Cause: Either the very fine tool probe does not advance, or it does not retract. Remedy: Adjust the probe. ------------------------------ Code: 12061009 Display: VF Meter Er Used by: CP3 Cause: Data was not returned from…
Used by: QP3
Cause: Deviation (3σ) exceeded 20[gf]. Specified pressure could not be reproduced.
Remedy: Carry out regular placing pressure zero adjustment again.
------------------------------
Code: 12060313
Display:
Used by:
Cause: There is a screen in the backside cleaning position so the collect command cannot be executed.
Remedy: Remove the screen from the backside position and execute the collect command.
------------------------------
Code: 12061001
Display: CHECK HANDLE
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The handle which turns the cam axis is not in its rest position.
Remedy: Return the handle to its original position.
------------------------------
Code: 12061002
Display: CHECK NOZZLE
Used by: CP3,CP4-1,CP4-2,CP4-3
Cause: The nozzle at station 9 is lowered (CP).
Remedy: Return the nozzle to its original position.
------------------------------
Code: 12061003
Display: CHECK 5ST NZL
Used by: CP3
Cause: The nozzle orientation was not returned to 0 deg at station 12 so the machine stopped when it
reached station 5 (CP).
Remedy: Adjust the rotating mechanisms at stations 5 and 12. If the nozzle was rotated during nozzle
change, cut the power and move the nozzle back to 0 deg. by hand.
------------------------------
Code: 12061004
Display: D ORG POS NG
Used by: CP3,CP4-1,CP4-2
Cause: The table is not at the resupply position (CP).
Remedy: Return the table to the resupply position.
------------------------------
Code: 12061005
Display: NOZZLE SKIP1 OVER
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are too many nozzles skipping (CP).
Remedy: Check the nozzles that are skipping.
------------------------------
Code: 12061007
Display: MAX Dno ERROR
Used by:
Cause: The specified device number is too large (CP).
Remedy: Operate in joint mode.
------------------------------
Code: 12061008
Display: VF Probe Er
Used by: CP3
第 597 页
Cause: Either the very fine tool probe does not advance, or it does not retract.
Remedy: Adjust the probe.
------------------------------
Code: 12061009
Display: VF Meter Er
Used by: CP3
Cause: Data was not returned from the very fine tool or from the LCR meter.
Remedy: Check that the connector and the lines have not been cut.
------------------------------
Code: 1206100A
Display: CHECK CAM
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam axis was not returned to the zero position.
Remedy: Using the cam handle, return the cam to the zero position.
------------------------------
Code: 1206100B
Display: Carrier Position Err. IN
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis in position is the Proper data Pallet Position DF
IN plus 500. Inch the axis to a point in this range.
------------------------------
Code: 1206100C
Display: Carrier Position Err. WORK
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis in position is the Proper data Pallet Position DF
IN plus 500. The D axis out position is the Proper data Pallet Position DF OUT minus 500. Inch the axis
to a point in this range.
------------------------------
Code: 1206100D
Display: Carrier Position Err. OUT
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis out position is the Proper data Pallet Position
DF OUT minus 500. Inch the axis to a point in this range.
------------------------------
Code: 1206100E
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: A nozzle has hit the parts in the rejected parts box.
Remedy: Empty the box.
------------------------------
Code: 1206100F
Display:
Used by: CP5
Cause: The Z origin position (Z0) in the machine has changed.
Remedy: Check that the coupling is not loose. If adjustments are necessary, readjust the Z axis.
------------------------------
Code: 12061010
Display: Coolant oil circulat prob.(cp6)
第 598 页
Used by: CP5,CP6M,CP65,CP652C,CP642,CP643
Cause: The quantity of cooling oil is not sufficient. There is a fault in the circulating motor. There is a
fault in the detecting sensor.
Remedy: Switch off the machine power and check if the oil quantity is within specifications. Check the
circulating motor and the detecting sensor.
------------------------------
Code: 12061012
Display: Nzl origin search err stn12.(cp6)
Used by:
Cause: The nozzle origin position cannot be found.
Remedy: If this error occurs often and at random (ie: not always in the same nozzle), check the
adjustment of the origin position sensor. If this error occurs in a specific nozzle, check the clutch section
of this nozzle.
------------------------------
Code: 12061013
Display: Pallet ID Zero Error
Used by: CP652C
Cause: The result of reading the pallet ID of the pallet on the up-elevator was a pallet ID of "0".
Remedy: Use the pallet ID write command to set a proper ID_No. A value from 1 to 255 can be used as a
valid ID_No. Refer to the Operation Manual for information regarding the ID_No write command.
------------------------------
Code: 12061014
Display: "Ref. side clamp mesh error" (CP-642)
Used by: CP642,CP643
Cause: The guiderail on the XY table did not mesh with the guide on the conveyor.
Remedy: Align the XY table guiderail with the guide on the conveyor.
------------------------------
Code: 12061015
Display: "Interfered with backup pin"
Used by: CP642,CP643
Cause: The XY table structure interfered with the backup pin.
Remedy: Change the position of the backup pin.
------------------------------
Code: 12061016
Display: "ST15 nozzle origin error.", "Return nzl hldr to org pos." (CP6/6M)
Used by: CP6,CP6M,CP65,CP642,CP643
Cause: A Station 15 nozzle origin position check failed to confirm the origin.
Remedy: Return the nozzle holder to a position near the origin. (Nozzle disorientation may occur after
continuous production involving 90[deg] rotation.) If this error occurs even though the nozzleholder is at
the origin position, the Station 15 origin position check sensor requires adjustment.
------------------------------
Code: 12061017
Display: ST1:Nozzle up/down error
ST1:UP-lmt sensor OFF
Used by: CP643
Cause: The ST1 cylinder upper limit sensor was OFF even though the stopper has been engaged to
prevent the nozzle at ST1 from descending,after the head at ST20 was a skipped head during D-axis
positioning or D-axis retraction at the start of automatic operation.
Remedy: Check the ST1 stopper and the ST1 cylinder upper limit sensor(X06A)
------------------------------
Code: 12061018