Used by: Cause: A part number with a Packaging Type of "Tray" is set for a Feeder stage number and slot number, or, a part number with a Packaging Type other than "Tray" is set for a Tray stage number…
Used by:
Cause: MCS/2 programs used on XP-141E with the Program Polarity setting set to "No" cannot be used
on other machine types.
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E203
Display: The Program Polarity setting [No] in the production program which was transmitted from the
MCS/2 to the XP-241E/XP-341E is not supported.
Used by:
Cause: MCS/2 programs used on XP-241E and XP-341E with the Program Polarity setting set to "No"
cannot be used on other machine types.
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E301
Display: Part number has not been specified.
Used by:
Cause: No part number has been set.
Remedy: Either specify a part number or delete the data.
------------------------------
Code: 2300E302
Display: Part data cannot be found.
Used by:
Cause: Data corresponding to the part number does not exist.
Remedy: Create the specified part number data, or specify an existing part number.
------------------------------
Code: 2300E303
Display: Unset slots are included in the slot loop.
Used by:
Cause: A vacant slot number (no setting data) is set as the "next slot" number.
Remedy: Specify a slot number with a same part number.
------------------------------
Code: 2300E304
Display: The part number does not match that of the Alt. Feeder.
Used by:
Cause: A slot number with a different part number setting has been specified as the "next slot".
Remedy: Specify a slot number with a same part number setting for use as the "next slot".
------------------------------
Code: 2300E305
Display: The Alt. Feeder number must be set to a separate feeder.
Used by:
Cause: The slot number and next slot number are identical.
Remedy: Specify a "next slot" number which is different from the slot number.
------------------------------
Code: 2300E306
Display: The alternate feeder setting is not a loop.
Used by:
Cause: The next slot number does not have a loop structure.
Remedy: Set the next slot number so that a loop structure is created.
------------------------------
Code: 2300E307
Display: The packaging type specified in part data cannot be used on this stage.
第 2131 页
Used by:
Cause: A part number with a Packaging Type of "Tray" is set for a Feeder stage number and slot number,
or, a part number with a Packaging Type other than "Tray" is set for a Tray stage number and slot
number.
Remedy: For Feeder stage numbers and slot numbers, specify a part number with a Packaging Type other
than "Tray". For Tray stage numbers and slot numbers, specify a part number with Packaging Type of
"Tray".
------------------------------
Code: 2300E401
Display: Fiducial Marks have not been set.
Used by:
Cause: There is no fiducial mark setting in the production program.
Remedy: Specify a fiducial mark setting at the Edit Mark screen.
------------------------------
Code: 2300E402
Display: Board skip marks have not been set.
Used by:
Cause: A board skip mark reading sequence exists, but there is no board skip mark setting.
Remedy: Specify a board skip mark setting at the Edit Mark screen.
------------------------------
Code: 2300E501
Display: The Polarity Setting item's [Not Use] setting is not supported.
Used by:
Cause: XP-series machines do not support Polarity Setting's "Not Use" setting.q宝xcept for program data
transmitted from MCS/2q搽Remedy: Set the Polarity Setting to another setting.
Remedy:
------------------------------
Code: 2300E502
Display: The Polarity Setting setting [Not Use] in the production program which was transmitted from the
MCS/2 to the XP-141E is not supported.
Used by:
Cause: MCS/2 programs used on XP-141E with the Polarity Setting set to "Not Use" cannot be used on
other machine types.
Remedy: Set the Polarity Setting to another setting.
------------------------------
Code: 2300E503
Display: The Polarity Setting setting [Not Use] in the production program which was transmitted from the
MCS/2 to the XP-241E/XP-341E is not supported.
Used by:
Cause: MCS/2 programs used on XP-241E and XP-341E with the Polarity Setting set to "Not Use" cannot
be used on other machine types.
Remedy: Set the Polarity Setting to another setting.
------------------------------
Code: 2300E540
Display: No suitable nozzle exists.
Used by:
Cause: The nozzle data contains neither the nozzle specified by the NozzleName item (in Part Type data),
or a nozzle which satisfies the NozzleSizeMin to NozzleSizeMax range setting.
Remedy: Specify the appropriate nozzle in the nozzle data.
------------------------------
Code: 2300E541
第 2132 页
Display: The mark check position (area)is outside the body.
Used by:
Cause: The mark check position (area)is outside the body.
Remedy: Enter the correct mark check position (area)coordinates.
------------------------------
Code: 2300E542
Display: Mark check area is improper.
Used by:
Cause: Mark check area is improper.
Remedy: Enter the correct mark check area coordinates.
This error occurs when the 'Upper Left X' and 'Lower Right X',or 'Upper Left Y' and 'Lower Right Y'
values are the same.
------------------------------
Code: 2300E543
Display: Mark check area is specified at the body center.
Used by:
Cause: Mark check area is specified at the body center.Unable to check the part supply orientation in the
case that the mark check area is specified at the body center.
Remedy: Check the specified coordinates and the area for mark checking.
------------------------------
Code: 2300E571
Display: ElementData is necessary when a Vision Type other than 10, or 18 is used.
Used by:
Cause: There is no ElementData although a Vision Type other than 10 or 18 is specified.
Remedy: Set the ElementData.
------------------------------
Code: 2300E572
Display: Set a value of 1 or above for [Lead Quantity] if the Vision Type is specified as 20, 100, 124, 130,
or 180.
Used by:
Cause: A "Lead Quantity" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124, 130, or 180 is specified.
Remedy: Specify a suitable "Lead Quantity" setting.
------------------------------
Code: 2300E573
Display: Set a value of 1 or above for [Lead Length] if the Vision Type is specified as 20, 100, 124, or 180.
Used by:
Cause: A "Lead Length" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124, or 180 is specified.
Remedy: Specify a suitable "Lead Length" setting.
------------------------------
Code: 2300E574
Display: Set a value of 1 or above for [Lead Width] if the Vision Type is specified as 20, 100, 124,130 or
180.
Used by:
Cause: A "Lead Width" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124,130 or 180 is specified.
Remedy: Specify a suitable "Lead Width" setting.
------------------------------
Code: 2300E575
Display: Vision Type 20 cannot be used for parts with 6 or more leads.
第 2133 页