FUJI错误代码查询 - 第2146页
Remedy: There is a problem with the program file. Check that the file contents are correct. ------------------------------ Code: 23040035 Display: The nozzle specified by the program file does not exist in Nozzle Configu…
------------------------------
Code: 2304002E
Display: The nozzle items "NCFNAME", "NCFTYPE" or "NSPNSIZD" do not exist in the file.
Used by:
Cause: The Nozzle Name, Nozzle Type, and Nozzle diameter cannot be obtained because one or more of
the fields, "NSPNAME", "NSPTYPE", and "NSPNSIZD" are missing from underneath the ["BLOCK","SPEC+"]
field in the XP-141 Nozzle Spec. information file (XP141 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2304002F
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
specification items.
Used by:
Cause: The item count in the field immediately following the ["BLOCK","SPEC+"] field in the XP-141
Nozzle Spec. information file (XP141 specified in NZLSPEC/HEADER/TYPE) does not match the actual
number of items in the fields below that field.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040030
Display: No nozzle is registered.
Used by:
Cause: No fields containing data could be found in the second row below the ["BLOCK","SPEC+"] field or
beyond in the XP-141 Nozzle Spec. information file (XP141 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040032
Display: The specified program file cannot be found. Search for a file?
Used by:
Cause: The specified program file name does not exist.
Remedy: Select [Yes] to display the dialog for selecting a program file to be read. Select [Abort] to cancel.
------------------------------
Code: 23040033
Display: The specified program file is not a CCIMF file (.pgo). Search for a file?
Used by:
Cause: The specified program file was not a CCIMF file.
Remedy: Select [Yes] to display the dialog for selecting a program file. Select [Abort] to cancel.
------------------------------
Code: 23040034
Display: The amount of nozzle data does not match with the nozzle data fields.
Used by:
Cause: In the Nozzle folder information file, the "NOZZLE", "XP141+" field and the item count for the
fields following that field do not match.
第 2145 页
Remedy: There is a problem with the program file. Check that the file contents are correct.
------------------------------
Code: 23040035
Display: The nozzle specified by the program file does not exist in Nozzle Configuration File and Nozzle
Specification File. Do you want to continue?
Used by:
Cause: The nozzle specified in the program does not exist in the Nozzle Config. file and Nozzle Spec. file.
Remedy: Select [Yes] to ignore, and continue reading of the program file. Select [Abort] to cancel reading of
the program file.
------------------------------
Code: 23040036
Display: The following program file sequence's stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero,
placement cannot be performed as the slot cannot be determined.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 23040037
Display: The program file feeder setup stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero, feeders
cannot be allotted as the slot cannot be determined.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 23040039
Display: No compatible nozzle exists for this part.
Used by:
Cause: When creating the nozzle arrangement automatically, no nozzle diameter could be found within
the range defined by minimum nozzle diameter and maximum nozzle diameter in the part data.
Remedy: Check the minimum nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMI) and maximum
nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 2304003A
Display: The stage/slot numbers for the following placement sequence in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 2304003B
Display: The stage number value in the following sequence in the program file is out of range.
Used by:
第 2146 页
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 2304003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 50.
------------------------------
Code: 2304003D
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 2, the slot number input range is 1 to 450.
------------------------------
Code: 2304003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 2304003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 23040040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 50.
------------------------------
Code: 23040041
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 2, the slot number input range is 1 to 450.
------------------------------
Code: 23040042
Display: There are more than 12 kinds of Nozzles specified (Too many for the Revolver).
第 2147 页