法操作后还是无法消除异常,则请联系代理店。 ------------------------------ Code: 12050504 Display: Used by: Cause: Remedy: ------------------------------ Code: 12052001 Display: "CHECK SERVO" (CP), "Servo NG" (GL) Used by:…

100%1 / 5282
Used by: NXTP
Cause: 水满检测传感器感应到泄水槽内的积水已满。
Remedy: 请关闭电源后排除泄水槽排水不通畅的问题。
<img src="$LKEY_ERRIMG_MC$/12050450.PNG">
------------------------------
Code: 12050451
Display: 温控温度保险丝烧断
Used by: NXTP
Cause: 放热散热片的温度保险丝因加热异常而烧断。
Remedy: 请关闭机器电源。请确认放热散热片温度过高的原因(过滤器堵塞、风扇故障等)。请更换保险丝。每个散
热片都配有一个保险丝。(请联系售后服务人员)
<img src="$LKEY_ERRIMG_MC$/12050451.PNG">
------------------------------
Code: 12050452
Display: 温控电源异常
Used by: NXTP
Cause: 温控单元的开关式电源出现输出异常。
Remedy: 可能是电源出了故障或者线路连接有问题。请确认电源以及线路。(请联系售后服务人员)
<img src="$LKEY_ERRIMG_MC$/12050452.PNG">
------------------------------
Code: 12050453
Display: 温度传感器异常
Used by: NXTP
Cause: 温度传感器出现了断线、短路。
Remedy: 请确认温度传感器的连线是否有问题。(请联系售后服务人员)
<img src="$LKEY_ERRIMG_MC$/12050453.PNG">
------------------------------
Code: 12050501
Display: Mark read error!(QP301)
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP5,IP3,QP301
Cause: The mark could not be found. The mark size is incorrect, the mark is missing, the bright setting
is not correctly set or some related problem.
Failed to detect the mark.(QP301)
Remedy: Check that the mark size has been input correctly. Check that the bright setting is set properly.
If it is not, reset this using the [VISION], [BRIGHT] and [MARK] commands. Generally, if the mark can be
seen on the monitor, this adjustment is not necessary.
Check the mark size and the FOL carrier supply direction.(QP301)
------------------------------
Code: 12050502
Display: "Check D**"
Used by: IP3
Cause: The maximum number of vision processing recoveries have been performed for a reason other
than component pickup failure.
Remedy: Make sure that the correct component is being picked up. Inspect the tape feeder, and check
the Part data.
------------------------------
Code: 12050503
Display: 影像处理超时
Used by: GPX-C
Cause: 影像处理超时。
Remedy: 有可能是影像信号线出现了接触不良、断线等现象。请先确认影像信号线,然后再重启机器。如果按上述方
第 518 页
法操作后还是无法消除异常,则请联系代理店。
------------------------------
Code: 12050504
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12052001
Display: "CHECK SERVO" (CP), "Servo NG" (GL)
Used by: CP3,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP551,GP6,IP1,NP132.NP133
Cause: A cycle alarm has occurred in a servo system, or a motor's thermal relay has been tripped.
Remedy: Make sure the servo axes are not overloaded. Inspect the connectors and wiring for motors and
servo amps. Press the thermal relay's reset button to cancel the error. If a thermal relay hasbeen tripped,
press the thermal relay's reset button. Turn the machine's power off, then restart the machine.
------------------------------
Code: 12052002
Display: CHECK C AXIS
Used by: CP3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam axis does not reach target position within the set time limit (CP).
Remedy: Check the cam axis.
------------------------------
Code: 12052003
Display: "X REACH ERR" (CP), "Cycle alarm: servo X(X1)" (IP, IP2, GSP, GL),
"CHECK X-AXIS" (CP3), or "Cycle alarm X: Reach" (CP6)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,IP1,IP2,IP3
Cause: A cycle alarm has occurred for servo axis X. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052004
Display: "Y REACH ERR" (CP), "Cycle alarm: servo Y(Y1)" (IP, IP2, GSP, GL),
"CHECK Y-AXIS" (CP3), or "Cycle alarm Y: Reach" (CP6)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP6,GP2,GP3,GP551,IP1,IP2
,IP3
Cause: A cycle alarm has occurred for servo axis Y. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052005
Display: "Q REACH ERR" (CP), "Cycle alarm: servo Q(Q1)" (IP, IP2, GL), or
"CHECK Q-AXIS" (CP3)
Used by: CP3,GL2,GL5,GL541,IP1,IP2,IP3
Cause: A cycle alarm has occurred for servo axis Q. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects. On the CP3, check the meshing
第 519 页
between the rotor and the nozzle.
------------------------------
Code: 12052006
Display: "R REACH ERR" (CP), "CHECK R-AXIS" (CP3)
Used by: CP3
Cause: A cycle alarm has occurred for servo axis R. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects. On the CP3, check the meshing
between the rotor and the nozzle.
------------------------------
Code: 12052007
Display: "D REACH ERR" (CP), "CHECK D-AXIS" (CP3)
Used by: CP3,CP4-1,CP4-2
Cause: A cycle alarm has occurred for servo axis D. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052008
Display: "C REACH ERR" (CP)
Used by:
Cause: A cycle alarm has occurred for servo axis C. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052009
Display: "Cycle alarm: servo Z(Z1)" (IP), "Cycle alarm Z: Reach" (CP6)
Used by: CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: A cycle alarm has occurred for servo axis C. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200A
Display: "Cycle alarm: servo SX" (IP)
Used by: IP1
Cause: A cycle alarm has occurred for servo axis SX.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205200B
Display: "Cycle alarm: servo SY" (IP)
Used by: IP1
Cause: A cycle alarm has occurred for servo axis SY.The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.