sensor wiring is correctly connected. ------------------------------ Code: 12062023 Display: Station ? Nozzle Rest Not at Retract Limit Used by: IP-3 Cause: An attempt was made to move the X-axis even though the nozzle c…

100%1 / 5282
Code: 1206201B
Display: Tray chute not closed
Used by:
Cause: The tray chute is not closed.
Remedy: Close the tray chute.
------------------------------
Code: 1206201C
Display: Rear operation disables inching
Used by:
Cause: When the operation panel is at the rear, inching was attempted on button 3, and could not be
done.
Remedy: Carry out inching with the panel at the front.
------------------------------
Code: 1206201D
Display: Check Nozzle
Used by:
Cause: Inching was attempted with the nozzle lowered.
Remedy: Raise the nozzles and do the inching.
------------------------------
Code: 1206201E
Display: IP2 ERROR
Used by: IP2
Cause: There was an error in IP2 control program processor.
Remedy: If the problem continues after pressing the reset button, contact Fuji.
------------------------------
Code: 1206201F
Display: MTU not Ready
Used by: IP2
Cause: At the MTU, the preset time has been used but there has been no live marker number entered.
There is an alarm on the MTU.
Remedy: Check that the MTU breaker is not off. Check that the MTU cable is connected properly; turn off
the machine and re-boot. If the problem persists, contact Fuji.
------------------------------
Code: 12062020
Display:
Used by: IP3
Cause: The reject parts conveyor could not start moving.
Remedy: Check the reject parts conveyor.
------------------------------
Code: 12062021
Display: LIGHTING TIME UP
Used by: IP2
Cause: The time limit set for the surface to light has been exceeded.
Remedy: Turn off the power and turn it on again.
------------------------------
Code: 12062022
Display: The [X?-Z? INTERLOCK] sensor is off.
Used by: IP-3
Cause: An attempt was made to move the X-axis when a clearance of 7.5 mm
was not present between the tip of the nozzle and the upper surface of the board.
Remedy: Make adjustments to the [X?-Z? INTERLOCK] sensor or ensure that the
第 611 页
sensor wiring is correctly connected.
------------------------------
Code: 12062023
Display: Station ? Nozzle Rest Not at Retract Limit
Used by: IP-3
Cause: An attempt was made to move the X-axis even though the nozzle changer
was not at the retract position.
Remedy: Ensure that the nozzle changer has been retracted and that the sensor
wiring is correctly connected.
------------------------------
Code: 12063001
Display: "Move squeegee to origin position" (GSP), "Move squeegee to printing start position (GP5, GP6)
Used by: GSP2,GSP3,GP2,GP3
Cause: The machine does not know the printing direction because the squeegee is in the middle of a
print stroke.
Remedy: Move the squeegee to either the right or the left origin point.
------------------------------
Code: 12063002
Display: Error: Not Z_axle Original
Used by:
Cause: The frame was not down when either the screen plate notch was to have been released or caught.
Remedy: Lower the frame. Check the lower edges of the frame.
------------------------------
Code: 12063003
Display: Error: Not Y_axle Original
Used by:
Cause: When the frame is to be lowered, the Y axis did not retract to the safety area.
Remedy: Retract the Y axis until the Y axis safety sensor turns on.
------------------------------
Code: 12063004
Display: EXIST CARRING ON M/C CHECK SENSOR
Used by: GSP2,GSP3
Cause: When a screen change is attempted, at least one of the following conditions arose: the frame set
sensor is on, the frame push sensor is on, the frame supply normal sensor is shaded, the frame X axis
sensor is lighted, the right frame X axis sensor is lighted, the left frame X axis sensor is lighted.
Remedy: Check each sensor
------------------------------
Code: 12063005
Display: Screen In Position
Used by: GSP2,GSP3
Cause: In the case where an attempt was made to move the stencil frame to the print position, a stencil
already existed at the print position and thus supply was not possible. The input signal indicating that no
stencil exists inside the frame, was off. (The light beam of the sensor indicating no stencil inside the frame
had not been cut.) (GSP) The lower-limit sensors of the top stencil clamps were all on. (GP6)
Remedy: Remove the stencil frame from inside the frame. Check the sensors.
------------------------------
Code: 12063006
Display: NOT SCREEN ON FRAME
Used by: GSP2,GSP3
Cause: When the machine attempted to remove a screen from the frame, there was no screen there.
With no screen in the frame the input is on. (The light beam is interrupted.)
第 612 页
Remedy: Set a screen in the frame. Check the sensor.
------------------------------
Code: 12063007
Display: NOT SCREEN IN SUPPLY STOCKER
Used by: GSP2,GSP3
Cause: When the machine attempted to remove a screen from the upper stocker, a screen was not there.
Either the screen position shifted, or there was no screen and the sensor input was on (the upper stocker
light beam is interrupted).
Remedy: Confirm that a screen has been set into the stocker. Check the sensor.
------------------------------
Code: 12063008
Display: EXIT SCREEN IN TAKE_OUT STOCKER
Used by: GSP2,GSP3
Cause: A screen was already in the lower stocker when the machine attempted to store a screen. The
screen sensor for the lower stocker is off.
Remedy: Remove the screen from the lower stocker. Check the screen sensor.
------------------------------
Code: 12063009
Display: SCREEN POSITION IS BAD!
Used by: GSP2,GSP3
Cause: When the machine attempted to move the XY robot, at least one of the following conditions arose:
the frame set sensor is on, the frame push sensor is on, the frame supply normal sensor is shaded, the
frame X axis sensor is lighted, the right frame Y axis sensor is lighted, the left frame Y axis sensor is
lighted, the screen exchange in progress sensor is on.
Remedy: Check the position of the screen frame. Check each sensor.
------------------------------
Code: 1206300A
Display: SCREEN CHANGE ERROR
Used by: GSP2,GSP3
Cause: An error occurred during screen change.
Remedy: Refer to the display in the 2nd display area and perform that countermeasure.
------------------------------
Code: 1206300B
Display: 网板补正量在范围之外 (GSP)
Used by: GSP2,GSP3,GPX,NXTP
Cause: 想要进行网板补正,但是脉冲马达的移动量超出了Travel limit 的范围。 补正马达目的地超过了移动范围
(GPX)
Remedy: 请检查程序的定位点坐标。请调整网板框的垫圈。请确认proper的travel_limit_mx ml mr 是否没有为0。
(参考)脉冲马达在零设定完成时的计数器为500。因为网板的补正范围是±5㎜,所以计数器值的0~1000为有效范围
。在GSP-Ⅱ5000 中,脉冲马达的零设定完成时的计数器为1000,另外,因为网板的补正范围是±10㎜,所以计
数器值的0~2000为有效范围。 请确认这些数值和proper的travel_limit_min travel_limit_max 的各MX,ML,MR的
设定。 1.请确认钢板的位置是否正确。
2.请确认电路板的尺寸是否正确。
3.不是在自动运转时,请确认补正马达的固有值MAX,MIN值是否正确。
4.存在可能需要重新测定补正马达原点的情况。(GPX)
<img src="$LKEY_ERRIMG_MC$/1206300B.PNG">
------------------------------
Code: 1206300C
Display: DATA ERROR
Used by:
Cause: There was a data check error on the Handy Terminal.