FUJI错误代码查询 - 第229页
Used by: NP2,QP3 Cause: Device data and feeder data are not consistent. Remedy: Download an uncorrupted program file and select it using the [Program] command. ------------------------------ Code: 1110010E Display: Produ…
Alternatively, download an uncorrupted program and select it using the [Program] command.
------------------------------
Code: 11100106
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the program file.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100107
Display: Nozzle(s) missing!
Used by: NP2,QP3
Cause: Cannot find the nozzles specified in the program.
Remedy: Insert the required nozzles in the station and use the [Nozzle Settings] command to make the
required changes.
------------------------------
Code: 11100108
Display: Nozzle name consistency error!
Used by: NP2,QP3
Cause: The nozzles specified in the program are missing from the NAT file.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
Alternatively, download an uncorrupted NAT file and restart the machine.
------------------------------
Code: 11100109
Display: Nozzle name consistency error!
Used by: NP2,QP3
Cause: The nozzle station name specified in the program differs from that in memory.
Remedy: Exchange the nozzle station or use the [Update] command to update machine memory.
Note: Production with a different nozzle station is possible as long as the required nozzles are
available.
------------------------------
Code: 1110010A
Display: Nozzle station consistency error!
Used by: NP2,QP3
Cause: The nozzle station specified in the program are missing from the nozzle station file.
Remedy: Download an uncorrupted program file and select it usiAlternatively, download an uncorrupted
nozzle station file and restart the machine.
------------------------------
Code: 1110010B
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Failed to close next device loop.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010C
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: The next device slot exceeds the number available at the specified stage.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010D
Display: Production program data mismatch.
第 228 页
Used by: NP2,QP3
Cause: Device data and feeder data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010E
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Feeder and part data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010F
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Part number data and part shape data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100110
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Part number data and part packaging data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100111
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Sequence and feeder data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100112
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Fiducial marks are missing from the program.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100113
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Block skip marks are missing from the program.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100114
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: The mark sequence being referred to by a mark does not exist.
Either the mark is referring itself or a mark that is read in a later sequence.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100115
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Mark sequences that are referenced by the placing sequences are missing from the program.
第 229 页
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100116
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Pre-allocation sequence order error!
Remedy: Revise the Place Before sequence order and reload the program using the change program
command.
------------------------------
Code: 11100117
Display: Parts camera not installed!
Used by: NP2,QP3
Cause: The camera types displayed in the parameter section are not installed on the machine.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100118
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: A frontlight setting has been specified for a CCD camera.
Remedy: Specify a backlight setting for the CCD camera.
------------------------------
Code: 11100119
Display: MCTYPE error
Used by: NP2,QP3
Cause: The MCTYPE settings in the program are not suitable for this machine.
Remedy: Specify a different production program.
------------------------------
Code: 1110011A
Display: Production program error.
Used by: NP2,QP3
Cause: There is a problem with the program. Refer to the parameters.
Remedy: Specify a different program.
------------------------------
Code: 1110011B
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The board has not stopped at the correct position due to incorrect conveyance, deceleration, or
acceleration speeds, or incorrect distance between the deceleration and arrival sensors.
Remedy: Either reduce the conveyance speed, or increase the speed of acceleration/deceleration.
Alternatively, increase the distance between the deceleration and arrival sensors.
------------------------------
Code: 1110011C
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The board has not stopped at the correct position due to incorrect speed of
acceleration/deceleration (+G160).
Remedy: Reduce the deceleration speed, or increase the acceleration speed.
------------------------------
Code: 1110011D
Display: Production program check alarm
Used by: NP2,QP3
第 230 页