FUJI错误代码查询 - 第492页

the table.Move the table to the loading position and ensure that the upper and lower sensors work properly by performing the lifter up/down command and performing an I/O check. ------------------------------ Code: 120501…

100%1 / 5282
Display: "Pallet clamp error: IN stn"
Used by: CP5
Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the IN station.
Remedy: If there is a pallet in the IN station, check the carrier pallet check sensor. If there is no pallet,
enter a command to set the IN station ID to 0.
------------------------------
Code: 12050105
Display: "Pallet clamp error: WRK stn"
Used by: CP5
Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the WRK station.
Remedy: If there is a pallet in the WRK station, check the carrier pallet check sensor. If there is no pallet,
enter a command to set the WRK station ID to 0.
------------------------------
Code: 12050106
Display: "Pallet clamp error: OUT stn"
Used by: CP5
Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the OUT station.
Remedy: If there is a pallet in the OUT station, check the carrier pallet check sensor. If there is no pallet,
enter a command to set the OUT station ID to 0.
------------------------------
Code: 12050107
Display: "Pallet clamp error: IN stn"
Used by: CP5
Cause: The IN station pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the IN station.
Remedy: Check the IN station pallet check sensor.
------------------------------
Code: 12050108
Display: "Pallet clamp error: OUT stn"
Used by: CP5
Cause: The OUT station pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the OUT station.
Remedy: Check the OUT station pallet check sensor.
------------------------------
Code: 12050109
Display: "1st pickup check sensor alarm"
Used by: CP5
Cause: The 1st robot component check sensor is stuck off.
Remedy: The 1st robot component check sensor is a reflection sensor. The will not turn on because the
sensor beam is improperly aligned.Adjust the sensor.
------------------------------
Code: 1205010A
Display: Lifter Not at lower limit (CP6/6M).
Used by: CP6
Cause: Before the XY table was moved in the automatic operation mode, the input from the table's lower
position 2 sensor (X032: TABLE DNCHK2) was checked, and found to be OFF. Therefore, to avoid a
collision, an emergency stop was made.
Remedy: Ensure that the sensor at table lower position 2 is working properly. Check for foreign objects on
第 491 页
the table.Move the table to the loading position and ensure that the upper and lower sensors work
properly by performing the lifter up/down command and performing an I/O check.
------------------------------
Code: 1205010B
Display: "Interlock: camera" (GP-6)
Used by: GP551,GP6
Cause: The Z-axis and X-axis are in the interference zone, or are interfering with each other. This error
may also be caused by a sensor error.
Remedy: If the Z-axis and Y-axis are interfering with each other, manually move the X-axis until the X-
axis escape position check sensor (X03D: X ESC POS CHK) is tripped. If they are in the interference zone,
or if there is no interference, check the X-axis escape position check sensor (X03D: X ESC POS CHK) and
the Z-axis camera interference prevention check sensor (X03C: Z ESC POS CHK).
------------------------------
Code: 1205010C
Display: Interlock Sqg/Cleaner Head
Used by:
Cause: This error occurs when both the upper cleaning head and the squeegee are in the lowered
position.
Remedy: Raise the cleaning head or the squeegee holder. Alternatively, check the following sensors:
(X070: (F) SQG HLDR UP, X078: R SQG HLDR UP) or (X07C: TP CLR OPN CHK, X05A: LW CLR OPN CHK).
------------------------------
Code: 1205010E
Display: Sqg Head Unlock
Used by: GP551,GP6
Cause: The squeegee head has been opened.
Remedy: Close and lock the squeegee head.
------------------------------
Code: 1205010F
Display: "Parking Position Error"
Used by: GP551,GP6
Cause: When a parking command is executed, the squeegee head is down after the S-axis has moved to
the position specified in the Proper data and the squeegee parking position check sensor (X03F) has
turned on. This error occurs when the squeegee parking position check sensor remains off after the S-axis
has moved.
Remedy: Check the position detected by the parking position check sensor and the position specified by
the "Parking Position S" parameter in the Proper data.These should be adjusted so that the sensor turns
on when the S-axis arrives at the parking position, and the squeegee head comes to rest on the screen
support when it is down.
------------------------------
Code: 12050110
Display: Sqg Head Position Error
Used by: GP551
Cause: The squeegee head is not in the locked position.
Remedy: Ensure that the squeegee head is in the locked position.
------------------------------
Code: 12050111
Display: Top Cleaner Position Error
Used by: GP551
Cause: The top cleaner swing bar is not in the locked position.
Remedy: Move the top cleaner swing bar to the locked position.
------------------------------
第 492 页
Code: 12050112
Display: Btm Cleaner Position Error
Used by: GP551
Cause: The lower cleaner tray is not in the locked position.
Remedy: Move the lower cleaner tray to the locked position.
------------------------------
Code: 12050113
Display: 印刷位置无网板
[Conf scr at print pos now]
Used by: GPX,NXTP
Cause: 印刷位置上没有网板。
Remedy: 请在印刷位置上设置网板。
<img src="$LKEY_ERRIMG_MC$/12050113.PNG">
------------------------------
Code: 12050114
Display: Warning! Top Cleaner may damage solder roll
Used by: GP551
Cause: On machines with double squeegees, solder may be present on the screen. During automatic
operation, cleaning of both sides cannot be performed.
Remedy: In Proper data, set the cleaning method to not use the upper cleaning unit.
------------------------------
Code: 12050115
Display: Placing head 1 nozzle has become detached.
Used by: IP3
Cause: The nozzle at placing head 1 has become detached.
Remedy: Remove the detached nozzle from within the machine. Either reattach the nozzle to the head by
hand, or set the nozzle in the nozzle change unit and use the [NOZZLE] -[CHANGE] commands to perform
reattachment.
------------------------------
Code: 12050116
Display: Placing head 2 nozzle has become detached.
Used by: IP3
Cause: The nozzle at placing head 2 has become detached.
Remedy: Remove the detached nozzle from within the machine. Either reattach the nozzle to the head by
hand, or set the nozzle in the nozzle change unit and use the [NOZZLE] -[CHANGE] commands to perform
reattachment.
------------------------------
Code: 12050117
Display: 传感器检测出挡块不可下降错误
Used by: NXTP
Cause: 因为传感器检测出电路板,所以不能降低挡块。
Remedy: 1.请清除电路板。
2.请调整传感器。
<img src="$LKEY_ERRIMG_MC$/12050117.PNG">
------------------------------
Code: 1205012?
Display: Nozzle damage has been detected on head 1.
Used by: NP133,NP134,NP153
Cause: The nozzle bend check sensor at head 1, 13ST has detected a nozzle error. The question mark (?)
indicates the nozzle position. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Replace the nozzle, either manually or using the nozzle change command.
第 493 页