Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file error occurred for the machine calibration data file. All machine data items have
been reset to their default values.
Remedy: Remeasure calibration data, or use the [Data Editor] command to edit the required items, and
use the [System Backup] command to save the changes.
Alternatively, download an uncorrupted calibration data file and load it using the [Restore System]
command.
------------------------------
Code: 11100207
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range.
Remedy: Remeasure calibration data, or use the [Data Editor] command to edit the required items.
Alternatively, download an uncorrupted calibration data file and load it using the [Restore System]
command.
------------------------------
Code: 11100208
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the machine calibration data file.
Remedy: Remeasure calibration data, or use the [Data Editor] command to edit the required items, and
use the [System Backup] command to save the changes.
------------------------------
Code: 11100209
Display: MCTYPE error
Used by: NP2,QP3
Cause: The MCTYPE settings in calibration data are not suitable for this machine. All values returned to
default settings.
Remedy: Use the [Calibration] commands to reset calibration data.
------------------------------
Code: 1110020A
Display: Insufficient data!
Used by: NP2,QP3
Cause: The displayed parameter item does not exist in the Proper data file.
Remedy: Use the file management command to restore the Proper data file.
------------------------------
Code: 1110020B
Display: 读取生产程序错误
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 不能读取生产程序。
Remedy: 请读取其他生产程序。
------------------------------
Code: 1110020C
Display: 没有从MCS/2处来的反馈。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 没有从MCS/2处来的反馈。
Remedy: 请确认MCS/2-机器之间的连接以及MCS/2的电源是否打开。
------------------------------
Code: 1110020D
Display: 接收到从MCS/2处来的没有对应的指令。
第 234 页
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 接收到从MCS/2处来的没有对应的指令。
Remedy: 取得跟踪数据后,请送至敝社。
------------------------------
Code: 1110020E
Display: 接收程序失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 传送了其他机型的生产程序。
Remedy: 请确认生产程序的机型以及在生产程序上是否设定了在机器上不存在的Slot No.。
------------------------------
Code: 11100301
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the machine configuration data file.
Remedy: Select the [Configuration] command to edit the required items and use the [System Backup]
command to save the changes.
Alternatively, download an uncorrupted configuration data file and load it using the [Restore
System] command.
------------------------------
Code: 11100302
Display: File save error!
Used by: NP2,QP3
Cause: Failed to write the machine configuration data file to the hard disk.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100303
Display: File creation error!
Used by: NP2,QP3
Cause: Failed to create a new machine calibration data file.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100304
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the machine configuration data file is too old. All data items have been reset to
their default values.
Remedy: Select the [Configuration] command to edit the required items and use the [System Backup]
command to save the changes.
This will cause the revision file to be renewed automatically.
------------------------------
Code: 11100305
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the machine configuration data file is too new. All data items have been reset to
their default values.
Remedy: Upgrade the system software.
Alternatively, download an old revision configuration data file and load it using the [Restore System]
command.
------------------------------
Code: 11100306
Display: CCIMF file format error!
第 235 页
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the machine configuration data file. All machine data
items have been reset to their default values.
Remedy: Select the [Configuration] command to edit the required items and use the [System Backup]
command to save the changes.
Alternatively, download an uncorrupted configuration data file and load it using the [Restore
System] command.
------------------------------
Code: 11100307
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range.
Remedy: Select the [Configuration] command to edit the required items.
Alternatively, download an uncorrupted configuration data file and load it using the [Restore
System] command.
------------------------------
Code: 11100308
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the machine configuration data
file.
Remedy: Select the [Configuration] command to edit the required items and use the [System Backup]
command to save the changes.
------------------------------
Code: 11100309
Display: MCTYPE error
Used by: NP2,QP3
Cause: The MCTYPE settings in calibration data are not suitable for this machine. All values returned to
default settings.
Remedy: Use the [Calibration] commands to reset calibration data. Alternatively, use the [Restore System]
command at the [Data Manager] screen to restore calibration data.
------------------------------
Code: 1110030A
Display: Insufficient data!
Used by: NP2,QP3
Cause: The displayed parameter item does not exist in the machine function settings file.
Remedy: Use the management command to restore the machine function settings file.
------------------------------
Code: 1110030B
Display: The parts camera type is incorrect
Used by: QP3
Cause: The parts camera type specified in the machine settings cannot be used on this machine.
Remedy: Check the part camera type specified in the machine settings.
------------------------------
Code: 11100401
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the machine status file. All machine status settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)