FUJI错误代码查询 - 第231页

Cause: Data exists in production program for side that has no part supply position. Remedy: Execute program change command after downloading correct production program. ------------------------------ Code: 1110011E Displ…

100%1 / 5282
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100116
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Pre-allocation sequence order error!
Remedy: Revise the Place Before sequence order and reload the program using the change program
command.
------------------------------
Code: 11100117
Display: Parts camera not installed!
Used by: NP2,QP3
Cause: The camera types displayed in the parameter section are not installed on the machine.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100118
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: A frontlight setting has been specified for a CCD camera.
Remedy: Specify a backlight setting for the CCD camera.
------------------------------
Code: 11100119
Display: MCTYPE error
Used by: NP2,QP3
Cause: The MCTYPE settings in the program are not suitable for this machine.
Remedy: Specify a different production program.
------------------------------
Code: 1110011A
Display: Production program error.
Used by: NP2,QP3
Cause: There is a problem with the program. Refer to the parameters.
Remedy: Specify a different program.
------------------------------
Code: 1110011B
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The board has not stopped at the correct position due to incorrect conveyance, deceleration, or
acceleration speeds, or incorrect distance between the deceleration and arrival sensors.
Remedy: Either reduce the conveyance speed, or increase the speed of acceleration/deceleration.
Alternatively, increase the distance between the deceleration and arrival sensors.
------------------------------
Code: 1110011C
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The board has not stopped at the correct position due to incorrect speed of
acceleration/deceleration (+G160).
Remedy: Reduce the deceleration speed, or increase the acceleration speed.
------------------------------
Code: 1110011D
Display: Production program check alarm
Used by: NP2,QP3
第 230 页
Cause: Data exists in production program for side that has no part supply position.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 1110011E
Display: Production program check alarm
Used by: NP2,QP3
Cause: Specified cavity number exceeds the tray dimensions.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 1110011F
Display: Production program check alarm
Used by: NP2,QP3
Cause: Invalid data for pin check mode exists.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100120
Display: Production program check alarm
Used by: NP2,QP3
Cause: Light setting for pin check mode is incorrect.
If "Cut" is specified : Do not use frontlight.
If "Mark" or "Bump" is specified : Do not use backlight.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100121
Display: Simultaneous mark reading error
Used by: NP-2, QP-3
Cause: Simultaneous reading of unsuitable marks was specified in the production program. Marks
should be read one at a time.
Remedy: Change the settings in the program. Mark sequences within the parameter area cannot be read
simultaneously.
------------------------------
Code: 11100122
Display: Production program check alarm
Used by: NP2,QP3
Cause: Tape feed pitch is not set to (a) motor feeder.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100124
Display: Production program check alarm
Used by: QP3
Cause: Although the CCGA Mark Check item has been set to YES(1), the Pin Check Mode has not been
set to MARK(5) or BUMP(6).
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100125
Display: Production program check alarm
Used by: QP3
Cause: The feeder type has not been set to "Tray" for the STU.
Remedy: Only trays can be supplied to STUs. When using an STU, the feeder type must be set to "Tray".
When not using an STU, specify an appropriate feeder type.
------------------------------
第 231 页
Code: 11100126
Display: Production program check alarm
Used by: QP3
Cause: An STU9 has been specified for SIDE 1.
Remedy: An STU9 cannot be used on SIDE 1, Specify an appropriate device type.
------------------------------
Code: 11100127
Display: Production program data mismatch
Machine type: all PCC machines
Used by:
Cause: A Panel ID/Board ID exists in the sequence, but the Panel ID/Board ID data does not exist.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110012A
Display: Production program check error
Machine type: QP3
Used by:
Cause: Parts with the package type set to "Tray" have been allocated to a MFU/PFU but no STU has been
assigned.
Remedy: Assign an STU for Feeder Name (F4G: Feeder Spec Name) or, when the STU is not being used
with the MFU/PFU, do not assign a tray for the package type.
------------------------------
Code: 1110012B
Display: Production program check error
Machine type: QP3
Used by:
Cause: Insertion control has been specified in the production program, however this function is not used
on this machine.
Remedy: Upgrade the servo control software to a version supporting SERCOS interface torque control in
order to use the insertion control function. Specify normal surface placement in the program if not using
insertion control.
------------------------------
Code: 11100130
Display: Production program data mismatch
Machine type: QP3
Used by:
Cause: There is an error in the mark specification that prevents placement offset based on 2 marks.
Placement offset cannot be calculated because the main mark and sub mark are in the same position.
Remedy: Specify fiducial marks with different positions for the main mark and sub mark.
------------------------------
Code: 11100131
Display: Production program error.
Used by: QP3
Cause: A placing sequence coordinate is out of range.
Remedy: Set the Y-direction placing coordinate within the maximum board width.
The final Y placing coordinate is calculated at [Location Y] of sequence data by adding [Machine
origin and program origin offset Y (Ya)] in the program header and [Place-Offset Y] in part data.
If the [Location Y] setting is correct, check to see if an incorrect offset has been set.
------------------------------
Code: 11100132
Display: Production program data mismatch.