FUJI错误代码查询 - 第497页
Code: 12050195 Display: D2 pallet sensor error. Used by: CP-742ME, CP-742E, CP-752E Cause: A logic error occurred at the D2 pallet UP sensor. The D2 pallet UP sensor (X0A2) and DOWN sensor (X095) are both on. Remedy: Che…
------------------------------
Code: 1205018D
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper UP sensor (X096) failed to switch on.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 1205018E
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper DOWN sensor (X097) failed to switch off.
Remedy: Check the D2-table stopper DOWN sensor.
------------------------------
Code: 1205018F
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper DOWN sensor (X097) failed to switch on.
Remedy: Check the D2-table stopper DOWN sensor.
------------------------------
Code: 12050190
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper UP sensor (X096) failed to switch off.
Remedy: Check the D2-table stopper UP sensor.
------------------------------
Code: 12050191
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error was detected at the D2-table stopper UP/DOWN sensors. The UP sensor (X096) and
the DOWN sensor (X097) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050192
Display: D1 pallet UP error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1 pallet UP sensor (X08C) is on.
Remedy: Lower the D1 pallet.
------------------------------
Code: 12050193
Display: D1 pallet sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D1 pallet UP sensor. The D1 pallet UP sensor (X08C) and DOWN
sensor (X07F) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050194
Display: D2 pallet UP error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1 pallet UP sensor (X0A2) is on.
Remedy: Lower the D2 pallet.
------------------------------
第 496 页
Code: 12050195
Display: D2 pallet sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D2 pallet UP sensor. The D2 pallet UP sensor (X0A2) and DOWN
sensor (X095) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050196
Display: Currently in maintenance mode!
Used by: NP2,QP3
Cause: The part supply unit is currently in maintenance mode.
Remedy: Leave the maintenance mode to start automatic operation.
------------------------------
Code: 12050197
Display: D2 pallet position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D2 pallet UP (X0A2) and DOWN (X095) sensors. Both of these
sensors are off.
Remedy: Lower the D2 pallet.
------------------------------
Code: 12050198
Display: D1 pallet position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: D1 pallet position error.A logic error occurred at the D1 pallet UP (X08C) and DOWN (X07F)
sensors.Both of these sensors are off.
Remedy: Lower the D1 pallet.
------------------------------
Code: 12050199
Display: 温度超范围
Used by: NXTP
Cause: 机内温度超范围。
Remedy: 1)请确认温控单元。2)请确认温度设定是否合理 3)请确认机外温度是否超出下列范围:合理温度度
±5℃。温控单元的温度调节范围为±5度。4)如果温度没有显示,则有可能是控制器出了故障。
<img src="$LKEY_ERRIMG_MC$/12050199.PNG">
------------------------------
Code: 1205019A
Display: 湿度在合适范围外
Used by: NXTP
Cause: 机内湿度在合适范围之外。
Remedy: 1)请调整湿度。
2)请确认湿度设定范围是否合适。
<img src="$LKEY_ERRIMG_MC$/1205019A.PNG">
------------------------------
Code: 1205019B
Display: 清洗剂蓄水盘已满
Used by: NXTP
Cause: 清洗剂蓄水盘已满。
Remedy: 请将被堵塞的清洗剂输送管路打通。
<img src="$LKEY_ERRIMG_MC$/EI0243.png">
------------------------------
Code: 120501A0
第 497 页
Display: A safety relay error occurred.
Used by: NP2,QP3
Cause: Safety relay failed to come on within prescribed time.
Remedy: Check the safety relay input.
------------------------------
Code: 120501A2
Display: Nozzle length error.
Used by: NP2,QP3
Cause: The nozzle is bent, an incorrect nozzle is loaded, the nozzle check sensor is not adjusted correctly
, or the nozzle check position is incorrect.
Remedy: Check the loaded nozzle. If the correct nozzle is loaded, check the nozzle check sensor is
adjusted correctly, or remeasure the nozzle check position.
------------------------------
Code: 120501A3
Display: Nozzle diameter error.
Used by: NP2,QP3
Cause: The nozzle diameter is incorrect.
Remedy: Attach a nozzle with the correct diameter.
------------------------------
Code: 120501B0
Display: 吸件后,吸嘴活塞不能上升。请除去锁定活塞的原因。
Used by: XP141
Cause: 吸嘴活塞有可能锁住。
Remedy: 请试着将吸嘴活塞压住,确认是否能上下顺畅地移动。
------------------------------
Code: 120501B1
Display: 压送后、吸嘴活塞不能上升。请除去锁定活塞的原因。
Used by: XP141
Cause: 吸嘴活塞有可能锁住。
Remedy: 请确认复位气缸上升确认传感器是否正常地动作。
请试着将吸嘴活塞压住,确认是否能上下顺畅地移动。
------------------------------
Code: 120501B2
Display: 复位汽缸动作出错。
Used by: XP141,XP142
Cause: 没有进行复位气缸的上升以及下降的确认。
Remedy: 请确认复位气缸上升确认传感器是否正常地动作。
吸嘴活塞有可能锁住。
请试着将吸嘴活塞压住,确认是否能上下顺畅地移动。
------------------------------
Code: 120501B3
Display: 真空支撑销干扰传感器有反应。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
Cause: 真空支撑销干扰传感器被遮住光线。
Remedy: 请修正吸取位置。
请确认真空支撑销干扰传感器的反应是否异常。
<img src="$LKEY_ERRIMG_MC$/120501B3.PNG">
------------------------------
Code: 120501B4
Display: 热量异常。请确认下列项目。
Used by: XP141,XP241,XP341,XP142,XP242
第 498 页