Code: 2304001F Display: Contents are not Nozzle Configuration File. Used by: Cause: The field "UNIT", "NZLCONF" does not exist. Remedy: There is a problem with the Nozzle Config. file. Normally, the N…

100%1 / 5282
Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close
to the feeder to the left.
Used by:
Cause: In the program's feeder setup, a feeder wide enough to interfere with the adjacent feeder on the
left side.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 2304001A
Display: Are you finished?
Used by:
Cause: The confirmation dialog displays at each time of completion.
Remedy: Select [Yes] to finish. Select [No] to continue.
------------------------------
Code: 2304001B
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, or optimization process has completed, but the optimized
program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
When attempting to open the program file, select [No] to abandon the optimized program, and display the
dialog for selecting a new program file to be optimized.
When optimization process has completed, select [No] to exit without saving the optimized program.
------------------------------
Code: 2304001C
Display: No nozzle is registered.
Used by:
Cause: No valid nozzle match could be made between the Nozzle Config. file's NCFTYPE and the Nozzle
Spec. file's NSPNAME.
Remedy: There is a problem with either or both files. Normally, the Nozzle Config. and Nozzle Spec. files
in the MCS-X default directory are read automatically. Check that both files contain correct data. When
starting up the optimizer, in cases where prompted to specify a file because the default file cannot be
found, check the file contents and correct if necessary.
------------------------------
Code: 2304001D
Display: Nozzle Configuration File "Fujinzl.cfg" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 2304001E
Display: The contents of Nozzle Configuration File are empty.
Used by:
Cause: The Nozzle Config. file is empty.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
第 2142 页
Code: 2304001F
Display: Contents are not Nozzle Configuration File.
Used by:
Cause: The field "UNIT", "NZLCONF" does not exist.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040020
Display: Cannot read the file.
Used by:
Cause: An error occurred while reading the Nozzle Config. file.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040021
Display: There are no data for "XP-141" in the file.
Used by:
Cause: XP-141 Nozzle Config. information (XP141 specified in NZLCONF/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040024
Display: The nozzle items "NCFNAME" or "NCFTYPE" do not exist in the file.
Used by:
Cause: The Nozzle Name and Nozzle Type cannot be obtained because either or both of the fields,
"NCFNAME" and "NCFTYPE" are missing from underneath the ["BLOCK","CONFIG+"] field in the XP-141
Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040025
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
configuration items.
Used by:
Cause: The item count in the field immediately following the ["BLOCK","CONFIG+"] field in the XP-141
Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE) does not match the actual
number of items in the fields below that field.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040026
第 2143 页
Display: No nozzle is registered.
Used by:
Cause: No fields containing data could be found in the second row below the ["BLOCK","CONFIG+"] field
or beyond in the XP-141 Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040027
Display: Nozzle Specification File "Fujinzl.dat" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 23040028
Display: The contents of the file are empty.
Used by:
Cause: The Nozzle Spec. file size is 0 bytes.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040029
Display: Contents are not Nozzle Specifications File.
Used by:
Cause: The field "UNIT", "NZLSPEC" does not exist.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2304002A
Display: Cannot read the file.
Used by:
Cause: An error occurred while reading the Nozzle Spec. file.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2304002B
Display: There are no data for "XP-141" in the file.
Used by:
Cause: XP-141 Nozzle Spec. information (XP141 specified in NZLSPEC/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
第 2144 页