FUJI错误代码查询 - 第610页
Used by: IP1,IP3 Cause: The results of nozzle check indicate that the nozzle which was picked up when the machine operation was cancelled is still in the nozzle station. Remedy: Check the nozzle station. ----------------…
Used by: IP1,IP2,IP3
Cause: Even though the nozzle has not been removed from the station, the nozzle check sensor is not on.
Alternately, the sensor is on for a position in which there is a nozzle in machine memory. When changing
nozzles, the target nozzle is not at the nozzle station.
Remedy: Adjust the sensitivity of the LLN_ORIGIN, LN_ORIGIN, MN_ORIGIN and _SN_ORIGIN sensors.
Alternately, the correct clamp was not used. Check the clamp. Check whether all the nozzles specified in
the production program are all there, and check that the nozzles specified in the program are correct.
------------------------------
Code: 1206200F
Display: Move Nozzle to original point
Used by: IP1
Cause: According to the machine memory a nozzle has not been picked up, but the nozzles are not all
back in their original positions. Alternately, the nozzle has been picked in machine memory but is in
reality not picked up.
Remedy: Remove the nozzle by hand, so that the reality is the same as indicated in the STATUS heading
in the 1st display area. Alternately, press the [NOZZLE COMMAND] function key. To remove the nozzle,
put the I/O setting CHUCK_RELEASE to on, and the nozzle can be removed. Take care not to drop the
nozzle when removing it by hand. To place the nozzle back into its original position, set the I/O setting
NOZZLE_SHUTTER to ON to open the shutters, and OFF to close them.
------------------------------
Code: 12062010
Display: CHECK LOADER
Used by:
Cause: When the Y axis can be inched, and the conveyor notch, loader stopper or reference pin is on,
there is a problem with inching.
Remedy: Turn off the above switches at the I/O board. Except for Y axis inching, this error does not
affect normal operation.
------------------------------
Code: 12062011
Display: Nozzle Shift
Used by: IP1
Cause: During nozzle change, the Y axis nozzle shift detection sensor (left edge or right edge) has been
removed.
Remedy: Check the nozzle left/right edge sensor.
------------------------------
Code: 12062012
Display: CHECK Z
Used by: IP1,IP3
Cause: The Z axis is less than 5 mm over the upper surface of the board (Z0). This could cause
interference in the Y and other axes, so inching cannot be carried out.
Remedy: Inch the Z axis up.
------------------------------
Code: 12062013
Display: CHECK NOZZLE STATION
Used by:
Cause: The nozzle station has shifted to the right. This interferes with Y axis movement, so inching
cannot be carried out.
Remedy: Return the nozzle station to the left. This error applies only to the IP1 shift station.
------------------------------
Code: 12062014
Display: CHECK NOZZLE POSITION
第 609 页
Used by: IP1,IP3
Cause: The results of nozzle check indicate that the nozzle which was picked up when the machine
operation was cancelled is still in the nozzle station.
Remedy: Check the nozzle station.
------------------------------
Code: 12062015
Display: CHECK FEEDER STATION 1(2)
Used by: IP1
Cause: The feeder parts shuttle is advanced.
Remedy: This is interfering with the nozzle so retract the shuttle at the I/O board. For example, if the
feeder at device 20 is advanced, set the OUT 3-20 PARTS_FEEDER20 I/O setting to off. When the display
is 1, this refers to station 1, and if the display is 2, this refers to station 2.
------------------------------
Code: 12062016
Display: 200V NG
Used by:
Cause: When the start button was pressed to start zero setting, the 200V power supply was not on and
zero setting was not carried out.
Remedy: Check the thermals, circuit protectors, etc. to find the reason the power supply is not on.
------------------------------
Code: 12062017
Display: MAIN CONVEYOR POSITION ERROR
Used by: IP1
Cause: The Y table has moved away from its loading position, so the board cannot be loaded or cleared
off. This error occurs after inching, or after an emergency stop, etc.
Remedy: Inch the Y axis to return the table, or use the [LOADER], [PCBSET] or [CLROFF] command
function keys.
------------------------------
Code: 12062018
Display: Please check I/O NOZZLE STATION
Used by:
Cause: Neither of the nozzle station location sensors are on.
Remedy: Adjust either IN2-27 NOZZLE_R_END or IN2-26 NOZZLE_L_END.
------------------------------
Code: 12062019
Display: CHECK PCB SENSOR
Used by:
Cause: The board arrival sensor or the board deceleration sensor is off. Either the sensor is not adjusted
properly, or the sensor is off because of parts or holes on the board.
Remedy: Inspect the board arrival sensor or the board deceleration sensor. If this error occurs due to
parts or holes in the board, continue production.
------------------------------
Code: 1206201A
Display: Please check I/O
Used by:
Cause: On IP machines where the nozzle station shifts, neither the I/O NOZZLE_R_END nor
NOZZLE_L_END setting is on. On IP machines where the nozzle station does not shift, either the I/O
NOZZLE_R_END or NOZZLE_L_END setting is on.
Remedy: On shift style IP machines, one of them should be on, and on non-shift style machines, they
should both be off.
------------------------------
第 610 页
Code: 1206201B
Display: Tray chute not closed
Used by:
Cause: The tray chute is not closed.
Remedy: Close the tray chute.
------------------------------
Code: 1206201C
Display: Rear operation disables inching
Used by:
Cause: When the operation panel is at the rear, inching was attempted on button 3, and could not be
done.
Remedy: Carry out inching with the panel at the front.
------------------------------
Code: 1206201D
Display: Check Nozzle
Used by:
Cause: Inching was attempted with the nozzle lowered.
Remedy: Raise the nozzles and do the inching.
------------------------------
Code: 1206201E
Display: IP2 ERROR
Used by: IP2
Cause: There was an error in IP2 control program processor.
Remedy: If the problem continues after pressing the reset button, contact Fuji.
------------------------------
Code: 1206201F
Display: MTU not Ready
Used by: IP2
Cause: At the MTU, the preset time has been used but there has been no live marker number entered.
There is an alarm on the MTU.
Remedy: Check that the MTU breaker is not off. Check that the MTU cable is connected properly; turn off
the machine and re-boot. If the problem persists, contact Fuji.
------------------------------
Code: 12062020
Display:
Used by: IP3
Cause: The reject parts conveyor could not start moving.
Remedy: Check the reject parts conveyor.
------------------------------
Code: 12062021
Display: LIGHTING TIME UP
Used by: IP2
Cause: The time limit set for the surface to light has been exceeded.
Remedy: Turn off the power and turn it on again.
------------------------------
Code: 12062022
Display: The [X?-Z? INTERLOCK] sensor is off.
Used by: IP-3
Cause: An attempt was made to move the X-axis when a clearance of 7.5 mm
was not present between the tip of the nozzle and the upper surface of the board.
Remedy: Make adjustments to the [X?-Z? INTERLOCK] sensor or ensure that the
第 611 页