FUJI错误代码查询 - 第61页
Remedy: Set a correct value for "D" in N_data in the production program. ------------------------------ Code: 1101C012 Display: Used by: Cause: The device number in placing sequence data is out of range. This e…
Code: 1101B001
Display: 没有设定***。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 应设定的项目数值时为0,是字符串时为空格。
Remedy: 请设定为适当的数值。
------------------------------
Code: 1101C000
Display:
Used by: IP3
Cause: The sequence Q-axis angle is not a 90 deg.(+-3 deg.)increment, so the reflow sequence cannot be
performed.
Remedy: If the reflow sequence's Q-axis angle is not at 90 deg.(+-3 deg..) placing cannot be performed.
Set "Q" in N_data to a 90 deg. increment or set "RP" in N_data to reflow pass.
------------------------------
Code: 1101C001
Display:
Used by: IP3
Cause: There is no reflow temperature setting specified for the reflow sequence.
Remedy: A reflow temperature setting is necessary for the reflow sequence.
Therefore, set the appropriate sequence in the production program's "R_temp" setting in N_data or set "RP"
in N_data to reflow pass.
------------------------------
Code: 1101C002
Display:
Used by: IP3
Cause: There is no reflow time setting specified for the reflow sequence.
Remedy: A reflow time setting is necessary for the reflow sequence.
Therefore, set the appropriate sequence in the production program's "R_time" setting in N_data or set "RP"
in N_data to reflow pass.
------------------------------
Code: 1101C003
Display:
Used by: IP3
Cause: There is a reflow sequence in the object production program, but the production environment
data name has not been set.
Remedy: A production environment data name is necessary if there is a reflow sequence. Input a
production environment data name in the production program's "58.Reflow_data_name" in Machine_data.
Otherwise, set "RP" in N_data to reflow pass for all sequences.
------------------------------
Code: 1101C010
Display:
Used by: IP3
Cause: The device number in placing sequence data is out of range. This error applies to sequences 1 to
20.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C011
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 21
to 40.
第 60 页
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C012
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 41
to 60.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C013
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 61
to 80.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C014
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 81
to 100.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C015
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 101
to 120.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C016
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 121
to 140.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C017
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 141
to 160.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C018
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 161
to 180.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
第 61 页
Code: 1101C019
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 181
to 200.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C01A
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 201
to 220.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C01B
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 221
to 240.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C01C
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 241
to 260.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C01D
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 261
to 280.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C01E
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 281
to 300.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C01F
Display:
Used by:
Cause: The device number in placing sequence data is out of range. This error applies to sequences 301
to the final sequence.
Remedy: Set a correct value for "D" in N_data in the production program.
------------------------------
Code: 1101C020
Display: