Code: 2306002F Display: A syntax error occurred because the data field count does not agree with the number of nozzle specification items. Used by: Cause: The item count in the field immediately following the ["BLOC…
or beyond in the XP-341 Nozzle Config. information file (XP341 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23060027
Display: Nozzle Specification File "Fujinzl.dat" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 23060028
Display: The contents of the file are empty.
Used by:
Cause: The Nozzle Spec. file size is 0 bytes.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23060029
Display: Contents are not Nozzle Specifications File.
Used by:
Cause: The field "UNIT", "NZLSPEC" does not exist.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2306002B
Display: There are no data for "XP-341" in the file.
Used by:
Cause: XP-341 Nozzle Spec. information (XP341 specified in NZLSPEC/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2306002E
Display: The nozzle items "NSPNAME", "NSPTYPE" or "NSPNSIZD" do not exist in the file.
Used by:
Cause: The Nozzle Name, Nozzle Type, and Nozzle diameter cannot be obtained because one or more of
the fields, "NSPNAME", "NSPTYPE", and "NSPNSIZD" are missing from underneath the ["BLOCK","SPEC+"]
field in the XP-341 Nozzle Spec. information file (XP341 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
第 2165 页
Code: 2306002F
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
specification items.
Used by:
Cause: The item count in the field immediately following the ["BLOCK","SPEC+"] field in the XP-341
Nozzle Spec. information file (XP341 specified in NZLSPEC/HEADER/TYPE) does not match the actual
number of items in the fields below that field.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23060030
Display: No nozzle is registered.
Used by:
Cause: No fields containing data could be found in the second row below the ["BLOCK","SPEC+"] field or
beyond in the XP-341 Nozzle Spec. information file (XP341 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23060032
Display: The specified program file cannot be found. Search for a file?
Used by:
Cause: The specified program file name does not exist.
Remedy: Select [Yes] to display the dialog for selecting a program file to be read. Select [Abort] to cancel.
------------------------------
Code: 23060033
Display: The specified program file is not a CCIMF file (.pgo). Search for a file?
Used by:
Cause: The specified program file was not a CCIMF file.
Remedy: Select [Yes] to display the dialog for selecting a program file. Select [Abort] to cancel.
------------------------------
Code: 23060034
Display: The amount of nozzle data does not match with the nozzle data fields.
Used by:
Cause: In the Nozzle folder information file, the "NOZZLE", "XP341+" field and the item count for the
fields following that field do not match.
Remedy: There is a problem with the program file. Check that the file contents are correct.
------------------------------
Code: 23060035
Display: The nozzle specified by the program file does not exist in Nozzle Configuration File and Nozzle
Specification File. Do you want to continue?
Used by:
Cause: The nozzle specified in the program does not exist in the Nozzle Config. file and Nozzle Spec. file.
Remedy: Select [Yes] to ignore, and continue reading of the program file. Select [Abort] to cancel reading
of the program file.
------------------------------
Code: 23060036
Display: The following program file sequence's stage and slot No. are set to zero.
第 2166 页
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero,
placement cannot be performed as the slot cannot be determined.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 23060037
Display: The program file feeder setup stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero, feeders
cannot be allotted as the slot cannot be determined.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 23060039
Display: No compatible nozzle diameter exists for this part.
Used by:
Cause: When creating the nozzle arrangement automatically, no Nozzle Diameter could be found within
the range defined by Minimum Nozzle Diameter and Maximum Nozzle Diameter in the part data.
Remedy: Check the Minimum Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-/PENMI) and Maximum
Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 2306003A
Display: The stage/slot numbers for the following placement sequence in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 2306003B
Display: The stage number value in the following sequence in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 2306003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 100. When the stage
number value is 2, the slot number input range is 1 to 400.
------------------------------