Code: 2300E116
Display: The mark name is not specified.
Used by:
Cause: The mark name field in the mark sequence is blank.
Remedy: Specify the mark name to match the existing mark data.
------------------------------
Code: 2300E117
Display: The mark name is not specified. The No. 1 mark from the mark edit screen is being used.
Used by:
Cause: A mark name has not been specified in the sequence editor screen. The No. 1, type F mark from
the mark editor screen is being used.
Remedy: If there is a problem with the mark being used, then specify a different mark name in the
sequence edit screen.
------------------------------
Code: 2300E118
Display: The global skip mark sequence must be positioned earlier in the program than the board skip
mark sequence.
Used by:
Cause: The global skip mark sequence must be positioned earlier in the program than the board skip
mark sequence.
Remedy: Input the global skip mark sequence at an earlier sequence no. than the board skip mark
sequence.
------------------------------
Code: 2300E119
Display: When referencing fiducial marks for global / board skip mark sequences, the board no. for the
fiducial mark sequence must be 0.
Used by:
Cause: When referencing fiducial marks for global / board skip mark sequences, the board no. for the
fiducial mark sequence must be 0.
Remedy: Set the board no. for a fiducial mark sequence to 0 when referencing fiducial marks for global /
board skip mark sequences.
------------------------------
Code: 2300E11A
Display: The fiducial mark sequence must be positioned earlier in the program than the global / board
skip mark sequence.
Used by:
Cause: The fiducial mark sequence must be positioned earlier in the program than the global / board
skip mark sequence.
Remedy: Input the fiducial mark sequence at an earlier sequence no. than the global / board skip mark
sequence.
------------------------------
Code: 2300E11B
Display: A board skip mark sequence for a particular board no. must be positioned earlier in the program
than any placement sequences for that board.
Used by:
Cause: A board skip mark sequence for a particular board no. must be positioned earlier in the program
than any placement sequences for that board.
Remedy: Input the board skip mark sequence for a particular board no. at an earlier sequence no. than
any placement sequences for that board.
------------------------------
第 2129 页
Code: 2300E11C
Display: The main and sub marks are too close together.
Used by:
Cause: Unable to correct placement because the main and sub marks are too close together.
Remedy: Revise the mark settings or to separate the main and sub marks by at least 5 mm.
------------------------------
Code: 2300E11D
Display: Another group skip mark sequence has the same mark number.
Used by:
Cause: Another group skip mark sequence has the same mark number.
Remedy: Change the mark number.
------------------------------
Code: 2300E11E
Display: There is a group skip mark sequence after a board skip mark sequence.
Used by:
Cause: The insertion order is incorrect.There is a group skip mark sequence after a board skip mark
sequence.
Remedy: Change the insert order so that group skip mark sequences are before board skip mark
sequences.
------------------------------
Code: 2300E11F
Display: There is a global skip mark sequence after a group skip or board skip mark sequence.
Used by:
Cause: The insertion order is incorrect.There is a global skip mark sequence after a group skip or board
skip mark sequence.
Remedy: Change the insert order so that global skip sequences are before group skip mark sequences and
board skip mark sequences.
------------------------------
Code: 2300E120
Display: To reference a fiducial mark,a fiducial mark whose board number 0 is required.
Used by:
Cause: When referencing a fiducial mark for a global skip mark,group skip mark,or board skip mark,a
fiducial mark whose board number is 0 is required.
Remedy: Create a fiducial mark sequence whose board number is 0.
------------------------------
Code: 2300E121
Display: The reference fiducial mark is after the current sequence.
Used by:
Cause: The insertion order is incorrect.The reference fiducial mark is after the current sequence.
Remedy: Change the insert order so that the reference fiducial mark is before the indicated sequence.
------------------------------
Code: 2300E201
Display: The Program polarity item's [No] setting is not supported.
Used by:
Cause: XP-series machines do not support Program Polarity's "No" setting.q宝xcept for program data
transmitted from MCS/2q搽Remedy: Set the Program Polarity setting to "Yes".
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E202
Display: The Program Polarity setting [No] in the production program which was transmitted from the
MCS/2 to the XP-141E is not supported.
第 2130 页
Used by:
Cause: MCS/2 programs used on XP-141E with the Program Polarity setting set to "No" cannot be used
on other machine types.
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E203
Display: The Program Polarity setting [No] in the production program which was transmitted from the
MCS/2 to the XP-241E/XP-341E is not supported.
Used by:
Cause: MCS/2 programs used on XP-241E and XP-341E with the Program Polarity setting set to "No"
cannot be used on other machine types.
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E301
Display: Part number has not been specified.
Used by:
Cause: No part number has been set.
Remedy: Either specify a part number or delete the data.
------------------------------
Code: 2300E302
Display: Part data cannot be found.
Used by:
Cause: Data corresponding to the part number does not exist.
Remedy: Create the specified part number data, or specify an existing part number.
------------------------------
Code: 2300E303
Display: Unset slots are included in the slot loop.
Used by:
Cause: A vacant slot number (no setting data) is set as the "next slot" number.
Remedy: Specify a slot number with a same part number.
------------------------------
Code: 2300E304
Display: The part number does not match that of the Alt. Feeder.
Used by:
Cause: A slot number with a different part number setting has been specified as the "next slot".
Remedy: Specify a slot number with a same part number setting for use as the "next slot".
------------------------------
Code: 2300E305
Display: The Alt. Feeder number must be set to a separate feeder.
Used by:
Cause: The slot number and next slot number are identical.
Remedy: Specify a "next slot" number which is different from the slot number.
------------------------------
Code: 2300E306
Display: The alternate feeder setting is not a loop.
Used by:
Cause: The next slot number does not have a loop structure.
Remedy: Set the next slot number so that a loop structure is created.
------------------------------
Code: 2300E307
Display: The packaging type specified in part data cannot be used on this stage.