FUJI错误代码查询 - 第524页
Used by: IP3,QP132 Cause: The axis moved beyond its limit. Remedy: Check the coordinates in the program and the values in Proper data. ------------------------------ Code: 12052022 Display: Used by: IP3,QP132 Cause: The …
Display: Cycle Alarm DF
Used by: CP5
Cause: The DF axis did not move within the preset time limit.
Remedy: Check that there is no special load on the DF axis.
------------------------------
Code: 1205201A
Display: Cycle Alarm DR
Used by: CP5
Cause: The DR axis did not move within the preset time limit.
Remedy: Check that there is no special load on the DR axis.
------------------------------
Code: 1205201B
Display: "Cycle alarm D1", "Cycle alarm D1: Reach" (CP6)
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP3
Cause: A cycle alarm has occurred for the D1-axis. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Remove any interfering objects.
------------------------------
Code: 1205201C
Display: "Cycle alarm D2", "Cycle alarm D2: Reach" (CP6)
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP3
Cause: A cycle alarm has occurred for the D2-axis. The servo axis did not reach the targeted value
within the expected time. This error may be caused by interference from another object.
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Remove any interfering objects.
------------------------------
Code: 1205201E
Display: "Cycle alarm <R> NC: Reach" (CP6)
Used by: CP6,CP6M,CP65,CP652C,CP642.CP643
Cause: NC-axis rotation could not be completed within the cycle time; if an <R> is displayed, the NC-axis
was being returned (18ST).
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 1205201F
Display: "Cycle alarm <R> FRQ: Reach" (CP6)
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: FRQ-axis rotation could not be completed within the cycle time; if an <R> is displayed, the FQ-
axis was being returned (12ST).
Remedy: Make sure the servo is not overloaded. Inspect the connectors and wiring for the motor and
servo amp. Inspect the servo amp. Remove any interfering objects.
------------------------------
Code: 12052020
Display:
Used by: IP3,QP132
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052021
Display:
第 523 页
Used by: IP3,QP132
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052022
Display:
Used by: IP3,QP132
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052023
Display:
Used by: IP3,QP132
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052024
Display:
Used by: IP3
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052025
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052026
Display:
Used by: IP3
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052027
Display:
Used by: IP3
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052028
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052029
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
第 524 页
------------------------------
Code: 1205202A
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202B
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202C
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202D
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 1205202F
Display:
Used by:
Cause: The axis moved beyond its limit.
Remedy: Check the coordinates in the program and the values in Proper data.
------------------------------
Code: 12052030
Display:
Used by: GSP5
Cause: An MX axis cycle stop has occurred. The servo axis could not reach its tarte in the specified time.
Something interfered with the movement of the axis.
Remedy: Check the load on the servo axis.Check the motor, servo amp connectors and wiring. Remove
any obstacles to movement.
------------------------------
Code: 12052031
Display:
Used by: GSP5
Cause: An MYL axis cycle stop has occurred. The servo axis could not reach its tarte in the specified
time.Something interfered with the movement of the axis.
Remedy: Check the load on the servo axis.Check the motor, servo amp connectors and wiring. Remove
any obstacles to movement.
------------------------------
Code: 12052032
Display:
Used by: GSP5
Cause: An MYR axis cycle stop has occurred. The servo axis could not reach its tarte in the specified
第 525 页