FUJI错误代码查询 - 第2134页
Used by: Cause: Vision Type 20 does not allow a "Lead Quantity" setting value of 6 or higher. Remedy: Either change the Vision Type, or change the "Lead Quantity" setting to a value of 5 or less. ----…
Display: The mark check position (area)is outside the body.
Used by:
Cause: The mark check position (area)is outside the body.
Remedy: Enter the correct mark check position (area)coordinates.
------------------------------
Code: 2300E542
Display: Mark check area is improper.
Used by:
Cause: Mark check area is improper.
Remedy: Enter the correct mark check area coordinates.
This error occurs when the 'Upper Left X' and 'Lower Right X',or 'Upper Left Y' and 'Lower Right Y'
values are the same.
------------------------------
Code: 2300E543
Display: Mark check area is specified at the body center.
Used by:
Cause: Mark check area is specified at the body center.Unable to check the part supply orientation in the
case that the mark check area is specified at the body center.
Remedy: Check the specified coordinates and the area for mark checking.
------------------------------
Code: 2300E571
Display: ElementData is necessary when a Vision Type other than 10, or 18 is used.
Used by:
Cause: There is no ElementData although a Vision Type other than 10 or 18 is specified.
Remedy: Set the ElementData.
------------------------------
Code: 2300E572
Display: Set a value of 1 or above for [Lead Quantity] if the Vision Type is specified as 20, 100, 124, 130,
or 180.
Used by:
Cause: A "Lead Quantity" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124, 130, or 180 is specified.
Remedy: Specify a suitable "Lead Quantity" setting.
------------------------------
Code: 2300E573
Display: Set a value of 1 or above for [Lead Length] if the Vision Type is specified as 20, 100, 124, or 180.
Used by:
Cause: A "Lead Length" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124, or 180 is specified.
Remedy: Specify a suitable "Lead Length" setting.
------------------------------
Code: 2300E574
Display: Set a value of 1 or above for [Lead Width] if the Vision Type is specified as 20, 100, 124,130 or
180.
Used by:
Cause: A "Lead Width" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124,130 or 180 is specified.
Remedy: Specify a suitable "Lead Width" setting.
------------------------------
Code: 2300E575
Display: Vision Type 20 cannot be used for parts with 6 or more leads.
第 2133 页
Used by:
Cause: Vision Type 20 does not allow a "Lead Quantity" setting value of 6 or higher.
Remedy: Either change the Vision Type, or change the "Lead Quantity" setting to a value of 5 or less.
------------------------------
Code: 2300E576
Display: Lead Width is not defined.
Used by:
Cause: A "Lead Width" setting of "0" existed where the Result was other than 128 for the "Element" item
of a Vision Type 230 or 231 part.
Remedy: Specify "Lead Width" settings at lines where the Result is other than 128 for the "Element" item
of a Vision Type 230 or 231 part.
------------------------------
Code: 2300E577
Display: Lead Quantity is not defined.
Used by:
Cause: A "Lead Quantity" setting of "0" existed where the Result was other than 128 for the "Element"
item of a Vision Type 230 or 231 part.
Remedy: Specify "Lead Quantity" settings at lines where the Result is other than 128 for the "Element"
item of a Vision Type 230 or 231 part.
------------------------------
Code: 2300E578
Display: 128 cannot be set at the first line of Result.
Used by:
Cause: A setting of "128" exists at the first Result line for the Element item of a Vision Type 230 or 231
part.
Remedy: Specify a setting other "128" at the first Result line for the Element item of a Vision Type 230 or
231 part.
------------------------------
Code: 2300E579
Display: Result is set to 128 for 2 consecutive element lines.
Used by:
Cause: A setting of "128" exists at two consecutive Result lines for the Element item of a Vision Type 230
or 231 part.
Remedy: Do not specify a "128" setting at two consecutive Result lines for the Element item of a Vision
Type 230 or 231 part.
------------------------------
Code: 2300E57A
Display: When using Vision Type 230 or 231, set the P Pattern to 1 or 2.
Used by:
Cause: For Vision Types 230 and 231, vision processing is only possible when the "P Pattern" is set to 1
or 2.
Remedy: For Vision Types 230 and 231, set the "P Pattern" to 1 or 2.
------------------------------
Code: 2300E57B
Display: 2 Element lines are required for Vision Type 20.
Used by:
Cause: For Vision Type 20, vision processing is only possible when the "Element" setting occupies 2 or
more lines.
Remedy: Specify 2 lines for the "Element" setting. If the Element sides are not facing each other, change
the Vision Type.
------------------------------
第 2134 页
Code: 2300E57C
Display: When using Vision Type 20, the first and second Element side settings must be specified as either
0 and 2, or, 1 and 3.
Used by:
Cause: Vision Type 20 cannot be used for parts where the "Element" first and second line sides are not
facing each other (not [0-2] or [1-3]).
Remedy: For Vision Type 20, set so that the "Element" first and second line sides are facing each other
([0-2] or [1-3]).
------------------------------
Code: 2300E57D
Display: Vision Type 230, 231 cannot be used to process BGAs with less than 12 balls.
Used by:
Cause: Vision Type 230 and 231 vision processing is not possible for BGA parts with fewer than 12 balls.
Remedy: Set the Element's "Lead Quantity" so that the total number of balls is 12 or more. If the total
number of balls is fewer than 12, use Vision Type 18.
------------------------------
Code: 2300E57E
Display: Specify Lead Pitch if the Lead Quantity is 2 or greater.
Used by:
Cause: A "Lead Pitch" setting of "0" existed when the "Lead Quantity" setting was 2 or more.
Remedy: When the "Lead Quantity" setting is 2 or more, specify a "Lead Pitch" setting.
------------------------------
Code: 2300E57F
Display: When using Vision Type 10, the Body Length (X) should be the same size or larger than the Body
Width (Y).
Used by:
Cause: When using Vision Type 10, the "Body Length (Y) dimension exceeded the "Body Length (X)"
dimension.
Remedy: When using Vision Type 10, specify a "Body Length (X) dimension which is larger than the "Body
Length (Y)" dimension.
------------------------------
Code: 2300E580
Display: When using Vision Type 100 or 130, the Lead Quantity must be 5 or greater for the first element.
Used by:
Cause: When using Vision Type 100 or 130, the "Element's" first line "Lead Quantity" was less than 5.
Remedy: When using Vision Types 100 and 130, specify the "Element's" first line "Lead Quantity" as 5 or
more.
------------------------------
Code: 2300E581
Display: The value set for Stand Off height is higher than or equal to the Part Height.
Used by:
Cause: The value set for Stand Off height is higher than or equal to the Part Height.
Remedy: Enter a value lower than the Part Height.
------------------------------
Code: 2300E582
Display: Parts using vision type 230 or 231 require at least one element with lead quantity of two or more.
(Excluding the second row of data in the matrix display.)
Used by:
Cause: The element data for parts using vision type 230 or 231 does not have an element with two or
more leads.
Remedy: When using vision type 230 or 231, create at least one element with lead quantity of two or
第 2135 页